Quickstart

This is a secure Multilevel Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The device should only need two wires for dimming, easy to install. This device is a security enabled Z-Wave Plus product that uses encrypted Z-Wave Plus messages to communicate to other security enabled Z-Wave Plus products. Z-Wave enabled devices displaying the Z-Wave logo can also be used with this device regardless of the manufacturer, and this device can also be used in other manufacturers Z-Wave enabled networks.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 1. Grouping 1 Lifeline (Maximum 5 nodes). 2. MULTILEVEL_SWITCH_REPORT When on or ostate has been changed, it will send Multilevel SwitchReport to the nodes of Grouping 1. 3. NOTIFICATION_REPORT When overload occurred. 4. DEVICE_RESET_LOCALLY_NOTIFICATION When PAD15 isreset manually, it will send DEVICE_RESET_LOCALLY_NOTIFICATION to the nodes of group 1.

Configuration Parameters

Parameter 1: Switch set

To select connected switch function.Setting value:0: Only S1 is effective1: Both S1 and S2 are effective.2: S1 dimmer upS2 dimmer down
Size: 1 Byte, Default Value: 1

Setting Description
0 0: Only S1 is e ective
1 1: Both S1 and S2 are e ective.
2 2: S1 dimmer up S2 dimmer down

Parameter 2: Power-on recovery status set

To set dimmer level when AC power on.Setting value:0: OFF-0%1: ON-last level2: ON-100%
Size: 1 Byte, Default Value: 0

Setting Description
0 0: OFF-0%
1 1: ON-last level
2 2: ON-100%

Parameter 3: RF report set

To set if device send Multilevel Switch report to gateway when dimming finished.Setting value:1: report ON0: report OFF
Size: 1 Byte, Default Value: 1

Setting Description
0 0: report OFF
1 1: report ON

Parameter 4: Maximum level

To set dimming level maximum value. Dimming level will not over the setting value. Setting value:Cannot be lower than the Minimum level
Size: 1 Byte, Default Value: 99

Setting Description
1 - 99 1~99 : 1% ~ 99%

Parameter 5: Minimum level

To set dimming level minimum value. Dimming level will directly go to 0% when dimming value is lower than the setting value.Setting value:Cannot be higher than the Maximum level
Size: 1 Byte, Default Value: 0

Setting Description
0 - 98 0~98 : 0% ~ 98%

Parameter 6: Basic duration set

Unit: secondTo set dimming finished duration time when physical switch used.Ex: When setting is 2, it will take 2 seconds from switch on action to dimming finished.
Size: 1 Byte, Default Value: 2

Setting Description
0 - 127 Unit: second ,0 ~127second

Technical Data

Hardware Platform ZGM130
Device Type Multilevel Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.01
Z-Wave Version 7.13.5
Certification ID ZC12-21070243
Z-Wave Product Id 0x013C.0x0005.0x007e
Firmware Updatable Updatable by Consumer by RF
Color White
Frequency XXfrequency
Maximum transmission power XXantenna
Multilevel Switch