This is a
FEATURES:- Manual or Z-Wave on/off and brightness control- NEW: 700 series Z-Wave chip for better range and faster control- Simple Direct 3-Way: connect with existing on/off switches in 3-way, 4-way, and 5-way set-ups, no add-on needed- Scene control: trigger actions with multi-tap (select hubs only)- Smart bulb mode: disable relay and control the light via Z-Wave- Night light mode: press down when off to turn lights on to 20%- Multi-color LED indicator for easy pairing and troubleshooting- Works with LED and incandescent bulbs (dont use with tubes)SPECS:- Model Number: ZEN74 VER. 1.0- Z-Wave Signal Frequency: 908.42 MHz- Power: 120 VAC, 60 Hz- Maximum Load: 100 W LED, 300 W incandescent; DONT usewith fans, switches receptacles, or tube lights- Range: Up to 500 feet line of sight- Operating Temperature: 32-104 F (0-40 C)- Installation and Use: Indoor only
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 3 | Lifeline communication with the hub sending basic report. |
2 | 5 | Basic set communication for on/off control devices in Group 2. |
3 | 5 | Multilevel communication for dimming/brightness control devices in Group 3. |
Choose if you want to turn the light on or turn the light off when you toggle up the switch. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Toggle up turns the light on, toggle down turns it off (default) |
1 | Toggle up turns the light off, toggle down turns it on |
2 | Toggle any direction to turn the light on/off (change state). |
Set the minimum brightness level (in %) for your dimmer. You wont be able to dim the light below the set value. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 - 99 | % brightness |
Set the maximum brightness level (in %) for your dimmer. You wont be able to add brightness to the light beyond the set value. Note: if Parameter 12 is set to value 0, Parameter 11 is automatically disabled. Size: 1 Byte, Default Value: 99
Setting | Description |
---|---|
0 | instant on/off |
1 - 99 | % brightness |
Choose what you'd like the dimmer to do when you double-tap the toggle up. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | the light will turn on to full brightness (default) |
1 | the light will turn on to the custom brightness level set in parameter 18 |
2 | the light will turn on to the maximum brightness level set in Parameter 11 |
3 | double tap disabled. |
Enable or disable scene control functionality for quick double tap triggers. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | scene control disabled |
1 - 0 | scene control enabled. |
Enable or disable on/off control from the toggle (aka disable the relay). If disabled, youll only be able to control the connected light via Z-Wave. Scenes and other functionality will still be available from the toggle. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | physical toggle control disabled. |
1 | physical toggle control enabled (default) |
2 | physical toggle and Z-Wave control disabled. |
Set the time it takes to get from 0% to 100% brightness when pressing and holding the toggle (physical dimming). The number entered as value corresponds to the number of seconds. Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
1 - 99 | seconds |
Set the custom brightness level (instead of the last set brightness level) you want the dimmer to come on to when you single tap or double tap the toggle up (see parameters 12 and 25). Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | last brightness level (default) |
1 - 99 | (%) for custom brightness level |
Choose how you'd like the dimmer to report when the toggle is tapped up/down or held and physical / Z-Wave control is enabled or disabled. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | send basic set report for each brightness level to hub when physical / Z-Wave control is disabled for physical dimming when the toggle is manually tapped/ held; report final brightness level only (basic set report) for physical dimming when the toggle is manually tapped/ held and physical / Z-Wave control is enabled; always report final brightness level only (via multilevel reports) for Z-Wave control regardless of the physical / Z-Wave control mode. |
1 | report final brightness level only for physical dimming, regardless of the physical / Z-Wave control mode. |
2 | send multilevel report for each brightness level to hub when physical / Z-Wave control is disabled for physical dimming when the toggle is manually tapped/ held; report final brightness level only (multilevel report) for physical dimming when the toggle is manually tapped/ held and physical / Z-Wave control is enabled; always report final brightness level only (via multilevel reports) for Z-Wave control regardless of the physical / Z-Wave control mode. |
Set reporting behavior for disabled physical control. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | switch reports on/off status and changes LED indicator state even if physical and Z-Wave control is disabled (default). |
1 | switch doesn't report on/off status or change LED indicator state when physical (and Z-Wave) control is disabled. |
Set the brightness level the dimmer will turn on to when off and when toggle is held DOWN for a second. Size: 1 Byte, Default Value: 20
Setting | Description |
---|---|
0 | feature disabled |
1 - 99 | % brightness |
Choose what you'd like the dimmer to do when you tap the toggle up once. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | the light will turn on to the last brightness level (default) |
1 | the light will turn on to the custom brightness level set in parameter 18 |
2 | the light will turn on to the maximum brightness level set in Parameter 11 |
3 | the light will turn on to full brightness. |
Use this parameter to enable or disable the auto turn-off timer function (the time after which you want the switch to automatically turn off once it has been turned on). Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | timer disabled |
1 - 65535 | minutes |
Use this parameter to enable or disable the auto turn-on timer function (the time after which you want the switch to automatically turn on once it has been turned off). Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | timer disabled |
1 - 65535 | minutes |
Set the on off status for the switch after power failure. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | forced to OFF (regardless of state prior to power outage); |
1 | forced to ON (regardless of state prior to power outage) |
2 | remembers and restores on/off status after power failure (default) |
Adjust the ramp rate for your dimmer (fade-in / fade-out effect for on / off operation). Values correspond to the number of seconds it take for the dimmer to reach full brightness or turn off when operated manually. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | instant on/off |
1 - 99 | seconds |
Hardware Platform | ZGM130 |
Device Type | Multilevel Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.00 |
Z-Wave Version | 7.13.6 |
Certification ID | ZC12-21050227 |
Z-Wave Product Id | 0x027A.0x7000.0xA004 |
Neutral Wire Required | ok |
Z-Wave Scene Type | |
Firmware Updatable | |
Electric Load Type | |
Color | |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |