This is a
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
FEATURES:- Manual or Z-Wave on/off control with instant status updates- NEW: 700 series Z-Wave chip for better range and faster control- Simple Direct 3-Way: connect with existing on/off switches in 3-way, 4-way, and 5-way set-ups, no add-on needed- Scene control: trigger actions with multi-tap (select hubs only)- Smart bulb mode: disable relay and control the light via Z-Wave- Remembers and restores on/off status after power failure- NEW: discreet LED indicator for easy set-up and troubleshooting- Works with LED and incandescent bulbs (dont use with tubes)
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 3 | Lifeline communication with the primary controller with basic reports. |
2 | 5 | Basic set commands for on/off control of other Z-Wave devices in the network. |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Choose if you want to turn the light on or turn the light off when you toggle up the switch. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Toggle up turns the light on, toggle down turns it off (default) |
1 | Toggle up turns the light off, toggle down turns it on |
2 | Toggle any direction to turn the light on/off (change state) |
Enable or disable scene control functionality for quick double tap triggers. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | scene control disabled (default) |
1 | scene control enabled |
Set reporting behavior for disabled physical control. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | switch reports on/off status and change LED indicator state even if physical and Z-Wave control is disabled (default). |
1 | switch doesn't report on/off status or change LED indicator state when physical (and Z-Wave) control is disabled. |
Choose how the switch reports its status back to the hub. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Binary switch report for Z-Wave control, basic set report for toggle (physical) control |
1 | binary switch report for both Z-Wave and toggle control (default) |
Choose how to use the LED indicator. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | LED indicator is on when switch is off, LED indicator is off when switch is on (default) |
1 | LED indicator is on when switch is on, LED indicator is off when switch is off |
2 | LED indicator is always OFF |
3 | LED indicator is always ON |
Use this parameter to enable or disable the auto turn-off timer function (the time after which you want the switch to automatically turn off once it has been turned on). Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | timer disabled |
1 - 65535 | minutes |
Use this parameter to enable or disable the auto turn-on timer function (the time after which you want the switch to automatically turn on once it has been turned off). Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | timer disabled |
1 - 65535 | minutes |
Set the on off status for the switch after power failure. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | forced to OFF (regardless of state prior to power outage |
1 | forced to ON (regardless of state prior to power outage) |
2 | remembers and restores on/off status after power failure (default) |
Hardware Platform | ZGM130 |
Device Type | Binary Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.00 |
Z-Wave Version | 7.13.6 |
Certification ID | ZC12-21050228 |
Z-Wave Product Id | 0x027A.0x7000.0xA003 |
Firmware Updatable | Updatable by Consumer by RF |
Neutral Wire Required | ok |
Color | White |
Electric Load Type | IncandescentLED |
Z-Wave Scene Type | Central Scene |
Security V2 | S2_UNAUTHENTICATED ,S2_AUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |