This is a
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
The Leedarson door window sensor is designed for use with scenes in home automation and security systems, the door window sensor lets you know when door or windows is opened and can trigger different actions in response to that open action (or close action).
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | New Group 1 is a Lifeline group |
2 | 5 | New Group 2 is a On/Off control function |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Set the range about magnetic field Range:0-the range of parameter 0x02 is 0x00000001-0x00004B00, the range of parameter 0x03 is 0x00000001-0x00002300.1- the range of parameter 0x02 is 0x00000001-0x0002EE00, the range of parameter 0x03 is 0x00000001-0x00015E00. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | 0-the range of parameter 0x02 is 0x00000001-0x00004B00 and the range of parameter 0x03 is 0x00000001-0x00002300. 1- the range of parameter 0x02 is 0x00000001-0x0002EE00 and the range of parameter 0x03 is 0x00000001-0x00015E00. |
This parameter defines a battery level as the low battery.Range:0x05-0x32 Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
5 - 50 | 0x0A defines the low battery level. 0x05 means that device will send a low level alarm report when the battery levle is less than 5%. 0x32 means that device will send a low level alarm report when the battery levle is less than 50%. |
Enable/Disable BASIC SET command 0Disable.1Enable. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | parameter 14 will disable/enable the basic set command when it is triggered. the value 0 means that sensor will not send basic set command when the sensor is triggered, value 1 means that the sensor willl send basic set command when it is triggered. |
Door Sensor reverse its value of BASIC SET when the magnet is triggered. 0 -Send BASIC SET VALUE = 0xFF/0x00 to nodes associated with group 2 when door is opened/closed.1 Send BASIC SET VALUE = 0/255 to nodes associated with group 2 when door is opened/closed. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | 0 -Send BASIC SET VALUE = 0xFF/0x00 to nodes associated with group 2 when door is opened/closed. 1 Send BASIC SET VALUE = 0/255 to nodes associated with group 2 when door is opened/closed. |
7210OPSet the average magnetic field in utRange: 0x00000001-0x00004B00or 0x00000001-0x0002EE00 Size: 4 Byte, Default Value: 640
Setting | Description |
---|---|
1 - 19200 | the average magnetic field.0x00000001 means that the magnetic field is 1 ut, 0x0002EE00 means that the magnetic field is192000 ut |
Enable/Disable Bypass mode 0Enable.1Disable. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 1 | parameter 20 disable/enable the bypass mode. the value 0 means that sensor will enter a bypass mode when the bypass button is pressed, value 0 means that sensor will not enter bypass mode when the bypass button is pressed |
The interval time the Door Sensor reports the Multilevel Sensor Report to association group1 in minutes.0x0F-0xFF Size: 1 Byte, Default Value: 15
Setting | Description |
---|---|
15 - 127 | parameter 0x21 assign the time the sensor send the temperature report to associated node in minute. For example0x10 means that sensor will send a temperature report every 14 mins |
Enable/Disable configuration set 0Enable.1Disable. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | parameter 0xFE disable/enable the configuration set function. value 0 means that any configuration set will be disabled, value 1 means that configuration set will be enbale,you can change the values of the configration parameters |
Set the offset about magnetic field Range: 0x00000001-0x00002300or 0x00000001-0x00015E00 Size: 4 Byte, Default Value: 200
Setting | Description |
---|---|
1 - 8960 | the offset of the magnetic field.0x00000001 means that the magnetic field is 1 ut, 0x0002EE00 means that the magnetic field is89600 ut |
Hardware Platform | ZGM130 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 1 FW: 1.33 |
Z-Wave Version | 7.12.2 |
Certification ID | ZC12-21090309 |
Z-Wave Product Id | 0x0300.0x0301.0x0041 |
Security V2 | S2_UNAUTHENTICATED ,S2_AUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |