Quickstart

This is a secure Binary Switch for . To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.

This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.

If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.

Product Description

In-Wall Smart Switch design features a housing depth that is up to 20 percent smaller than the previous Z-Wave models. 700 Series Z-Wave Plus On Off Wall Switch with Direct 3-Way Functionality (no add-on switch needed).

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association - one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.

Association Groups:

Group Number Maximum Nodes Description
1 1 Z-Wave Lifeline
2 5 Send BASIC SET Command
3 5 Send BASIC SET Command

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.

IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.

Parameter 1: KeyFunction

Parameter=1Size=1Value=0 Up Button: On Down Button: OffValue=1 Up Button: Off Down Button: On Value=2 Up Button: On/OffDown Button: On/Off
Size: 1 Byte, Default Value: 0

Setting Description
0 Up Button ON,Down Button OFF
1 Up Button OFF,Down Button ON
2 Up Button ON/OFF,Down Button ON/OFF

Parameter 11: Enable or Disable OutPut control

Parameter=11Size=1Value=0 disable local button and External Switch controlenable Z-Wave controlValue=1enable local button and External Switch controlenable Z-Wave controlValue = 2disable local button and External Switch control
Size: 1 Byte, Default Value: 1

Setting Description
0 disable local button and External Switch control
1 enable local button and External Switch control enable Z-Wave control
2 disable local button and External Switch control

Parameter 12: external switch type

Parameter=12, Size=1, Value=0 toggle switch(device changes status when switch changesstatus)(default);Value=1 momentary switch
Size: 1 Byte, Default Value: 0

Setting Description
0 toggle switch (device changes status when switch changes status)
1 momentary switch

Parameter 13: Behavior when Output control disabled

Parameter 13 Size=1Value=0 report on/off status and change LED indicator when upperor lower paddle is pressed and Parameter 11 is set to value 0 or 2 (output control disabled).Value=1 DONt report on/off status or change LED indicator when upperor lower paddle is pressed and Parameter 11 is set to value 0 or 2 (output control disabled).Default = 0
Size: 1 Byte, Default Value: 0

Setting Description
0 report on/off status and change LED indicator when upperor lower paddle is pressed and Parameter 11 is set to value 0 or 2 (output control disabled)
1 DONt report on/off status or change LED indicator when upperor lower paddle is pressed and Parameter 11 is set to value 0 or 2 (output control disabled).

Parameter 14: LED Indicator Color

Parameter=14Size=1Value=0 WhiteValue=1BlueValue=2GreenValue=3Red
Size: 1 Byte, Default Value: 1

Setting Description
0 White
1 Blue
2 Green
3 Red

Parameter 15: LED Indicator Brightness

Parameter=15Size=1Value=0 Bright (100%)Value=1Medium (60%) Value=2Low (30%)
Size: 1 Byte, Default Value: 1

Setting Description
0 Bright (100%)
1 Medium (60%)
2 Low (30%)

Parameter 16: Association reports

Parameter=16Size=1Values:0Z-WavecontrolBinary switch reportManualcontrol:Basic setreport1Z-WavecontrolBinary switch reportManualcontrol: Binary switch report
Size: 1 Byte, Default Value: 1

Setting Description
0 Z-WavecontrolBinary switch report Manualcontrol:Basic setreport
1 Z-WavecontrolBinary switch report Manualcontrol: Binary switch report

Parameter 2: LED Indicator

Parameter=2Size=1Value=0 On when Off and Off when OnValue=1On when On and Off when Off Value=2Always Off Value=3Always On
Size: 1 Byte, Default Value: 0

Setting Description
0 On when Off and Off when On
1 On when On and Off when Off
2 Always OFF
3 Always ON

Parameter 3: Auto Turn-Off Timer

Parameter=3Size=4Value=0timer disabled (default); Values: 165535 (minutes);
Size: 4 Byte, Default Value: 0

Setting Description
0 timer disabled
1 - 65535 Auto Turn-Off Timer

Parameter 5: Auto Turn-On Timer

Parameter=5Size=1Value=0timer disabled (default);Values: 165535 (minutes);
Size: 4 Byte, Default Value: 0

Setting Description
0 timer disabled
1 - 65535 timer disabled

Parameter 8: Restores state after power failure

Parameter=8Size=1Value=0 output offValue=1 output on Value=2out put the state after power
Size: 1 Byte, Default Value: 2

Setting Description
0 output off
1 Output ON
2 out put the state after power

Parameter 9: Enable or Disable Scene

Parameter=9Size=1Value=0 disable Value=1 enable
Size: 1 Byte, Default Value: 0

Setting Description
0 disable
1 enable

Technical Data

Hardware Platform ZGM130
Device Type Binary Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.00
Z-Wave Version 7.13.6
Certification ID ZC12-21040212
Z-Wave Product Id 0x0312.0xEE00.0xEE01
Switch Type Push Button
Firmware Updatable Updatable by Consumer by RF
Color White
Security V2 S2_UNAUTHENTICATED ,S2_AUTHENTICATED
Frequency XXfrequency
Maximum transmission power XXantenna

Supported Command Classes

  • Association Grp Info V3
  • Association V3
  • Basic V2
  • Central Scene V3
  • Configuration V4
  • Device Reset Locally
  • Firmware Update Md V5
  • Indicator V3
  • Manufacturer Specific
  • Multi Channel Association V3
  • Powerlevel
  • Security 2
  • Supervision
  • Switch Binary V2
  • Transport Service V2
  • Version V3
  • Zwaveplus Info V2

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network. Controllers are typically Gateways,Remote Controls or battery operated wall controllers.
  • Slave — is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators and even remote controls.
  • Primary Controller — is the central organizer of the network. It must be a controller. There can be only one primary controller in a Z-Wave network.
  • Inclusion — is the process of adding new Z-Wave devices into a network.
  • Exclusion — is the process of removing Z-Wave devices from the network.
  • Association — is a control relationship between a controlling device and a controlled device.
  • Wakeup Notification — is a special wireless message issued by a Z-Wave device to announces that is able to communicate.
  • Node Information Frame — is a special wireless message issued by a Z-Wave device to announce its capabilities and functions.