This is a
This in-wall dual relay switch module is a transceiver which This in-wall dual relay switch module is a transceiver which is a Z-Wave PlusTM enabled device and is fully compatible is a Z-Wave PlusTM enabled device and is fully compatible with any Z-WaveTM enabled network. Mini size design let with any Z-WaveTM enabled network. Mini size design let the module can easily hide itself into the wall box and that the module can easily hide itself into the wall box and that will be good for the house decoration.will be good for the house decoration. There are many kind of application by using the module to There are many kind of application by using the module to switch AC power On and Off, one main application is the switch AC power On and Off, one main application is the light control. The new smart relay calibration technology light control. The new smart relay calibration technology can reduce the inrush current caused by the load and let the can reduce the inrush current caused by the load and let the module work perfectly with many kind of light like module work perfectly with many kind of light like incandescent, fluorescent and LED light.incandescent, fluorescent and LED light. This in-wall switch module is able to detect Instant power This in-wall switch module is able to detect Instant power wattage and overload current (7.5A with resistive load) of wattage and overload current (7.5A with resistive load) of connected light or appliances. When detecting overload connected light or appliances. When detecting overload state, the Module will be disabled and its On/Off button will state, the Module will be disabled and its On/Off button will be lockout of which LED will flash quickly. However, be lockout of which LED will flash quickly. However, disconnect and re-connect the Module will reset its overload disconnect and re-connect the Module will reset its overload condition to normal status. condition to normal status.
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Group1 is called Lifeline which support SWITCH_BINARY_REPORT METER_REPORTNOTIFICATION_REPORTINDICATOR_REPORT and DEVICE_RESET_LOCALLY_NOTIFICATION. |
2 | 5 | For group 2, the Switch will report ON/OFF status of Relay1. |
3 | 5 | For group 3, the Switch will report ON/OFF status of Relay2. |
4 | 5 | For group 4, the Switch will report Instant Power Consumption (Watt) and Accumulated Power Consumption (KWh) of Relay1. |
5 | 5 | For group 5, the Switch will report Instant Power Consumption (Watt) and Accumulated Power Consumption (KWh) of Relay2. |
If the setting is configured for 1hour (set value =720), the PAN30 will report its instant power consumption every 1 hour to the node of correspond Group.The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr).If the setting value is 0, the auto report function ofmeter Watt will be disabled. Size: 2 Byte, Default Value: 720
Setting | Description |
---|---|
0 | The auto report function of meter Watt will be disabled. |
1 - 32767 | 720*5s=3600s= 1 hour |
If the setting is configured for 1hour (set value =6), the PAN30 will report its Accumulated Power Consumption (KW/h) every 1 hour to the node of correspond Group. The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days).If the setting value is 0, the auto report function of meter KWh will be disabled. Size: 2 Byte, Default Value: 6
Setting | Description |
---|---|
0 | The auto report function of meter KWh will be disabled. |
1 - 32767 | 6*10min= 1 hour |
This is a warning when the current of load over the preset threshold value, if the setting value is 750, when the load current of Relay1 or Relay2 over this value, PAN30 will send current meter report to the node of correspond Group, the Range of the setting value is from 10 to 750, and the default value is 750. Size: 2 Byte, Default Value: 750
Setting | Description |
---|---|
10 - 750 | 750*0.01A = 7.5A |
This is a warning when the KWh of load over the preset threshold value, If the setting value is 10000, when the Accumulated Power Consumption of Relay1 or Relay2 over this value, PAN30 will send KWh Meter Report command to the node of correspond Group, minimum value is 1KWh and default value is 10000 kWh. Size: 2 Byte, Default Value: 10000
Setting | Description |
---|---|
1 - 10000 | 1KWh ~ 10000KWh |
Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge-Toggle mode, default value is Edge mode. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 - 0 | Edge mode |
2 - 0 | Pulse mode |
3 - 0 | Edge-Toggle mode |
Whenever the AC power return from lost, PAN30 will restore the switch state which could be SWITCH OFFLAST SWITCH STATESWITCH ON. The default setting is LAST SWITCH STATE. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Switch off |
1 - 0 | Last switch state |
2 - 0 | Switch on |
It will trigger a Watt report when the variation of watt value is over the preset percentage. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | The function of Watt differential report will be disabled. |
1 - 0 | 5% |
2 - 0 | 10% |
3 - 0 | 15% |
4 - 0 | 20% |
Hardware Platform | ZGM130 |
Device Type | Binary Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.01 |
Z-Wave Version | 7.15.1 |
Certification ID | ZC12-21070259 |
Z-Wave Product Id | 0x013C.0x0001.0x0077 |
Firmware Updatable | Updatable by Consumer by RF |
Color | White |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |