Quickstart

This is a secure Binary Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

This in-wall dual relay switch module is a transceiver which This in-wall dual relay switch module is a transceiver which is a Z-Wave PlusTM enabled device and is fully compatible is a Z-Wave PlusTM enabled device and is fully compatible with any Z-WaveTM enabled network. Mini size design let with any Z-WaveTM enabled network. Mini size design let the module can easily hide itself into the wall box and that the module can easily hide itself into the wall box and that will be good for the house decoration.will be good for the house decoration. There are many kind of application by using the module to There are many kind of application by using the module to switch AC power On and Off, one main application is the switch AC power On and Off, one main application is the light control. The new smart relay calibration technology light control. The new smart relay calibration technology can reduce the inrush current caused by the load and let the can reduce the inrush current caused by the load and let the module work perfectly with many kind of light like module work perfectly with many kind of light like incandescent, fluorescent and LED light.incandescent, fluorescent and LED light. This in-wall switch module is able to detect Instant power This in-wall switch module is able to detect Instant power wattage and overload current (7.5A with resistive load) of wattage and overload current (7.5A with resistive load) of connected light or appliances. When detecting overload connected light or appliances. When detecting overload state, the Module will be disabled and its On/Off button will state, the Module will be disabled and its On/Off button will be lockout of which LED will flash quickly. However, be lockout of which LED will flash quickly. However, disconnect and re-connect the Module will reset its overload disconnect and re-connect the Module will reset its overload condition to normal status. condition to normal status.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Group1 is called Lifeline which support SWITCH_BINARY_REPORT METER_REPORTNOTIFICATION_REPORTINDICATOR_REPORT and DEVICE_RESET_LOCALLY_NOTIFICATION.
2 5 For group 2, the Switch will report ON/OFF status of Relay1.
3 5 For group 3, the Switch will report ON/OFF status of Relay2.
4 5 For group 4, the Switch will report Instant Power Consumption (Watt) and Accumulated Power Consumption (KWh) of Relay1.
5 5 For group 5, the Switch will report Instant Power Consumption (Watt) and Accumulated Power Consumption (KWh) of Relay2.

Configuration Parameters

Parameter 1: Watt Meter Report Period

If the setting is configured for 1hour (set value =720), the PAN30 will report its instant power consumption every 1 hour to the node of correspond Group.The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr).If the setting value is 0, the auto report function ofmeter Watt will be disabled.
Size: 2 Byte, Default Value: 720

Setting Description
0 The auto report function of meter Watt will be disabled.
1 - 32767 720*5s=3600s= 1 hour

Parameter 2: KWH Meter Report Period

If the setting is configured for 1hour (set value =6), the PAN30 will report its Accumulated Power Consumption (KW/h) every 1 hour to the node of correspond Group. The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days).If the setting value is 0, the auto report function of meter KWh will be disabled.
Size: 2 Byte, Default Value: 6

Setting Description
0 The auto report function of meter KWh will be disabled.
1 - 32767 6*10min= 1 hour

Parameter 3: Threshold of current for Load Caution

This is a warning when the current of load over the preset threshold value, if thesetting value is 750, when the load current of Relay1 or Relay2 over this value, PAN30 will send current meter report to the node of correspond Group, the Range of the setting value is from 10 to 750, and the default value is 750.
Size: 2 Byte, Default Value: 750

Setting Description
10 - 750 750*0.01A = 7.5A

Parameter 4: Threshold of KWh for Load Caution

This is a warning when the KWh of load over the preset threshold value, If the setting value is 10000, when the Accumulated Power Consumption of Relay1 or Relay2 over this value, PAN30 will send KWh Meter Report command to the node of correspond Group, minimum value is 1KWh and default value is 10000 kWh.
Size: 2 Byte, Default Value: 10000

Setting Description
1 - 10000 1KWh ~ 10000KWh

Parameter 5: External switch mode

Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge-Toggle mode, default value is Edge mode.
Size: 1 Byte, Default Value: 1

Setting Description
1 - 0 Edge mode
2 - 0 Pulse mode
3 - 0 Edge-Toggle mode

Parameter 6: Restore switch state mode

Whenever the AC power return from lost, PAN30 will restore the switch state which could be SWITCH OFFLAST SWITCH STATESWITCH ON. The default setting is LAST SWITCH STATE.
Size: 1 Byte, Default Value: 1

Setting Description
0 Switch off
1 - 0 Last switch state
2 - 0 Switch on

Parameter 7: Watt differential report mode

It will trigger a Watt report when the variation of watt value is over the preset percentage.
Size: 1 Byte, Default Value: 1

Setting Description
0 The function of Watt differential report will be disabled.
1 - 0 5%
2 - 0 10%
3 - 0 15%
4 - 0 20%

Technical Data

Hardware Platform ZGM130
Device Type Binary Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.01
Z-Wave Version 7.15.1
Certification ID ZC12-21070253
Z-Wave Product Id 0x013C.0x0001.0x0077
Firmware Updatable Updatable by Consumer by RF
Color White
Frequency XXfrequency
Maximum transmission power XXantenna
Binary Switch