Custos WWD (Wireless Water Detector) Is the smallest Z-Wave compact wireless water detector with 4 sides water detection capabilities plus integrated port for remote water sensor probe as secondary physical/logical detector, innovative design allows it to work on all orientations without worrying accidental flip, incorporated high energy density lithium battery for up to X years of battery operation life span.
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Lifeline Group- Device Reset Locally Notification- Sensor Binary Report- Indicator Report- Sensor Multilevel ReportTemperature Temperature level change auto report will be sent after wakeup every time based on Configuration Parameter 0x31 Setting.- Battery Report- Heat Alarm Notification Report (0x04)- 0x00 = State idle- 0x02 = Overheatno location support -- 0x06 = Underheatno location support- Water Alarm Notification Report (0x05)- 0x00 = State idle- 0x02 = Water leak detectedno location support- Power Management Notification (0x08)- 0x00 = State Idle- 0x11 = Battery Fluid is low |
2 | 5 | - Basic Set- 0x00 = IDEL / CANCEL (Based on Configuration Parameter 0x41 Setting)- 0xFF = TRIGGERED (Based on Configuration Parameter 0x40 Setting)-0x00 = Let the water run through (Based on Configuration Parameter 0x13)-0xFF = Doesnt let the water run through. (Based on Configuration Parameter 0x12)- 0x00 = Let the water run through (Based on Configuration Parameter 0x13)- 0xFF = Doesnt let the water run through. (Based on Configuration Parameter 0x12) |
3 | 5 | - Basic Set- 0x00 = IDEL / CANCEL (Based on Configuration Parameter 0x43 Setting)- 0xFF = TRIGGERED (Based on Configuration Parameter 0x42 Setting)-0xFF = TRIGGERED (Based on Configuration Parameter 0x31 Setting) |
4 | 5 | - Basic Set- 0x00 = IDEL / CANCEL (Based on Configuration Parameter 0x45 Setting)- 0xFF = TRIGGERED (Based on Configuration Parameter 0x44 Setting) |
5 | 5 | - Basic Set- 0x00 = IDEL / CANCEL (Based on Configuration Parameter 0x47 Setting)- 0xFF = TRIGGERED (Based on Configuration Parameter 0x46 Setting) |
Sensors Function Enable / Disable Size: 1 Byte, Default Value: 15
Setting | Description |
---|---|
0 | Built-in Water Detection Probe *(Default Enabled) |
1 - 0 | Remote Water Detection Probe *(Default Enabled) |
2 - 0 | Overheat Detection *(Default Enabled) |
3 - 0 | Freeze Detection *(Default Enabled) |
Water Leak Probe Cancellation Report Set Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Send Basic SET when Water Alarm Cancelled Either Built-in or Remote Water Detection Probe |
1 - 0 | Send Basic SET when Water Alarm Cancelled Built-in And Remote Water Detection Probe |
Battery Level Change Value to auto report Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 | Disable Battery Level Change Auto Report |
1 - 63 | Auto report when wake up every time. *(Default 0x0A = 10%) |
Battery Lower Threshold Level Report Size: 1 Byte, Default Value: 30
Setting | Description |
---|---|
1 - 99 | Battery Lower Threshold Valve Report *(Default 30%) |
Configure Temperature Report Unit Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | Disable Temperature Report |
1 - 0 | Report Celsius C unit |
2 - 0 | Report Fahrenheit F unit |
Temperature Level Change to auto report Size: 2 Byte, Default Value: 260
Setting | Description |
---|---|
0 - 255 | From 0C to 255C |
256 - 511 | From 0F to 255F |
Temperature Value Offset Report Set Size: 2 Byte, Default Value: 256
Setting | Description |
---|---|
0 - 255 | From 0C to 255C |
4096 - 4351 | From -1C to -255C |
256 - 511 | From 0F to 255F |
4353 - 4607 | From -1F to -255F |
Overheat Trigger Value SET Size: 2 Byte, Default Value: 360
Setting | Description |
---|---|
0 - 255 | From 0C to 255C |
256 - 511 | From 0F to 255F |
Overheat Cancellation Value auto report Size: 2 Byte, Default Value: 342
Setting | Description |
---|---|
0 - 255 | From 0C to 255C |
256 - 511 | From 0F to 255F |
Configure Freeze Trigger Report value Size: 2 Byte, Default Value: 360
Setting | Description |
---|---|
0 - 255 | From 0C to 255C |
256 - 511 | From 0F to 255F |
Configure Freeze Recover Report Value Size: 2 Byte, Default Value: 342
Setting | Description |
---|---|
0 - 255 | From 0C to 255C |
256 - 511 | From 0F to 255F |
Built-in Water Leak Trigger Basic SET Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable Basic Set (Send nothing) |
1 - 0 | Basic Set ON (0xFF) |
2 - 0 | Basic Set OFF (0x00) |
Built-in Water Leak Cancellation Basic SET Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable Basic Set (Send nothing) |
1 - 0 | Basic Set ON (0xFF) |
2 - 0 | Basic Set OFF (0x00) |
Remote Water Leak Trigger Basic SET Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable Basic Set (Send nothing) |
1 - 0 | Basic Set ON (0xFF) |
2 - 0 | Basic Set OFF (0x00) |
Remote Water Leak Cancellation Basic SET Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable Basic Set (Send nothing) |
1 - 0 | Basic Set ON (0xFF) |
2 - 0 | Basic Set OFF (0x00) |
Overheat Trigger Value Basic SET Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable Basic Set (Send nothing) |
1 - 0 | Basic Set ON (0xFF) |
2 - 0 | Basic Set OFF (0x00) |
Overheat Recover Value Basic SET Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable Basic Set (Send nothing) |
1 - 0 | Basic Set ON (0xFF) |
2 - 0 | Basic Set OFF (0x00) |
Freeze Trigger Value Basic SET Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable Basic Set (Send nothing) |
1 - 0 | Basic Set ON (0xFF) |
2 - 0 | Basic Set OFF (0x00) |
Freeze Recover Value Basic SET Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable Basic Set (Send nothing) |
1 - 0 | Basic Set ON (0xFF) |
2 - 0 | Basic Set OFF (0x00) |
Resend Water Leak Notification Time Set Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Do not resend |
1 - 30 | 1 - 30 Minutes |
Buzzer Related Function Actions Set Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
0 | Buzzer Enable responds with GSensor in action *(Default 1 = Eanbled) |
1 - 0 | Buzzer Enable responds with Water Leak Detection *(Default 1 = Enabled) |
Sound works first 3S Water Leak Detected Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable Saving mode (Buzzer sound works during whole Water Leak is detected) |
1 - 0 | Enable Saving mode (Buzzer function only works 3s when Water Leak is detected) |
Hardware Platform | ZGM130 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 1 FW: 2.00 |
Z-Wave Version | 7.14.3 |
Certification ID | ZC12-21010160 |
Z-Wave Product Id | 0x0270.0x0201.0x010B |
Outdoor Use | ok |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |