This is a
FEATURES:- Powerful dry contact NO/NC relays to control loads up to 20 A for NO- Perfect for DC motors, pumps, commercial gates, or HVAC equipment- Control up to 2 connected loads independently or together- Z-Wave or optional wall switch control (toggle or momentary type)- Monitor inputs independently from output control- Built-in timers for each relay to simplify automation- Built-in Z-Wave Plus signal repeater to extend network range- Powered by 12-24 V DC/AC or USB C port for easy set-up- Wall mounting and minimal design for clean installation- NEW 700 Z-Wave chip, S2 security, and SmartStartSPECS:- Model Number: ZEN17- Z-Wave Signal Frequency: 908.42 MHz- Power: 12-24 V DC/AC or USB C (DONT use laptop / tablet chargers)- Maximum Load: NO relays: 20 A, NC relays: 10 A- Inputs: dry contact or 12-24 V AC/DC (use 1 input type at a time!)- Range: Up to 200 feet line of sight- Operating Temperature: 32-104 F (0-40 C)- Installation and Use: Indoor only
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Lifeline communication to the hub |
2 | 5 | Basic set for devices associated with relay 1 |
3 | 5 | Basic set for devices associated with relay 2 |
Set the on off status for the relays after power failure. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | ALL relays forced to OFF (regardless of state prior to power outage) |
1 | ALL relays remember and restore on/off status after power failure (default) |
2 | ALL relays forced to ON (regardless of state prior to power outage) |
3 | Relay 1 remembers and restores on/off status after power failure, Relay 2 forced to ON |
4 | Relay 2 remembers and restores on/off status after power failure, Relay 1 forced to ON. |
Choose if youd like the connected input (switch) on S1 C / VC C to trigger the load connected to R1 or if you want to use the input reports for monitoring only and separate theoutput from the input. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | input trigger disabled |
1 | input trigger enabled (default) |
Choose if youd like the connected input (switch) on S2 C / VC C to trigger the load connected to R2 or if you want to use the input reports for monitoring only and separate the output from the input. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | input trigger disabled |
1 | input trigger enabled (default) |
Choose between seconds, minutes, and hours as the unit for the auto turnoff timer for Relay 1. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | minutes |
1 | seconds |
2 | hours |
Choose between seconds, minutes, and hours as the unit for the auto turn on timer for Relay 1. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | minutes |
1 | seconds |
2 | hours |
Choose between seconds, minutes, and hours as the unit for the auto turn off timer for Relay 2. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | minutes |
1 | seconds |
2 | hours |
Choose between seconds, minutes, and hours as the unit for the auto turn on timer for Relay 2. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | minutes |
1 | seconds |
2 | hours |
Choose the wall switch or input type you want to connect to the S1 C terminals.Press and hold the Z-Wave button for 5 seconds to change to garage mode manually.IMPORTANT: If you set this parameter to value 4-10, youll need to exclude and re-include the device (without changing any settings) so that a child device is created for the input of your choice! Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | momentary for lights only |
1 | toggle switch (light on when the switch is toggled up, light off when the switch is toggled down); |
2 | toggle switch (state changes whenever the switch is toggled) |
3 | garage door (momentary mode for Z-Wave control) |
4 | leak alarm (water sensor) |
5 | heat alarm |
6 | motion alert |
7 | open/close alert (door sensor) |
8 | CO alarm |
9 | CO2 alarm |
10 | on/off report (dry contact switch/sensor) |
Sync R1 and R2 together to prevent them from being activated at the same time. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | DC motor mode disabled (relays will activate whenever they're triggered) |
1 | DC motor mode enabled (relay will check the status of the other relay aer being triggered and will shut the other relay off before activating so that only one of the relays is on at the same time) |
Choose the wall switch or input type you want to connect to the S2 C terminals.Click twice, holding the Z-Wave button for 5 seconds the second time to change to garage mode manually. IMPORTANT: If you set this parameter to value 4-10, youll need to exclude and re-include the device (without changing any settings) so that a child device is created for the input of your choice! Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | momentary for lights only |
1 | toggle switch (light on when the switch is toggled up, light off when the switch is toggled down) |
2 | toggle switch (state changes whenever the switch is toggled) |
3 | garage door (momentary mode for Z-Wave control) |
4 | leak alarm (water sensor) |
5 | heat alarm |
6 | motion alert |
7 | open/close alert (door sensor) |
8 | CO alarm |
9 | CO2 alarm |
10 | on/off report (dry contact switch/sensor) |
Choose if you want the LED indicator to turn on when any of the relays are on or if all of them are off, or if you want it to remain on or off at all times. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | LED indicator is on when ALL of the relays are off, LED indicator is off when any of the relays is on (default); |
1 | LED indicator is on when any of the relays is on, LED indicator is off when ALL of the relays are off; |
2 | LED indicator is always OFF; |
3 | LED indicator is always ON |
Use this parameter to set the time after which you want the device connected to Relay 1 to automatically turn off once it has been turned on. The number entered as valuecorresponds to the number of minutes, seconds, or hours (set the unit in Par. 15). Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | disabled |
1 - 65535 | minutes/seconds/hours |
Use this parameter to set the time after which you want the device connected to Relay 1 to automatically turn on once it has been turned off. The number entered as valuecorresponds to the number of minutes, seconds, or hours (set the unit in Par. 16). Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | disabled |
1 - 65535 | minutes/seconds/hours |
Use this parameter to set the time after which you want the device connected to Relay 2 to automatically turn off once it has been turned on. The number entered as value corresponds to the number of minutes, seconds, or hours (set the unit in Par. 17). Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | disabled |
1 - 65535 | minutes/seconds/hours |
Use this parameter to set the time after which you want the device connected to Relay 2 to automatically turn on once it has been turned off. The number entered as value corresponds to the number of minutes, seconds, or hours (set the unit in Par. 18). Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | disabled |
1 - 65535 | minutes/seconds/hours |
Hardware Platform | ZGM130 |
Device Type | Binary Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.00 |
Z-Wave Version | 7.13.6 |
Certification ID | ZC12-21030204 |
Z-Wave Product Id | 0x027A.0xBB00.0xBB0A |
Switch Type | Dry Contact |
Electric Load Type | FluorescentIncandescentInductive (e.g. Motor)LEDMLV (Magnetic) |
Loads Controlled | 2 |
Firmware Updatable | Updatable by Consumer by RF |
Color | Gray |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |