Quickstart

This is a secure Binary Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

FEATURES:- Manual or Z-Wave on/off control with instant status updates- NEW: 700 series Z-Wave chip for better range and faster control- Simple Direct 3-Way: connect with existing on/off switches in 3-way, 4-way, and 5-way set-ups, no add-on needed- Scene control: trigger actions with multi-tap (select hubs only)- Smart bulb mode: disable relay and control the light via Z-Wave- Remembers and restores on/off status after power failure- NEW: discreet LED indicator for easy set-up and troubleshooting- Works with LED and incandescent bulbs (dont use with tubes)

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 3 Lifeline communication with the primary controller with basic reports.
2 5 Basic set commands for on/off control of other Z-Wave devices in the network.

Configuration Parameters

Parameter 1: On/Off Toggle Orientation

Choose if you want to turn the light on or turn the light off when you toggle up the switch.
Size: 1 Byte, Default Value: 0

Setting Description
0 Toggle up turns the light on, toggle down turns it off (default)
1 Toggle up turns the light off, toggle down turns it on
2 Toggle any direction to turn the light on/off (change state)

Parameter 10: Enable/Disable Scene Control

Enable or disable scene control functionality for quick double tap triggers.
Size: 1 Byte, Default Value: 0

Setting Description
0 scene control disabled (default)
1 scene control enabled

Parameter 13: Smart Bulb Mode Behavior

Set reporting behavior for disabled physical control.
Size: 1 Byte, Default Value: 0

Setting Description
0 switch reports on/off status and change LED indicator state even if physical and Z-Wave control is disabled (default).
1 switch doesn't report on/off status or change LED indicator state when physical (and Z-Wave) control is disabled.

Parameter 16: Association Reports

Choose how the switch reports its status back to the hub.
Size: 1 Byte, Default Value: 1

Setting Description
0 Binary switch report for Z-Wave control, basic set report for toggle (physical) control
1 binary switch report for both Z-Wave and toggle control (default)

Parameter 2: LED Indicator

Choose how to use the LED indicator.
Size: 1 Byte, Default Value: 0

Setting Description
0 LED indicator is on when switch is off, LED indicator is off when switch is on (default)
1 LED indicator is on when switch is on, LED indicator is off when switch is off
2 LED indicator is always OFF
3 LED indicator is always ON

Parameter 3: Auto Turn-Off Timer

Use this parameter to enable or disable the auto turn-off timer function (the time after which you want the switch to automatically turn off once it has been turned on).
Size: 4 Byte, Default Value: 0

Setting Description
0 timer disabled
1 - 65535 minutes

Parameter 5: Auto Turn-On Timer

Use this parameter to enable or disable the auto turn-on timer function (the time after which you want the switch to automatically turn on once it has been turned off).
Size: 4 Byte, Default Value: 0

Setting Description
0 timer disabled
1 - 65535 minutes

Parameter 8: On Off Status After Power Failure

Set the on off status for the switch after power failure.
Size: 1 Byte, Default Value: 2

Setting Description
0 forced to OFF (regardless of state prior to power outage
1 forced to ON (regardless of state prior to power outage)
2 remembers and restores on/off status after power failure (default)

Technical Data

Hardware Platform ZGM130
Device Type Binary Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.00
Z-Wave Version 7.13.6
Certification ID ZC12-21050228
Z-Wave Product Id 0x027A.0x7000.0xA003
Firmware Updatable Updatable by Consumer by RF
Neutral Wire Required ok
Color White
Electric Load Type IncandescentLED
Z-Wave Scene Type Central Scene
Frequency XXfrequency
Maximum transmission power XXantenna
Binary Switch