Quickstart

This is a secure Binary Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

Heatit ZM Single Relay is a high power relay for in-wall installations.The relay allows you to control connected devices either through your Z-Wave network or via a wired switch. The module is equipped with a 16A relay and has a scene controller functionality.The device can withstand a load of max 16A /3600W at 230VAC.The Heatit ZM Single Relay has a power metering feature that allows you to monitor the power consumption of your connected devices.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Lifeline. (Normally used by the Z-Wave Controller) Sends:
2 5 Send Basic Set commands representing the status of the internal relay when changed from S1.(0x00, 0xFF) ON/OFF
3 5 When S1 pressed/heldPress: 0x00, 0xFFHeld: Multilevel Switch Start Level Change CommandLevel Increase Start / Level Increase StopLevel Decrease Start / Level Decrease Stop
4 5 - Basic Set (S2)(0x00, 0xFF)
5 5 When S2 pressed/heldPress: 0x00 / 0xFFHeld: Multilevel Switch Start Level Change CommandLevel Increase Start / Level Increase StopLevel Decrease Start / Level Decrease StopMax nodes in group: 5

Configuration Parameters

Parameter 1: Load limit

Ensures that the device does not draw more current than rated. Immunity for power consumption peaks.
Size: 1 Byte, Default Value: 16

Setting Description
1 - 16 1-16 ampere. Default is 16 (16 ampere)

Parameter 10: Meter report interval

Time interval between consecutive meter reports. Meter reports can also be sent as a result of polling.
Size: 2 Byte, Default Value: 900

Setting Description
30 - 32767 30 seconds32767 seconds.

Parameter 11: Meter report delta value

Meter report delta value
Size: 2 Byte, Default Value: 75

Setting Description
5 - 3600 5-3600W.

Parameter 2: Power shutdown actions

Decide how the device should react when the overload/overheating features has turned relay OFF
Size: 2 Byte, Default Value: 20

Setting Description
0 Disabled and will not retry. User needs to manually turn on afterwards. If temperature overload is on, device will not turn on until device has cooled down.
1 - 32767 After power shut down (param 1) device will try to turn back ON after delay specified here. (Time in minutes)

Parameter 3: Switch Type

Decides what type of switch is connected.
Size: 1 Byte, Default Value: 0

Setting Description
0 Momentary Switch
1 Toggle Switch

Parameter 4: S1/Button operation

S1/Button operation
Size: 1 Byte, Default Value: 0

Setting Description
0 Button turns load on/off and sends Meter report + Relay status.
1 Button sends Meter report + Relay status, load can be only controlled wirelessly

Parameter 5: Scene notifications

Decides if/what scene controller notifications the device sends to gateway.
Size: 1 Byte, Default Value: 0

Setting Description
0 Sends scene controller for S2. S1 disabled
1 Sends scene controller for S1. S2 disabled
2 Sends scene controller for S1 and S2
3 Scene controller deactivated.

Parameter 6: Restore Power Level

Relay power level after power is restored from power-outage.When device is from factory/factory reset the first state of the device should be OFF
Size: 1 Byte, Default Value: 2

Setting Description
0 Always OFF on restored power
1 Always ON on restored power
2 Restore last state on restored power (Default)

Parameter 7: Automatic Turn off

Time to turn relay OFF after having been turned ON
Size: 4 Byte, Default Value: 0

Setting Description
0 Auto OFF disabled.
1 - 86400 Auto OFF timeout in seconds

Parameter 8: Automatic Turn on

Time to turn relay ON after having been turned OFF
Size: 4 Byte, Default Value: 0

Setting Description
0 Auto ON disabled.
1 - 86400 Auto ON timeout in seconds

Parameter 9: Inverted Output

Decides if the relay output should be inverted
Size: 1 Byte, Default Value: 0

Setting Description
0 Standard operation
1 Inverted Output

Technical Data

Hardware Platform ZGM130
Device Type Binary Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.00
Z-Wave Version 7.13.7
Certification ID ZC12-21010159
Z-Wave Product Id 0x019B.0x0004.0x3500
Electric Load Type ELV (Electronic)FluorescentIncandescentLEDMLV (Magnetic)
Switch Type Push Button
Neutral Wire Required ok
Firmware Updatable Updatable by Consumer by RF
Z-Wave Scene Type Central Scene
Frequency XXfrequency
Maximum transmission power XXantenna
Binary Switch