This is a
In-Wall Smart Switch design features a housing depth that is up to 20 percent smaller than the previous Z-Wave models. This reduced size coupled with the elimination of heat taps provides a better fit in older style boxes and multi-gang configurations. SimpleWire technology allows line and load to automatically be configured with auto-sensing line-load terminals. All of this is coupled with Z-Wave S2 and SmartStart allows for effortless installation while being safer than ever!
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Z-Wave Lifeline |
2 | 5 | Send BASIC SET COMMAND |
3 | 5 | Send BASIC SET COMMAND |
Parameter=1Size=1Value=0 Up Button: On Down Button: OffValue=1 Up Button: Off Down Button: On Value=2 Up Button: On/OffDown Button: On/Off Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Up Button ON,Down Button OFF |
1 | Up Button OFF,Down Button ON |
2 | Up Button ON/OFF,Down Button ON/OFF |
Parameter=11Size=1Value=0 disable local button and External Switch controlenable Z-Wave controlValue=1enable local button and External Switch controlenable Z-Wave controlValue = 2disable local button and External Switch control Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | disable local button and External Switch control enable Z-Wave conrol |
1 | enable local button and External Switch control enable Z-Wave control |
2 | disable local button and External Switch control |
Parameter=12, Size=1, Value=0 toggle switch(device changes status when switch changesstatus)(default);Value=1 momentary switch Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | toggle switch (device changes status when switch changes status) |
1 | momentary switch |
Parameter 13 Size=1Value=0 report on/off status and change LED indicator when upperor lower paddle is pressed and Parameter 11 is set to value 0 or 2 (output control disabled).Value=1 DONt report on/off status or change LED indicator when upperor lower paddle is pressed and Parameter 11 is set to value 0 or 2 (output control disabled).Default = 0 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | report on/off status and change LED indicator when upperor lower paddle is pressed and Parameter 11 is set to value 0 or 2 (output control disabled) |
1 | DONt report on/off status or change LED indicator when upperor lower paddle is pressed and Parameter 11 is set to value 0 or 2 (output control disabled). |
Parameter=14Size=1Value=0 WhiteValue=1BlueValue=2GreenValue=3Red Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | White |
1 | Blue |
2 | Green |
3 | Red |
Parameter=15Size=1Value=0 Bright (100%)Value=1Medium (60%) Value=2Low (30%) Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Bright (100%) |
1 | Medium (60%) |
2 | Low (30%) |
Parameter=16Size=1Values:0Z-WavecontrolBinary switch reportManualcontrol:Basic setreport1Z-WavecontrolBinary switch reportManualcontrol: Binary switch report Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Z-WavecontrolBinary switch report Manualcontrol:Basic setreport |
1 | Z-WavecontrolBinary switch report Manualcontrol: Binary switch report |
Parameter=2Size=1Value=0 On when Off and Off when OnValue=1On when On and Off when Off Value=2Always Off Value=3Always On Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | On when Off and Off when On |
1 | On when On and Off when Off |
2 | Always OFF |
3 | Always ON |
Parameter=3Size=4Value=0timer disabled (default); Values: 165535 (minutes); Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 65535 | Auto Turn-Off Timer |
Parameter=5Size=1Value=0timer disabled (default);Values: 165535 (minutes); Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 65535 | Auto Turn-On Timer |
Parameter=8Size=1Value=0 output offValue=1 output on Value=2out put the state after power Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | Output OFF |
1 | Output ON |
2 | out put the state after power |
Parameter=9Size=1Value=0 disable Value=1 enable Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | disable |
1 | enable |
Hardware Platform | ZGM130 |
Device Type | Binary Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.00 |
Z-Wave Version | 7.13.6 |
Certification ID | ZC12-21040211 |
Z-Wave Product Id | 0x0312.0xEE00.0xEE03 |
Color | White |
Switch Type | Toggle |
Firmware Updatable | Updatable by Consumer by RF |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |