This is a
This product can be operated in any Z-Wave network with other Z-Wave Plus certified devices from other manufacturers. This product is a Multipurpose Sensor, it have door/window sensor and Temperature Humidity sensor. This product is a battery power ,It's sleep most of the time.MSE30Z is a security enabled Z-Wave Plus device. A security Enabled Z-Wave Plus Controller must be used in order to fully utilize the product.
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 3 | Z-Wave Lifeline |
2 | 5 | Notification Access Control |
3 | 5 | Notification Heat Alarm |
4 | 5 | Notification Heat Alarm |
5 | 5 | Notification Weater |
6 | 5 | Notification Weater |
When battery level exceedsthreshold, the unit need to report to hub. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
1 - 20 | Battery report threshold % |
Humidity Upper Watermark value Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 100 | Humidity Upper Watermark value |
Humidity Lower Watermark value Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 100 | Humidity Lower Watermark value |
Switch the unit of Temperature report Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Celsius |
1 | Fahrenheit |
Association Group 2 Setting Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable |
1 | Send Basic SET 0xFF when Magnet is away,and send Basic SET 0x00 when Magnet is near |
2 | Send Basic SET 0x00 when Magnet is away,and send Basic SET 0xFF when Magnet is near. |
3 | Only send Basic SET 0xFF when Magnet is away. |
4 | Only send Basic SET 0x00 when Magnet is near. |
5 | Only send Basic SET 0x00 when Magnet is away. |
6 | Only send Basic SET 0xFF when Magnet is near |
Setting the threshold for low battery alarm report. Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
5 - 20 | Low battery alarm report threshold % |
Parameter defines state of the sensor when the magnet closes the reed Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | door/window closed when magnet closes the reed |
1 | door/window opened when magnet closes the reed |
Delay in seconds when door closed Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 3600 | Door close send command time |
Delay in seconds when door opened Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 3600 | Door open send command time |
Minimum Temperature change to report Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 - 9 | Temperature reportthreshold |
Minimum humidity change to report Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
5 - 20 | Humidityreport threshold |
Temperature Upper Watermark value Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 50 | Temperature Upper Watermark value |
Temperature Lower Watermark value Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 50 | Temperature Lower Watermark value |
Hardware Platform | ZGM130 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 1 FW: 1.00 |
Z-Wave Version | 7.13.9 |
Certification ID | ZC12-21070245 |
Z-Wave Product Id | 0x0312.0x0713.0xD100 |
Firmware Updatable | Updatable by Consumer by RF |
Color | White |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |