Strips Drip is an ultra-thin multi sensor and the thinnest water leakage and temperature sensor in the world, detecting the presence of water and reporting temperature levels. The thinness, up to 20 years battery life and multiple mounting possibilities makes it very versatile. Strips Drips will detect even a few drops of water and report within seconds. Strips Drip sends an alarm signal if it detects water. Its unique design allows it to be easily placed almost anywhere, generally in most places other sensors simply cant fit. With soaking pads integrated in the mounting plate even a few drops of water will be detected. The temperature reporting feature alerts occupants of potentially dangerous freezing or overheating conditions, keeping residents safe and informed. Strips Drip is a very reliable water leak sensor. The unique design and mounting plate make it easy to place nearly invisibly under sinks, in bathrooms, and under appliances to sense and report dangerous or potentially damaging conditions when connected to your Z-Wave smart home system. With a strong adhesive and mounting plate that can be screwed down, Strips Drip can be adhered securely to any surface to ensure permanent placement. Sensitivity is also adjustable and can be set per user preferences. 700 Series Drip can be used both indoors and out and the integrated custom battery gives Strips an expected lifetime of 10+ years. For you, this means no hassles needing to change or charge batteries in your Strips sensors for the lifetime of the product! Z-Wave Plus 700 series sensors bring a wealth of additional valued features such as longer range, low power consumption for extended battery life and SmartStart technology for instant enrolling. With SmartStart, device inclusion can be initiated automatically by simply removing the included magnet. The Z-Wave gateway then performs the inclusion process in the background, without the need for user interaction. 700 Series provides a direct range of 100 meters, an improvement of 60 meters over the 500 series and also includes the industrys best S2 security, providing Strips Drip with the ultimate combination of features to securely protect your home.
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Group 1, the Lifeline group, includes all signals that are sent automatically to keep a central controller notified of the status of Strips Drip 700. This includes the battery level, the moistureleakage and temperature levels, and moistureleakage, high and low temperature notifications. |
Turn the Leakage Alarm to On or Off Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Off |
1 - 0 | On |
Set the trigger level at which the Leakage Alarm Notification Report will be sent Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
1 - 100 | (1: Almost Dry, 100: Wet) |
Select the number of hours between moisture reports. Report values between -100 to 100 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 120 | Hours (Hours between reports). Default: 0 = Off |
Activate Supervision command for only important alarm events or all events. *Supervised commands require a confirmation from the gateway when a notification is received Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Off |
1 - 0 | Alarm Report (*Only for alarm events e.g. Leakage alarm) |
2 - 0 | All Reports |
Turn On or Off LED for specific event indications (ex. alarms). Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Off |
1 - 0 | On |
Turn On or Off Moisture reporting during polling (applicable only for Fibaro gateway users) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Off |
1 - 0 | On |
Should be performed when Drip is mounted correctly and absolutely dry to calibrate the u0022zero-levelu0022. A Multilevel Sensor Report with the Moisture value is sent after calibration is performed Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Device resets to this value after performing capacitance calibration and sends a report with value 0 to the gateway (as recommended by Z-Wave Specifications.) |
1 - 0 | Perform Calibration |
The offset value is used to calibrate temperature reports in the actual temperature. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-100 - 100 | [=-10.0 to +10.0 (Degree C)] |
Select the number of minutes between the temperature reports (15 minutes to 24 hours) (used for parameter 4) Size: 2 Byte, Default Value: 1440
Setting | Description |
---|---|
15 - 1440 | (minutes between reports) |
A new temperature report is sent when the temperature has changed more than the delta value. Input value converted to one decimal place Size: 1 Byte, Default Value: 20
Setting | Description |
---|---|
5 - 100 | [=0.5 to 10.0 (Degree C)], Default: 20 (= 2.0 Degree C) |
Triggers alarm clear reports (see parameters 7 & 8). Input value converted to one decimal place Size: 1 Byte, Default Value: 20
Setting | Description |
---|---|
5 - 100 | [=0.5 to 10.0 (Degree C)], Default: 20 (= 2.0 Degree C) |
Turn On or Off temperature sensor value reporting (does not affect temperature alarms) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Off |
1 - 0 | On. Reports the actual value when the temperature is changed according to parameter 26 since the last report or at least according to the reporting period set in the config parameter 25. |
2 - 0 | On. Reports the actual value periodically based on the config parameter 25. |
3 - 0 | On. The average temperature during the period is sent periodically during every wake up interval. |
Select the temperature unit Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Celsius |
1 - 0 | Fahrenheit |
Turn On or Off the temperature alarm Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Off |
1 - 0 | On |
Select a high temperature alarm level Size: 1 Byte, Default Value: 40
Setting | Description |
---|---|
-20 - 80 | (Degree C) |
Select a low temperature alarm level Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
-20 - 60 | (Degree C) |
Hardware Platform | ZGM130 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 2 FW: 6.22 |
Z-Wave Version | 7.13.3 |
Certification ID | ZC12-21010155 |
Z-Wave Product Id | 0x019A.0x0004.0x000B |
Color | White |
Firmware Updatable | Updatable by Consumer by RF |
Outdoor Use | ok |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |