Quickstart

This is a secure Binary Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

This product is a multi-channel Z-Wave breaker with built-in S2 security.Built-in high-power relay, multi-type external switch selection.Very convenient.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Z-Wave Lifeline
2 5 Send on/off control
3 5 Send on/off control

Configuration Parameters

Parameter 1: Restore state after power failure

Restore state after power failure: always off, always on or follow the status before power failure
Size: 1 Byte, Default Value: 1

Setting Description
0 All relays automatically turn OFF once power is restored
1 All relays remember the status prior to power outage and turns back to it
2 All relays turned on after power failure
3 R1 recovered, R2 ON
4 R2 recovered, R1ON

Parameter 10: Input 1 trigerring

Connect input and output or separate the output from the input for switch 1
Size: 1 Byte, Default Value: 1

Setting Description
0 trigger disable (only notification to hub according to set par 2)
1 trigger unable (default); trigger the relay and hub notification

Parameter 11: Input 2 trigerring

Connect input and output or separate the output from the input for switch 2
Size: 1 Byte, Default Value: 1

Setting Description
0 trigger disable (only notification to hub according to set par 2)
1 trigger unable (default); trigger the relay and hub notification

Parameter 12: EP1 Manual Control

User can set it to disable the output for switch one
Size: 1 Byte, Default Value: 1

Setting Description
0 manual control disabled (no reports to the hub)
1 manual control enabled
2 manual control disabled (sends on/off reports to the hub)

Parameter 13: EP2 Manual Control

User can set it to disable the output for switch two
Size: 1 Byte, Default Value: 1

Setting Description
0 manual control disabled (no reports to the hub)
1 manual control enabled
2 manual control disabled (sends on/off reports to the hub)

Parameter 15: EP1 Auto Turn-Off Timer Unit

Setting auto off timer unit(minutes, seconds or hours) for relay one
Size: 1 Byte, Default Value: 0

Setting Description
0 minutes
1 seconds
2 hours

Parameter 16: EP1 Auto Turn-ON Timer Unit

Setting auto on timer unit(minutes, seconds or hours) for relay one
Size: 1 Byte, Default Value: 0

Setting Description
0 minutes
1 seconds
2 hours

Parameter 17: EP2 Auto Turn-Off Timer Unit

Setting auto off timer unit(minutes, seconds or hours) for relay two
Size: 1 Byte, Default Value: 0

Setting Description
0 minutes
1 seconds
2 hours

Parameter 18: EP2 Auto Turn-ON Timer Unit

Setting auto on timer unit(minutes, seconds or hours) for relay two
Size: 1 Byte, Default Value: 0

Setting Description
0 minutes
1 seconds
2 hours

Parameter 2: Select switch one's type

Select switch one's type: switch or sensor
Size: 1 Byte, Default Value: 2

Setting Description
0 momentary switch
1 toggle switch (contact closed -ON, contact opened - OFF)
2 toggle switch (device changes status when switch changes status)
3 garage door mode(toggle switch type for external switch (like in value 1) + built-in 2 second auto-off timer for Z-Wave control (so if user turns the relay on from the Z-Wave hub, it will automatically turn off after 2 seconds)
4 water alarm
5 heat alarm
6 Smoke alarm
7 Door alarm
8 CO alarm
9 CO2 alarm

Parameter 24: Sw1,Sw2 setting

DC motor mode: sync R1 and R2 together to prevent them from being activated at the same time
Size: 1 Byte, Default Value: 0

Setting Description
0 Normal
1 Union (only switch type1 < 4 && switch type2 < 4) IF both switches OFF - only one of them may be turned ON. - turning sw1 ON : delayed 0.5 s, sw2 and R2 turned off first (immediately) - turning sw2 ON - delayed 0.5s , sw1and R1 turned off first ( immediately ) The situation for DC motor control(SW1 controlright, SW2 control-left. -main switch can turn ON and OFF only sw1

Parameter 3: Select switch two's type

Select switch two's type: switch or sensor
Size: 1 Byte, Default Value: 2

Setting Description
0 momentary switch
1 toggle switch (contact closed -ON, contact opened - OFF)
2 toggle switch (device changes status when switch changes status)
3 garage door mode(toggle switch type for external switch (like in value 1) + built-in 2 second auto-off timer for Z-Wave control (so if user turns the relay on from the Z-Wave hub, it will automatically turn off after 2 seconds)
4 water alarm
5 heat alarm
6 Smoke alarm
7 Door alarm
8 CO alarm
9 CO2 alarm

Parameter 5: LED indicator

Indicator inverse, follow, always on or always off
Size: 1 Byte, Default Value: 0

Setting Description
0 LED on when relay off, LED off when relay on
1 LED on when relay on, LED off when relay off
2 LED Always OFF
3 LED Always ON

Parameter 6: EP1 Auto Turn-off Timer

Setting auto off timer value for relay one
Size: 4 Byte, Default Value: 0

Setting Description
0 - 65535 EP1 Auto Turn-off Timer

Parameter 7: EP1 Auto Turn-on Timer

Setting auto on timer value for relay one
Size: 4 Byte, Default Value: 0

Setting Description
0 - 65535 EP1 Auto Turn-on Timer

Parameter 8: EP2 Auto Turn-off Timer

Setting auto off timer value for relay two
Size: 4 Byte, Default Value: 0

Setting Description
0 - 65535 EP2 Auto Turn-off Timer

Parameter 9: EP2 Auto Turn-on Timer

Setting auto on timer value for relay two
Size: 4 Byte, Default Value: 0

Setting Description
0 - 65535 EP2 Auto Turn-on Timer

Technical Data

Hardware Platform ZGM130
Device Type Binary Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.00
Z-Wave Version 7.13.6
Certification ID ZC12-21020174
Z-Wave Product Id 0x0312.0xBB00.0xBB0A
Firmware Updatable Updatable by Consumer by RF
Switch Type Push Button
Frequency XXfrequency
Maximum transmission power XXantenna
Binary Switch