This is a
The device should only need two wires for dimming, easy to install. This device is a security enabled Z-Wave Plus product that uses encrypted Z-Wave Plus messages to communicate to other security enabled Z-Wave Plus products. Z-Wave enabled devices displaying the Z-Wave logo can also be used with this device regardless of the manufacturer, and this device can also be used in other manufacturers Z-Wave enabled networks.
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | 1. Grouping 1 Lifeline (Maximum 5 nodes). 2. MULTILEVEL_SWITCH_REPORT When on or ostate has been changed, it will send Multilevel SwitchReport to the nodes of Grouping 1. 3. NOTIFICATION_REPORT When overload occurred. 4. DEVICE_RESET_LOCALLY_NOTIFICATION When PAD15 isreset manually, it will send DEVICE_RESET_LOCALLY_NOTIFICATION to the nodes of group 1. |
To select connected switch function.Setting value:0: Only S1 is effective1: Both S1 and S2 are effective.2: S1 dimmer upS2 dimmer down Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | 0: Only S1 is e ective |
1 | 1: Both S1 and S2 are e ective. |
2 | 2: S1 dimmer up S2 dimmer down |
To set dimmer level when AC power on.Setting value:0: OFF-0%1: ON-last level2: ON-100% Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0: OFF-0% |
1 | 1: ON-last level |
2 | 2: ON-100% |
To set if device send Multilevel Switch report to gateway when dimming finished.Setting value:1: report ON0: report OFF Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | 0: report OFF |
1 | 1: report ON |
To set dimming level maximum value. Dimming level will not over the setting value. Setting value:Cannot be lower than the Minimum level Size: 1 Byte, Default Value: 99
Setting | Description |
---|---|
1 - 99 | 1~99 : 1% ~ 99% |
To set dimming level minimum value. Dimming level will directly go to 0% when dimming value is lower than the setting value.Setting value:Cannot be higher than the Maximum level Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 98 | 0~98 : 0% ~ 98% |
Unit: secondTo set dimming finished duration time when physical switch used.Ex: When setting is 2, it will take 2 seconds from switch on action to dimming finished. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 - 127 | Unit: second ,0 ~127second |
Hardware Platform | ZGM130 |
Device Type | Multilevel Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.01 |
Z-Wave Version | 7.13.5 |
Certification ID | ZC12-21070243 |
Z-Wave Product Id | 0x013C.0x0005.0x007e |
Firmware Updatable | Updatable by Consumer by RF |
Color | White |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |