This is a
Never worry about carrying around or losing your keys again. Unlock and lock your home with ease from the backlit touchscreen keypad. Create unique entry codes for friends and family and remove codes whenever you need to. This lock features Z-Wave and seamlessly integrates into 50+ home automation and security systems. When added to most Z-Wave automation systems, lock and unlock your door, create pin codes, view access history and receive notifications from anywhere. The lock is tamper resistant, easy to install and even easier to use!
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 3 | the description is lifeline. |
Set Volume Level to high (1), low (2), or silent (3). Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
1 - 3 | Volume |
Set One Touch Locking feature to enable or disable. Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 - 255 | One Touch Locking |
Set Privacy Button feature to enable or disable. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 255 | Privacy Button |
Set Lock Status LED feature to enable or disable. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 255 | Lock Status LED |
Set Auto Relock feature to enable or disable. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 255 | Auto Relock |
Adjust the time your lock will auto relock. Size: 1 Byte, Default Value: 30
Setting | Description |
---|---|
0 - 127 | Relock Time |
Adjust the limit for wrong code entries allowed by your lock. Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 - 5 | Wrong Code Entry Limit |
Set the language to English (1), Spanish (2), or French (3). Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 - 3 | Language |
Adjust the time your lock is shutdown after reaching its wrong code entry limit. Size: 1 Byte, Default Value: 60
Setting | Description |
---|---|
0 - 127 | Shut Down Time |
Set the Operating Mode to normal mode(0), vacation mode(1) or privacy mode(2). Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 2 | Operating Mode |
Lock will execute Reset To Factory when parameter is set. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | Reset to Factory Resets |
Hardware Platform | ZGM130 |
Device Type | Lock |
Network Operation | Listening Sleeping Slave |
Firmware Version | HW: 2 FW: 2.13:43.19 |
Z-Wave Version | 7.12.2 |
Certification ID | ZC12-21020185 |
Z-Wave Product Id | 0x0129.0x8004.0x46C1 |
Color | Antique Brass |
Communications Connections | None |
Firmware Updatable | Updatable by Consumer by RF |
Controller Supports Multiple Z-Wave Interfaces | ok |
Communications Protocol | Z-Wave Serial API |
Door Lock Type | Deadbolt |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |