Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

Strips Comfort 700 is a very discreet multi-function sensor, with a built-in accurate temperature and humidity sensor, an ambient light sensor, 10 year battery life and our unique +Switch to trigger scenarios, its the perfect addition to any room.Strip Comfort 700 can be configured to send temperature, humidity and ambient light reports periodically, or based upon changesfromlast report. It can also calculate and report the average temperature periodically. You can also set Strips Comfort 700 to send alert reports when a set temperature or light level has been reached.Strips Comfort 700 comes with our +Switch slider that can be used to trigger scenarios or activate other devices such as lights or blinds.Strips Comfort 700 supports associations to enable connectivity directly with other Z-Wave Plus devices without requiring a Z-Wave gateway.Z-Wave Plus 700 series sensors bring a wealth of additional valued features such as longer range, low power consumption for an extended battery life and SmartStart technology for instant enrolling. With SmartStart, device inclusion can be initiated automatically by simply removing the included magnets. The Z-Wave gateway then performs the inclusion process in the background without the need for user interaction. 700 Series provides a direct range of 100 meters, an improvement of 60 meters over the 500 series and also includes the industrys best S2 security, providing Strips with the ultimate combination of features for your smart home.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 The Lifeline group, includes all commands that are sent automatically to keep a central controller notified of the status of Strips Comfort 700. This includes the battery level, the temperature and humidity levels, high and low temperature notifications, ambient light level reports and central scene notifications.
2 5 OFF00 (0x00)ON255 (0xFF)This association shall work for both Binary Switch and Timed Switch functions set in configuration parameter 29Slider switch function
3 5 OFF00 (0x00)ON255 (0xFF)Values could be modified using the configuration parameters 33 & 34This association shall work for both Binary Switch and Timed Switch functions set in configuration parameter 29Slider switch function
4 5 Pre-requisite: configuration parameter no. 29Slider switch function set to 1 (Binary Switch)OFF00 (0x00) orThe value set in the configuration parameter 35, Default is Heat Mode On01 (0x01)
5 5 Temperature Value
6 5 High temperature alarm = OFF00 (0x00)Low temperature alarm = ON255 (0xFF)Values could be modified using the configuration parameters 36 & 37
7 5 High ambient light (LUX) level trigger = ON255 (0xFF)Low ambient light (LUX) level trigger = OFF00 (0x00)Values could be modified using the configuration parameters 38 & 39

Configuration Parameters

Parameter 10: High ambient light (LUX) level trigger

The sensor will send a light report when the light rises above this level. Can be used in scenarios to trigger other devices. When enabling parameter 10, parameter 11 must also be set with a lower value, else the trigger stays off
Size: 4 Byte, Default Value: 0

Setting Description
0 Off
20 - 64000 LUX

Parameter 11: Low ambient light (LUX) level trigger

The sensor will send a light report when the light goes below this level. Can be used in scenariosto trigger other devices. When enabling parameter 11, parameter 10 must also be set with a greater value, else the trigger stays off
Size: 4 Byte, Default Value: 0

Setting Description
0 Off
10 - 42000 LUX

Parameter 2: LED alarm event reporting

Turn On or Off LED for specific event indications (ex. alarms)
Size: 1 Byte, Default Value: 1

Setting Description
0 Off
1 - 0 On, but no LED indication for associated nodes (1/5 blinks)
2 - 0 On with LED indications based on success/fail for BOTH the gateway and the associated nodes

Parameter 25: Temperature and Humidity reporting time (Activat

Select the number of minutes between reports (15 mins to 24 hrs)
Size: 2 Byte, Default Value: 60

Setting Description
15 - 1440 Minutes between reports (periodic reporting)

Parameter 26: Temperature change for next report (Activated i

Temperature must change by this value for new a reportDefault: u002220 ( = 2.0 C) or 30 (= 3.0 F for US frequency)u0022
Size: 1 Byte, Default Value: 20

Setting Description
5 - 100 Input value converted to one decimal place [= 0.5 to 10.0 (degree C/F) ]

Parameter 28: Humidity change for next report (Activated in p

Humidity must change by this value for a new report
Size: 1 Byte, Default Value: 5

Setting Description
2 - 10 %

Parameter 29: Slider switch function

Select if the switch should act as a binary switch or a timed switch.
Size: 1 Byte, Default Value: 1

Setting Description
1 - 0 Binary Switch
2 - 0 Timed Switch

Parameter 30: Timed Switch duration

Select the duration that should trigger the opposite state of the Switch (if 2 is selected in parameter 29)
Size: 1 Byte, Default Value: 5

Setting Description
1 - 60 minutes

Parameter 31: Use Multi-Command encapsulation

Send Temperature and Humidity sensor value reports and or Temperature Alarms related reports (Notification Report + Multi-Level Sensor Report + Central Scene Notification) in one message, this saves battery power. Make sure your gateway supports Multi-Command Command Class first.
Size: 1 Byte, Default Value: 0

Setting Description
0 Off
1 - 0 On

Parameter 32: Use Central Scene Notifications

Central Scene Notifications are sent for the Slider Switch state change, High and Low Temperature Alarms and High and Low Ambient Light states. Scenes could be configured in the gateway. Scenes allow multiple devices to be controlled by a single Z-Wave command.
Size: 1 Byte, Default Value: 1

Setting Description
0 Off
1 - 0 On

Parameter 33: Basic Set value sent to Association group 3 when

This parameter defines the value sent to the devices in the Association group 3 (using Basic Command Class).
Size: 1 Byte, Default Value: 255

Setting Description
0 - 255 Basic Set value sent to Association group 3 when the slider switch is on

Parameter 34: Basic Set value sent to Association group 3 when

This parameter defines the value sent to the devices in the Association group 3 (using Basic Command Class).
Size: 1 Byte, Default Value: 0

Setting Description
0 - 255 Basic Set value sent to Association group 3 when the slider switch is off

Parameter 35: Thermostat mode for Association group 4 on Binar

This config parameter defines the value sent to the devices in the Association group 4 (using Thermostat Mode Command Class). Refer the Thermostat modes supported by the associated node
Size: 1 Byte, Default Value: 1

Setting Description
1 - 13 Thermostat mode for Association group 4 when the slider switch is on

Parameter 36: Basic Set value sent to Association group 6 on H

This config parameter defines the value sent to the devices in the Association group 6 (using Basic Command Class)
Size: 1 Byte, Default Value: 0

Setting Description
0 - 255 Basic Set value sent to Association group 6 on High Temperature Alarm

Parameter 37: Basic Set value sent to Association group 6 on L

This config parameter defines the value sent to the devices in the Association group 6 (using Basic Command Class)
Size: 1 Byte, Default Value: 255

Setting Description
0 - 255 Basic Set value sent to Association group 6 on Low Temperature Alarm

Parameter 38: Basic Set value sent to the Association group 7

This config parameter defines the value sent to the devices in the Association group 7 (using Basic Command Class)
Size: 1 Byte, Default Value: 255

Setting Description
0 - 255 Basic Set value sent to the Association group 7 on High ambient light level report

Parameter 39: Basic Set value sent to the Association group 7

This config parameter defines the value sent to the devices in the Association group 7 (using Basic Command Class)
Size: 1 Byte, Default Value: 0

Setting Description
0 - 255 Basic Set value sent to the Association group 7 on Low ambient light level report

Parameter 4: Temperature & Humidity reporting

Select temperature and humidity sensor reporting
Size: 1 Byte, Default Value: 1

Setting Description
0 Off
1 - 0 On. Sends temperature/humidity based on difference from last reported value (set in config parameters 26 and 28)
2 - 0 On. Timed reporting of the actual temperature and the actual humidity value (set time in config parameter 25)
3 - 0 On. Timedreporting of the average temperature value between reports. Will also send the actual humidity value (set time in config parameter 25)

Parameter 5: Temperature unit

Select the temperature unitDefault:0 (Except US frequency) or 1 (US frequency)
Size: 1 Byte, Default Value: 1

Setting Description
0 Celcius
1 - 0 Fahrenheit

Parameter 6: Temperature alarms

Turn On or Off temperature alarm (Thealarms are not affected byparameters 4, 25 or 26)
Size: 1 Byte, Default Value: 0

Setting Description
0 Off
1 - 0 On

Parameter 7: High temperature alarm level

Select high temperature alarm levelu0022-20 to +80 (degree C) or-4 to +176 (degree F) (US frequency)u0022Default:u002240 Cor104 F (US frequency)u0022
Size: 2 Byte, Default Value: 104

Setting Description
-4 - 176 (degree F) (US frequency)

Parameter 8: Low temperature alarm level

Select low temperature alarm levelu0022-20 to +60 (degree C) or -4 to +140 (degree F) (US frequency)u0022Default: u00225 Cor41 F (US frequency)u0022
Size: 2 Byte, Default Value: 41

Setting Description
-4 - 140 (degree F) (US frequency)

Parameter 9: Ambient light reporting

Ambient light report settings. Using a filter (low-pass) ishighly recommended to avoid large amounts of reports influctuating lights.
Size: 1 Byte, Default Value: 8

Setting Description
0 Off
1 Reporting visual changes without filter (This configuration will affect the sensor battery life if placed where light fluctuates significantly)
2 - 8 Filter length. 2 is the fastest filter allowing quick responses. 8 is a slower filter setting and will give the longest battery life

Technical Data

Hardware Platform ZGM130
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 1 FW: 5.08
Z-Wave Version 7.13.7
Certification ID ZC12-21120327
Z-Wave Product Id 0x019A.0x0004.0x000C
Z-Wave Scene Type Central Scene
Firmware Updatable Updatable by Consumer by RF
Color White
Frequency XXfrequency
Maximum transmission power XXantenna
Notification Sensor