LED light inficator
The LED light indicates the different modes of the PSE04
Without Node ID - Under normal operation, when the PSE04 has not been allocated a node ID, the LED light will flash on and off alternately at 0.5 second intervals. By pressing the On/Off button, LED light will stop flashing temporarily.
Learning - Slow flashes once when learning is successful.
Alarm Trigger - All LED flashes until trigger off.
Reset to factory default | 1. Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4th pressed, and the LED will light ON.
2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. Otherwise, the LED will flash once.
3. IDs are excluded and all settings will reset to factory default. |
Inclusion | 1. Have Z-WaveTM Controller entered inclusion mode.
2. Pressing tamper key three times within 1.5 seconds to enter the inclusion mode.
3. After add successful, the LED will light ON 1 second |
Exclusion | 1. Have Z-WaveTM Controller entered exclusion mode.
2. Pressing tamper key three times within 1.5 seconds to enter the exclusion mode.
3. Node ID has been excluded. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | 1. Set the Z-WaveTM Controller into the firmware update mode.
2. Choose the hex file to update the firmware.
3. Wait 10~15 minutes for completing the OTA process.
4. Result of OTA will show in Z-Wave™ Controller log. |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Lifeline |
Size: 1 Byte, Default Value: 30
Setting | Description |
---|---|
1 - 255 | The interval time for auto report each tick. |
Size: 1 Byte, Default Value: 6
Setting | Description |
---|---|
1 - 127 | Play sound duration, 1 tick is 30 seconds. |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Disable Trigger Alarm |
2 | Disable Sound. Only using optical alarm. |
4 | Temperature Unit set to Fahrenheit |
Size: 1 Byte, Default Value: 12
Setting | Description |
---|---|
1 - 127 | The interval time for auto report the temperature. |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 255 | The temperature differential to report. Steps 1°C |
Size: 1 Byte, Default Value: 12
Setting | Description |
---|---|
0 - 255 | The interval time for auto report the battery level. |
Add Sound Level 1, 2 or 3 with the desired sound.
z.B.: Sound Level 1 (1) + Sound Police (48) = Sound Police Level 1 (49)
Size: Byte, Default Value:
Setting | Description |
---|---|
1 | Sound Level 1 |
2 | Sound Level 2 |
3 | Sound Level 3 |
16 | Sound: Fire |
32 | Sound: Ambulance |
48 | Sound: Police |
64 | Sound: Alarm |
80 | Sound: Ding Dong |
96 | Sound: Beep |
Dimensions | 170 x 48 x 30 mm |
Weight | 205 gr |
Hardware Platform | ZGM130 |
EAN | 4713698577575 |
IP Class | IP IP 44 |
Voltage | 6 V |
Battery Type | 4 * AA LR6 |
Firmware Version | 01.02 |
Z-Wave Version | 07.0f |
Certification ID | ZC12-21060239 |
Z-Wave Product Id | 0x013c.0x0004.0x0084 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |