Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

Custos WWD (Wireless Water Detector) Is the smallest Z-Wave compact wireless water detector with 4 sides water detection capabilities plus integrated port for remote water sensor probe as secondary physical/logical detector, innovative design allows it to work on all orientations without worrying accidental flip, incorporated high energy density lithium battery for up to X years of battery operation life span.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Lifeline Group- Device Reset Locally Notification- Sensor Binary Report- Indicator Report- Sensor Multilevel ReportTemperature Temperature level change auto report will be sent after wakeup every time based on Configuration Parameter 0x31 Setting.- Battery Report- Heat Alarm Notification Report (0x04)- 0x00 = State idle- 0x02 = Overheatno location support -- 0x06 = Underheatno location support- Water Alarm Notification Report (0x05)- 0x00 = State idle- 0x02 = Water leak detectedno location support- Power Management Notification (0x08)- 0x00 = State Idle- 0x11 = Battery Fluid is low
2 5 - Basic Set- 0x00 = IDEL / CANCEL (Based on Configuration Parameter 0x41 Setting)- 0xFF = TRIGGERED (Based on Configuration Parameter 0x40 Setting)-0x00 = Let the water run through (Based on Configuration Parameter 0x13)-0xFF = Doesnt let the water run through. (Based on Configuration Parameter 0x12)- 0x00 = Let the water run through (Based on Configuration Parameter 0x13)- 0xFF = Doesnt let the water run through. (Based on Configuration Parameter 0x12)
3 5 - Basic Set- 0x00 = IDEL / CANCEL (Based on Configuration Parameter 0x43 Setting)- 0xFF = TRIGGERED (Based on Configuration Parameter 0x42 Setting)-0xFF = TRIGGERED (Based on Configuration Parameter 0x31 Setting)
4 5 - Basic Set- 0x00 = IDEL / CANCEL (Based on Configuration Parameter 0x45 Setting)- 0xFF = TRIGGERED (Based on Configuration Parameter 0x44 Setting)
5 5 - Basic Set- 0x00 = IDEL / CANCEL (Based on Configuration Parameter 0x47 Setting)- 0xFF = TRIGGERED (Based on Configuration Parameter 0x46 Setting)

Configuration Parameters

Parameter 16: Sensors Function Set

Sensors Function Enable / Disable
Size: 1 Byte, Default Value: 15

Setting Description
0 Built-in Water Detection Probe *(Default Enabled)
1 - 0 Remote Water Detection Probe *(Default Enabled)
2 - 0 Overheat Detection *(Default Enabled)
3 - 0 Freeze Detection *(Default Enabled)

Parameter 17: Water Leak Cancellation Report Set

Water Leak Probe Cancellation Report Set
Size: 1 Byte, Default Value: 1

Setting Description
0 Send Basic SET when Water Alarm Cancelled Either Built-in or Remote Water Detection Probe
1 - 0 Send Basic SET when Water Alarm Cancelled Built-in And Remote Water Detection Probe

Parameter 32: Battery Level Change Auto Report

Battery Level Change Value to auto report
Size: 1 Byte, Default Value: 10

Setting Description
0 Disable Battery Level Change Auto Report
1 - 63 Auto report when wake up every time. *(Default 0x0A = 10%)

Parameter 33: Battery Threshold Level Report

Battery Lower Threshold Level Report
Size: 1 Byte, Default Value: 30

Setting Description
1 - 99 Battery Lower Threshold Valve Report *(Default 30%)

Parameter 48: Temperature Report Unit

Configure Temperature Report Unit
Size: 1 Byte, Default Value: 2

Setting Description
0 Disable Temperature Report
1 - 0 Report Celsius C unit
2 - 0 Report Fahrenheit F unit

Parameter 49: Temperature Level Change Report

Temperature Level Change to auto report
Size: 2 Byte, Default Value: 260

Setting Description
0 - 255 From 0C to 255C
256 - 511 From 0F to 255F

Parameter 50: Temperature Value Offset Report

Temperature Value Offset Report Set
Size: 2 Byte, Default Value: 256

Setting Description
0 - 255 From 0C to 255C
4096 - 4351 From -1C to -255C
256 - 511 From 0F to 255F
4353 - 4607 From -1F to -255F

Parameter 51: Overheat Trigger Value

Overheat Trigger Value SET
Size: 2 Byte, Default Value: 360

Setting Description
0 - 255 From 0C to 255C
256 - 511 From 0F to 255F

Parameter 52: Overheat Cancellation Value

Overheat Cancellation Value auto report
Size: 2 Byte, Default Value: 342

Setting Description
0 - 255 From 0C to 255C
256 - 511 From 0F to 255F

Parameter 53: Freeze Trigger Value

Configure Freeze Trigger Report value
Size: 2 Byte, Default Value: 360

Setting Description
0 - 255 From 0C to 255C
256 - 511 From 0F to 255F

Parameter 54: Freeze Recover Value

Configure Freeze Recover Report Value
Size: 2 Byte, Default Value: 342

Setting Description
0 - 255 From 0C to 255C
256 - 511 From 0F to 255F

Parameter 64: AG2 - Built-in Water Leak Trigger

Built-in Water Leak Trigger Basic SET
Size: 1 Byte, Default Value: 1

Setting Description
0 Disable Basic Set (Send nothing)
1 - 0 Basic Set ON (0xFF)
2 - 0 Basic Set OFF (0x00)

Parameter 65: AG2 - Built-in Water Leak Cancellation

Built-in Water Leak Cancellation Basic SET
Size: 1 Byte, Default Value: 0

Setting Description
0 Disable Basic Set (Send nothing)
1 - 0 Basic Set ON (0xFF)
2 - 0 Basic Set OFF (0x00)

Parameter 66: AG3 - Remote Water Leak Trigger

Remote Water Leak Trigger Basic SET
Size: 1 Byte, Default Value: 1

Setting Description
0 Disable Basic Set (Send nothing)
1 - 0 Basic Set ON (0xFF)
2 - 0 Basic Set OFF (0x00)

Parameter 67: AG3 - Remote Water Leak Cancellation

Remote Water Leak Cancellation Basic SET
Size: 1 Byte, Default Value: 0

Setting Description
0 Disable Basic Set (Send nothing)
1 - 0 Basic Set ON (0xFF)
2 - 0 Basic Set OFF (0x00)

Parameter 68: AG4 - Overheat Trigger Value

Overheat Trigger Value Basic SET
Size: 1 Byte, Default Value: 0

Setting Description
0 Disable Basic Set (Send nothing)
1 - 0 Basic Set ON (0xFF)
2 - 0 Basic Set OFF (0x00)

Parameter 69: AG4 - Overheat Recover Value

Overheat Recover Value Basic SET
Size: 1 Byte, Default Value: 0

Setting Description
0 Disable Basic Set (Send nothing)
1 - 0 Basic Set ON (0xFF)
2 - 0 Basic Set OFF (0x00)

Parameter 70: AG5 - Freeze Trigger Value

Freeze Trigger Value Basic SET
Size: 1 Byte, Default Value: 0

Setting Description
0 Disable Basic Set (Send nothing)
1 - 0 Basic Set ON (0xFF)
2 - 0 Basic Set OFF (0x00)

Parameter 71: AG5 - Freeze Recover Value

Freeze Recover Value Basic SET
Size: 1 Byte, Default Value: 0

Setting Description
0 Disable Basic Set (Send nothing)
1 - 0 Basic Set ON (0xFF)
2 - 0 Basic Set OFF (0x00)

Parameter 80: Resend Water Leak Notification Time

Resend Water Leak Notification Time Set
Size: 1 Byte, Default Value: 0

Setting Description
0 Do not resend
1 - 30 1 - 30 Minutes

Parameter 96: Buzzer Related Function Actions

Buzzer Related Function Actions Set
Size: 1 Byte, Default Value: 3

Setting Description
0 Buzzer Enable responds with GSensor in action *(Default 1 = Eanbled)
1 - 0 Buzzer Enable responds with Water Leak Detection *(Default 1 = Enabled)

Parameter 97: Buzzer Sound Saving Mode

Sound works first 3S Water Leak Detected
Size: 1 Byte, Default Value: 1

Setting Description
0 Disable Saving mode (Buzzer sound works during whole Water Leak is detected)
1 - 0 Enable Saving mode (Buzzer function only works 3s when Water Leak is detected)

Technical Data

Hardware Platform ZGM130
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 1 FW: 2.00
Z-Wave Version 7.14.3
Certification ID ZC12-21010160
Z-Wave Product Id 0x0270.0x0201.0x010B
Outdoor Use ok
Frequency XXfrequency
Maximum transmission power XXantenna
Notification Sensor