This is a
This product is a multi-channel Z-Wave breaker with built-in S2 security.Built-in high-power relay, multi-type external switch selection.Very convenient.
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Z-Wave Lifeline |
2 | 5 | Send on/off control |
3 | 5 | Send on/off control |
Restore state after power failure: always off, always on or follow the status before power failure Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | All relays automatically turn OFF once power is restored |
1 | All relays remember the status prior to power outage and turns back to it |
2 | All relays turned on after power failure |
3 | R1 recovered, R2 ON |
4 | R2 recovered, R1ON |
Connect input and output or separate the output from the input for switch 1 Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | trigger disable (only notification to hub according to set par 2) |
1 | trigger unable (default); trigger the relay and hub notification |
Connect input and output or separate the output from the input for switch 2 Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | trigger disable (only notification to hub according to set par 2) |
1 | trigger unable (default); trigger the relay and hub notification |
User can set it to disable the output for switch one Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | manual control disabled (no reports to the hub) |
1 | manual control enabled |
2 | manual control disabled (sends on/off reports to the hub) |
User can set it to disable the output for switch two Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | manual control disabled (no reports to the hub) |
1 | manual control enabled |
2 | manual control disabled (sends on/off reports to the hub) |
Setting auto off timer unit(minutes, seconds or hours) for relay one Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | minutes |
1 | seconds |
2 | hours |
Setting auto on timer unit(minutes, seconds or hours) for relay one Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | minutes |
1 | seconds |
2 | hours |
Setting auto off timer unit(minutes, seconds or hours) for relay two Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | minutes |
1 | seconds |
2 | hours |
Setting auto on timer unit(minutes, seconds or hours) for relay two Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | minutes |
1 | seconds |
2 | hours |
Select switch one's type: switch or sensor Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | momentary switch |
1 | toggle switch (contact closed -ON, contact opened - OFF) |
2 | toggle switch (device changes status when switch changes status) |
3 | garage door mode(toggle switch type for external switch (like in value 1) + built-in 2 second auto-off timer for Z-Wave control (so if user turns the relay on from the Z-Wave hub, it will automatically turn off after 2 seconds) |
4 | water alarm |
5 | heat alarm |
6 | Smoke alarm |
7 | Door alarm |
8 | CO alarm |
9 | CO2 alarm |
DC motor mode: sync R1 and R2 together to prevent them from being activated at the same time Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Normal |
1 | Union (only switch type1 < 4 && switch type2 < 4) IF both switches OFF - only one of them may be turned ON. - turning sw1 ON : delayed 0.5 s, sw2 and R2 turned off first (immediately) - turning sw2 ON - delayed 0.5s , sw1and R1 turned off first ( immediately ) The situation for DC motor control(SW1 controlright, SW2 control-left. -main switch can turn ON and OFF only sw1 |
Select switch two's type: switch or sensor Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | momentary switch |
1 | toggle switch (contact closed -ON, contact opened - OFF) |
2 | toggle switch (device changes status when switch changes status) |
3 | garage door mode(toggle switch type for external switch (like in value 1) + built-in 2 second auto-off timer for Z-Wave control (so if user turns the relay on from the Z-Wave hub, it will automatically turn off after 2 seconds) |
4 | water alarm |
5 | heat alarm |
6 | Smoke alarm |
7 | Door alarm |
8 | CO alarm |
9 | CO2 alarm |
Indicator inverse, follow, always on or always off Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | LED on when relay off, LED off when relay on |
1 | LED on when relay on, LED off when relay off |
2 | LED Always OFF |
3 | LED Always ON |
Setting auto off timer value for relay one Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 65535 | EP1 Auto Turn-off Timer |
Setting auto on timer value for relay one Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 65535 | EP1 Auto Turn-on Timer |
Setting auto off timer value for relay two Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 65535 | EP2 Auto Turn-off Timer |
Setting auto on timer value for relay two Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 65535 | EP2 Auto Turn-on Timer |
Hardware Platform | ZGM130 |
Device Type | Binary Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.00 |
Z-Wave Version | 7.13.6 |
Certification ID | ZC12-21020174 |
Z-Wave Product Id | 0x0312.0xBB00.0xBB0A |
Firmware Updatable | Updatable by Consumer by RF |
Switch Type | Push Button |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |