This is a
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Air quality sensor SZ-AIR-HTQ01 is a multifunctional sensor thatmeasures the following parameters: temperature, relative humidity, CO2 and tVOC. The sensor supports the Z-Wave Plus v2 protocol, which means support for encryption and firmware updates Over The Air (OTA update). The device can operate in any Z-Wave network with certified devices from any other manufacturer. The device uses Z-Wave series 700 chip.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | General messages: reset locally, indicator, notification and sensor multilevel. |
2 | 5 | Temperature reports |
3 | 5 | Humidity reports |
4 | 5 | Reports on the level of CO2 |
5 | 5 | Total volatile Organic Compaund level |
6 | 5 | The group for heat alarms |
7 | 5 | The group for CO2 level changing alarms |
8 | 5 | Home health alarms |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Set minimal temperature Size: 2 Byte, Default Value: 18
Setting | Description |
---|---|
1 - 18 | The minimum temperature in degrees Celcius |
Set times report Size: 2 Byte, Default Value: 300
Setting | Description |
---|---|
60 - 10800 | The interval between readings sending |
Setdelta temperature report Size: 2 Byte, Default Value: 1
Setting | Description |
---|---|
1 - 10 | The change in temperature values at which the report sending occurs |
Set delta humidity report Size: 2 Byte, Default Value: 5
Setting | Description |
---|---|
1 - 10 | Humidity value change at which the sending occurs |
Set delta CO2 report Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
10 - 1000 | CO2 value change at which the sending occurs |
Set delta tVOC report Size: 2 Byte, Default Value: 100
Setting | Description |
---|---|
10 - 1000 | tVOC value change at which the sending occurs |
Set maximum temperature Size: 2 Byte, Default Value: 27
Setting | Description |
---|---|
27 - 80 | The maximum temperature in degrees Celcius |
Set maximum level CO2 Size: 2 Byte, Default Value: 750
Setting | Description |
---|---|
400 - 3000 | The maximum level of CO2 in ppm |
Set minimum level tVOC Size: 2 Byte, Default Value: 65
Setting | Description |
---|---|
0 - 99 | The minimum level of total volitile organic compound in ppb |
Set middle level tVOC Size: 2 Byte, Default Value: 550
Setting | Description |
---|---|
100 - 1000 | The average level of total volitile organic compound in ppb |
Set maximum level tVOC Size: 2 Byte, Default Value: 5000
Setting | Description |
---|---|
1001 - 5000 | The maximum level of total volitile organic compound in ppb |
Set indicate control Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Enable (1) or disable (0) air quality indication |
Hardware Platform | ZGM130 |
Device Type | Notification Sensor |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.01 |
Z-Wave Version | 7.13.6 |
Certification ID | ZC12-21010171 |
Z-Wave Product Id | 0x039B.0x0003.0x000A |
Security V2 | S2_UNAUTHENTICATED ,S2_AUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |