This is a
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
This light switch features:- Manual or remote on/off control and dimming from your mobile device or computer (when included to a Z-Wave gateway controller)- Z-Wave Plus with improved 500 chip for faster and safer wireless communication- Works with most high-quality DIMMABLE LED, CFL, and incandescent bulbs- Based on universal command classes - supported by most Z-Wave controllers- May be associated and grouped with other Z-Wave devices for advanced home automation- LED indicator to help locate the switch in dark space- Simple elegant design with screwless snap-on wall plate included- Built-in Z-Wave signal repeater for a stronger and more reliable networkZ-Wave Signal Frequency: 908.42 MHzPower: 120 VAC, 60 HzMaximum Loads: 600W Single-gang, 500W Double-gang, 400W Triple-gang Incandescent, 150W CFL or LEDMinimum Load: 20W for LED and CFL bulbsRange: Up to 100 feet line of sightOperating Temperature: 32-104 F (0-40 C)Installation and Use: Indoor only
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Z-Wave Linelife |
2 | 5 | send on/off control |
3 | 5 | send on/off control |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Parameter=1Size=1Value=0 Up Button: On Down Button: OffValue=1 Up Button: Off Down Button: On Value=2 Up Button: On/OffDown Button: On/OffDefault = 0 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Up Button ON,Down Button OFF |
1 | Up Button OFF,Down Button ON |
2 | Up Button: On/Off Down Button: On/Off |
Multilevel minimumvalue can be setLocal Button> this should apply to both for local or Z-Wave operationParameter=10Size=1Value=0disableValue=1..Value=99 Default = 1 Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 99 | Multilevel minimumvalue |
Multilevel maximumvalue can be setLocal Button> this should apply to both for local or Z-Wave operationParameter=11Size=1Value=0disableValue=1..Value=100- NOT ACCEPTED BY HUBDefault = 99 Size: 1 Byte, Default Value: 99
Setting | Description |
---|---|
0 - 100 | Multilevel maximumvalue can be set |
Double Tap Behavior: when switch is off and quickly press UPPER paddle 2 times, switch turns on to x brightnessLocal Button Parameter=12Size=1Value = 0enable double tap to full brightness (99)Value = 1 custom value set in parameter 18 Value = 2 enable double tap to maximum brightness (turn on to the value relate with parameter 11) Value = 3 disable double tap to full brightnessDefault = 0 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | enable double tap to full brightness (99) |
1 | custom value set in parameter 18 |
2 | enable double tap to maximum brightness (turn on to the value relate with parameter 11) |
3 | disable double tap to full brightness |
Enable or Disable local / Z-Wave control Parameter=15Size=1Value=0 disable (when paddle pressed switch will not turn light on or off BUT it will still control the light via z-wave and it will change LED indicator status and on/off/multilevel status when paddle is pressed)Value=1 enable (normal operation like now)Value = 2 disable local and Z-Wave control (LED and on/off status will still change if paddle pressed) >> make sure that status is still reported and LED indicator changes when Z-Wave control is disabledDefault = 1 Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | disable (when paddle pressed switch will not turn light on or off BUT it will still control the light via z-wave and it will change LED indicator status and on/off/multilevel status when paddle is pressed) |
1 | enable (normal operation like now) |
2 | disable local and Z-Wave control (LED and on/off status will still change if paddle pressed) >> make sure that status is still reported and LED indicator changes when Z-Wave control is disabled |
dimmer speed (only for local press & hold): amount of seconds it takes to go from 0 to 100% brightness when pressing and holding the paddleParameter=16Size=1,Value=1from 0x63 to 0x00 or from 0x00 to 0x63 need 1sValue=2 from 0x63 to 0x00 or from 0x00 to 0x63 need 2s ..Value=99 from 0x63 to 0x00 or from 0x00 to 0x63 need 99sDefault = 5 Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
1 - 99 | dimmer speed |
Custom brightness level - in this parameter define default brightness level the switch will turn on to from main switch or regular switch in 3-way when pressed upper paddle once.Parameter: 18Size: 1 byte decValues 0-990 - last brightness level1-99 custom brightness leveldefault = 0 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 99 | Custom brightness level |
3-way switch typeParameter=19,Size=1,Value=0 toggle switch(device changes status when switch changes status,it can only turn on or turn off lamp,it cant dimmer)(default);Value = 1toggle switch(press 1x change device status;quickly press 2x the result dependonPar11/Par12; quickly Press 3x it trigger dimmer in loop(dimmer up/dimmer down )Value=2 momentary switch (press 1x change device status;quickly press 2x the result dependonPar11/Par12;holdtrigger dimmer in loop(dimmer up/dimmer down )Value=3 momentary switch (press 1x change device status;quickly press 2x the result dependonPar11/Par12;holdtrigger dimmer in loop(dimmer up/dimmer downBUT after double click to full brightness, hold will dim DOWN always instead of trying to increase brightness) >> This value is missing, please add to settingNotice: when the value=1,or value=2,the switch cant respond immediately,because it need to recognize multiplepress. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | toggle switch(device changes status when switch changesstatus,it can only turn on or turn off lamp,it cant dimmer) |
1 | toggle switch(press 1x change device status;quickly press 2x the result dependonPar11/Par12; quickly Press 3x it trigger dimmer in loop(dimmer up/dimmer down ) |
2 | momentary switch (press 1x change device status;quickly press 2x the result dependonPar11/Par12;holdtrigger dimmer in loop(dimmer up/dimmer down ) |
3 | momentary switch (press 1x change device status;quickly press 2x the result dependonPar11/Par12;holdtrigger dimmer in loop(dimmer up/dimmer downBUT after double click to full brightness, hold will dim DOWN always instead of trying to increase brightness) >> This value is missing, please add to setting |
Parameter=2Size=1Value=0 On when Off and Off when OnValue=1On when On and Off when OffValue=2Always OffValue=3Always OnDefault =0 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | On when Off and Off when On |
1 | On when On and Off when Off |
2 | Always Off |
3 | Always ON |
Association reportsParameter=20,Size=1Values:0Z-WavecontrolMultilevelreport (withouteachlevel,justfinallevel)Manualcontrol (shortpress):Basicreport(withouteachlevel,justfinallevel)Manualcontrol(longpress & relayenable):Basicreport(withouteachlevel,justfinallevel)Manualcontrol(longpress &relaydisable):Multilevelreport (eachlevelwillbereported) 1Z-WavecontrolMultilevelreport (withouteachlevel,justfinallevel)Manualcontrol (shortpress):Basicreport (withouteachlevel,justfinallevel)Manualcontrol(longpress & relayenable OR disable):Basicreport (withouteachlevel,justfinallevel)2Z-WavecontrolMultilevelreport (withouteachlevel, justfinallevel)Manualcontrol (shortpress): Multilevel report (withouteachlevel, justfinallevel)Manualcontrol (longpress & relayenable):Multilevelreport (withouteachlevel, justfinallevel)Manualcontrol (longpress &relaydisable):Multilevelreport (eachlevelwillbereported)default = 2 Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | Z-WavecontrolMultilevelreport (withouteachlevel,justfinallevel) Manualcontrol (shortpress):Basicreport(withouteachlevel,justfinallevel) Manualcontrol(longpress & relayenable):Basicreport(withouteachlevel,justfinallevel) Manualcontrol(longpress &relaydisable):Multilevelreport (eachlevelwillbereported) |
1 | Z-WavecontrolMultilevelreport (withouteachlevel,justfinallevel) Manualcontrol (shortpress):Basicreport (withouteachlevel,justfinallevel) Manualcontrol(longpress & relayenable OR disable):Basicreport (withouteachlevel,justfinallevel) |
2 | Z-WavecontrolMultilevelreport (withouteachlevel, justfinallevel) Manualcontrol (shortpress): Multilevel report (withouteachlevel, justfinallevel) Manualcontrol (longpress & relayenable):Multilevelreport (withouteachlevel, justfinallevel) Manualcontrol (longpress &relaydisable):Multilevelreport (eachlevelwillbereported) |
Disabled Relay BehaviorParameter=21,Size=1Value=0 report on/off and multilevelstatus when paddle is pressed and change LED indicatorstatus and Parameter 15 is set to value 0 or 2 (output control disabled) according to setting in Parameter 20.Value=1 DONt report on/off or multilevel status or and change LED indicator status when paddle is pressed and Parameter 15 is set to value 0 or 2 (output control disabled). Default = 0 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | report on/off and multilevelstatus when paddle is pressed and change LED indicatorstatus and Parameter 15 is set to value 0 or 2 (output control disabled) according to setting in Parameter 20. |
1 | DONt report on/off or multilevel status or and change LED indicator status when paddle is pressed and Parameter 15 is set to value 0 or 2 (output control disabled) |
Night Mode Brightness LevelSet the level of brightness the dimmer will turn on to when off and lower paddle held DOWN for 2 seconds.Parameter=22,Size=1Values: 0- disable function; 1-99 %Default:: 20 Size: 1 Byte, Default Value: 20
Setting | Description |
---|---|
0 - 99 | Night Mode Brightness Level |
LED Indicator ColorParameter=23Size=1Value=0 WhiteValue=1BlueValue=2GreenValue=3RedDefault = 1 Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | White |
1 | Blue |
2 | Green |
3 | Red |
LED Indicator BrightnessParameter=24Size=1Value=0 Bright (100%)Value=1Medium (60%)Value=2Low (30%)Default =1 Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Bright (100%) |
1 | Medium (60%) |
2 | Low (30%) |
Single Tap Behavior: when switch is off and press UPPER paddle 1 time, switch turns on to x brightnessLocal Button Parameter=25Size=1Value = 0last brightness level Value = 1 custom value set in parameter 18 Value = 2 maximum brightness set in parameter 11 Value = 3 full 100% brightnessDefault = 0 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | last brightness level |
1 | custom value set in parameter 18 |
2 | maximum brightness set in parameter 11 |
3 | full 100% brightness |
Auto Turn-Off Timer--- Values: 065535 (minutes) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 65535 | Auto Turn-Off Timer |
Auto Turn-On Timer Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 65535 | Auto Turn-On Timer |
Restores state after power failureParameter=8Size=1Value=0 output offValue=1 output onValue=2out put the state after powerDefault =2 Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | output off |
1 | output on |
2 | out put the state after power |
Ramp rateLocal Button + Z-Wave> change to local and Z-Wave like in the latest ZEN30 firmware, also applies to any multilevel changes (so there should be soft transition between 20 and 80% brightness if changed from the hub for example)Parameter=9Size=1,Value=1from 0x63 to 0x00 or from 0x00 to 0x63 need 1sValue=2 from 0x63 to 0x00 or from 0x00 to 0x63 need 2s ..Value=99 from 0x63 to 0x00 or from 0x00 to 0x63 need 99sDefault = 1 Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 - 99 | from 0x63 to 0x00 or from 0x00 to 0x63 need Value s |
Hardware Platform | ZGM130 |
Device Type | Multilevel Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.00 |
Z-Wave Version | 7.13.6 |
Certification ID | ZC12-21010163 |
Z-Wave Product Id | 0x0312.0xBB00.0xBB02 |
Switch Type | Toggle |
Firmware Updatable | Updatable by Consumer by RF |
Color | White |
Electric Load Type | Dimmable LEDDimmable MLV (Magnetic)Incandescent |
Z-Wave Scene Type | Central Scene |
Security V2 | S2_UNAUTHENTICATED ,S2_AUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |