Quickstart

This is a secure Binary Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

FEATURES:- Powerful dry contact NO/NC relays to control loads up to 20 A for NO- Perfect for DC motors, pumps, commercial gates, or HVAC equipment- Control up to 2 connected loads independently or together- Z-Wave or optional wall switch control (toggle or momentary type)- Monitor inputs independently from output control- Built-in timers for each relay to simplify automation- Built-in Z-Wave Plus signal repeater to extend network range- Powered by 12-24 V DC/AC or USB C port for easy set-up- Wall mounting and minimal design for clean installation- NEW 700 Z-Wave chip, S2 security, and SmartStartSPECS:- Model Number: ZEN17- Z-Wave Signal Frequency: 908.42 MHz- Power: 12-24 V DC/AC or USB C (DONT use laptop / tablet chargers)- Maximum Load: NO relays: 20 A, NC relays: 10 A- Inputs: dry contact or 12-24 V AC/DC (use 1 input type at a time!)- Range: Up to 200 feet line of sight- Operating Temperature: 32-104 F (0-40 C)- Installation and Use: Indoor only

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Lifeline communication to the hub
2 5 Basic set for devices associated with relay 1
3 5 Basic set for devices associated with relay 2

Configuration Parameters

Parameter 1: On Off Status After Power Failure

Set the on off status for the relays after power failure.
Size: 1 Byte, Default Value: 1

Setting Description
0 ALL relays forced to OFF (regardless of state prior to power outage)
1 ALL relays remember and restore on/off status after power failure (default)
2 ALL relays forced to ON (regardless of state prior to power outage)
3 Relay 1 remembers and restores on/off status after power failure, Relay 2 forced to ON
4 Relay 2 remembers and restores on/off status after power failure, Relay 1 forced to ON.

Parameter 10: Input Trigger for Relay 1

Choose if youd like the connected input (switch) on S1 C / VC C to trigger the load connected to R1 or if you want to use the input reports for monitoring only and separate theoutput from the input.
Size: 1 Byte, Default Value: 1

Setting Description
0 input trigger disabled
1 input trigger enabled (default)

Parameter 11: Input Trigger for Relay 2

Choose if youd like the connected input (switch) on S2 C / VC C to trigger the load connected to R2 or if you want to use the input reports for monitoring only and separate the output from the input.
Size: 1 Byte, Default Value: 1

Setting Description
0 input trigger disabled
1 input trigger enabled (default)

Parameter 15: Auto Turn-Off Timer Unit for Relay 1

Choose between seconds, minutes, and hours as the unit for the auto turnoff timer for Relay 1.
Size: 1 Byte, Default Value: 0

Setting Description
0 minutes
1 seconds
2 hours

Parameter 16: Auto Turn-On Timer Unit for Relay 1

Choose between seconds, minutes, and hours as the unit for the auto turn on timer for Relay 1.
Size: 1 Byte, Default Value: 0

Setting Description
0 minutes
1 seconds
2 hours

Parameter 17: Auto Turn-Off Timer Unit for Relay 2

Choose between seconds, minutes, and hours as the unit for the auto turn off timer for Relay 2.
Size: 1 Byte, Default Value: 0

Setting Description
0 minutes
1 seconds
2 hours

Parameter 18: Auto Turn-On Timer Unit for Relay 2

Choose between seconds, minutes, and hours as the unit for the auto turn on timer for Relay 2.
Size: 1 Byte, Default Value: 0

Setting Description
0 minutes
1 seconds
2 hours

Parameter 2: Input Type for Relay 1 (S1)

Choose the wall switch or input type you want to connect to the S1 C terminals.Press and hold the Z-Wave button for 5 seconds to change to garage mode manually.IMPORTANT: If you set this parameter to value 4-10, youll need to exclude and re-include the device (without changing any settings) so that a child device is created for the input of your choice!
Size: 1 Byte, Default Value: 2

Setting Description
0 momentary for lights only
1 toggle switch (light on when the switch is toggled up, light off when the switch is toggled down);
2 toggle switch (state changes whenever the switch is toggled)
3 garage door (momentary mode for Z-Wave control)
4 leak alarm (water sensor)
5 heat alarm
6 motion alert
7 open/close alert (door sensor)
8 CO alarm
9 CO2 alarm
10 on/off report (dry contact switch/sensor)

Parameter 24: DC Motor Mode

Sync R1 and R2 together to prevent them from being activated at the same time.
Size: 1 Byte, Default Value: 0

Setting Description
0 DC motor mode disabled (relays will activate whenever they're triggered)
1 DC motor mode enabled (relay will check the status of the other relay aer being triggered and will shut the other relay off before activating so that only one of the relays is on at the same time)

Parameter 3: Input Type for Relay 2 (S2)

Choose the wall switch or input type you want to connect to the S2 C terminals.Click twice, holding the Z-Wave button for 5 seconds the second time to change to garage mode manually. IMPORTANT: If you set this parameter to value 4-10, youll need to exclude and re-include the device (without changing any settings) so that a child device is created for the input of your choice!
Size: 1 Byte, Default Value: 2

Setting Description
0 momentary for lights only
1 toggle switch (light on when the switch is toggled up, light off when the switch is toggled down)
2 toggle switch (state changes whenever the switch is toggled)
3 garage door (momentary mode for Z-Wave control)
4 leak alarm (water sensor)
5 heat alarm
6 motion alert
7 open/close alert (door sensor)
8 CO alarm
9 CO2 alarm
10 on/off report (dry contact switch/sensor)

Parameter 5: LED Indicator Control

Choose if you want the LED indicator to turn on when any of the relays are on or if all of them are off, or if you want it to remain on or off at all times.
Size: 1 Byte, Default Value: 0

Setting Description
0 LED indicator is on when ALL of the relays are off, LED indicator is off when any of the relays is on (default);
1 LED indicator is on when any of the relays is on, LED indicator is off when ALL of the relays are off;
2 LED indicator is always OFF;
3 LED indicator is always ON

Parameter 6: Auto Turn-Off Timer for Relay 1

Use this parameter to set the time after which you want the device connected to Relay 1 to automatically turn off once it has been turned on. The number entered as valuecorresponds to the number of minutes, seconds, or hours (set the unit in Par. 15).
Size: 4 Byte, Default Value: 0

Setting Description
0 disabled
1 - 65535 minutes/seconds/hours

Parameter 7: Auto Turn-On Timer for Relay 1

Use this parameter to set the time after which you want the device connected to Relay 1 to automatically turn on once it has been turned off. The number entered as valuecorresponds to the number of minutes, seconds, or hours (set the unit in Par. 16).
Size: 4 Byte, Default Value: 0

Setting Description
0 disabled
1 - 65535 minutes/seconds/hours

Parameter 8: Auto Turn-Off Timer for Relay 2

Use this parameter to set the time after which you want the device connected to Relay 2 to automatically turn off once it has been turned on. The number entered as value corresponds to the number of minutes, seconds, or hours (set the unit in Par. 17).
Size: 4 Byte, Default Value: 0

Setting Description
0 disabled
1 - 65535 minutes/seconds/hours

Parameter 9: Auto Turn-On Timer for Relay 2

Use this parameter to set the time after which you want the device connected to Relay 2 to automatically turn on once it has been turned off. The number entered as value corresponds to the number of minutes, seconds, or hours (set the unit in Par. 18).
Size: 4 Byte, Default Value: 0

Setting Description
0 disabled
1 - 65535 minutes/seconds/hours

Technical Data

Hardware Platform ZGM130
Device Type Binary Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.00
Z-Wave Version 7.13.6
Certification ID ZC12-21030204
Z-Wave Product Id 0x027A.0xBB00.0xBB0A
Switch Type Dry Contact
Electric Load Type FluorescentIncandescentInductive (e.g. Motor)LEDMLV (Magnetic)
Loads Controlled 2
Firmware Updatable Updatable by Consumer by RF
Color Gray
Frequency XXfrequency
Maximum transmission power XXantenna
Binary Switch