Quickstart

This is a secure Binary Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The Square D 15 Amp Z-Wave Plus Energy Monitoring Plug-In Duplex Receptacle is the professionals choice for secure reliable lighting control.Easily upgrade a standard receptacle to offer control, excellent for temporary applications like Christmas lighting.Perfect for monitoring energy usage of the device plugged into the controlled outlet.It works with any Z-Wave hub and can be grouped with up to 5 other Z-Wave Plus devices.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Members of this group will receive unsolicited messages related to the status of thePlug.
2 5 Sends Basic Set to associated devices, when Short press the Program Button 2 times.

Configuration Parameters

Parameter 1: LED indicator Status

Synchronization of load power and LED indicator.
Size: 1 Byte, Default Value: 1

Setting Description
0 Power On, LED Off; Power Off, LED On
1 Power On, LED On;Power Off, LED Off

Parameter 2: Delayed OFF Time

Delay off means when users pressbutton to turn off the load,theres a reaction time.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 240 Delay off means when users press button to turn off the load, theres a reaction time.

Parameter 3: Power On Status


Size: 1 Byte, Default Value: 1

Setting Description
1 Off
2 On
3 Last State

Parameter 4: Child Lockout Enable

Child lockout feature can enabled anddisabled local control.
Size: 1 Byte, Default Value: 0

Setting Description
0 Disable
1 Enable

Technical Data

Hardware Platform ZGM130
Device Type Binary Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.05
Z-Wave Version 7.13.6
Certification ID ZC12-21050231
Z-Wave Product Id 0x0447.0x000E.0x1108
Z-Wave Scene Type Central Scene
Frequency XXfrequency
Maximum transmission power XXantenna
Binary Switch