This is a secure Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

Heighten your senses with the Jasco Z-Wave Plus Flood/Freeze Sensor. When paired with a compatible hub, the smart sensor provides notification when water levels or temperatures change. Z-Wave devices can also be activated wirelessly for increased convenience and peace of mind. Your automation possibilities are seemingly infinite when connected to a compatible hub. Trigger eventsThe sensor communicates with your hub to initiate desired actions of Z-Wave devices. Increase peace of mind by automatically turning on lights, sending a notification to your phone, activating an alarm or more when temperatures or water levels change. Detection alarmBuilt-in speaker emits audible alert when water levels or temperatures change to allow immediate action by anyone in the area. Dual functionBase contacts and a detachable probe accommodate various setups. Recessed contacts on the base of the sensor are ideal for placement on flat surfaces. The included probe extends reach for use in wells, sump pump holes and other small spaces. Temperature sensorIn temperature-sensitive spaces, protect against costly damage caused by freezing or overheating. Indicator lightLED indicator displays status and provides feedback during programming. It also serves as notification if tampering with the sensor occurs. Universal compatibilityZ-Wave Plus and all previous Z-Wave generations work together to allow continued expansion of your home-automation network.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Association Group 1 supports Lifeline, Notification, and Device Reset Locally.

Configuration Parameters

Parameter 19: Alternate Exclusion

Alternative way to perform Exclusion
Size: 2 Byte, Default Value: 0

Setting Description
0 Press button once when prompted to remove device
1 Press the button three times quickly when prompted to remove device

Parameter 21: Reverse Wet/Dry Detection

Detection Mode(1:Wet 2:Dry)
Size: 2 Byte, Default Value: 1

Setting Description
1 Normal Detection (water detected)
2 Reverse Detection (Dry Detected)

Parameter 22: Temp Report Freq.(Battery)

Set Temp Report Freq.
Size: 2 Byte, Default Value: 60

Setting Description
5 - 59 5... 59 minutes
60 Hourly
360 6 hours
720 12 hours
1440 Daily

Parameter 23: Battery Report Freq.

Set Battery Report Freq.
Size: 2 Byte, Default Value: 1440

Setting Description
5 - 60 5... 60 minutes
360 Hourly
720 12 hours
1440 Daily

Parameter 50: Low Temp Alert Level

Set Low Temp Level
Size: 2 Byte, Default Value: 33

Setting Description
-4 - 122 Low Temp

Parameter 51: High Temp Alert Level

Set High Temp Level
Size: 2 Byte, Default Value: 104

Setting Description
-4 - 122 High temp

Parameter 52: Temp Report Freq.(USB)

Set Temp Report Freq.
Size: 2 Byte, Default Value: 60

Setting Description
5 - 360 5... 360 Minutes - Sent every 5 minutes, up to 6 hours
60 Hourly

Parameter 53: LED/Buzzer action during Tamper Event

Set Tamper Indication0 = no LED, no beep (Default)1 = Red LED Flash 5x, no beep2 = Red LED cont flash, no beep3 = no LED, cont beep4 = Red LED cont flash, cont beep
Size: 2 Byte, Default Value: 0

Setting Description
0 No LED, No Beep
1 Red LED Flash 5x, no beep
2 Red LED continuous flash, no beep
3 No LED, continuous beep
4 Red LED continuous flash, continuous beep

Technical Data

Hardware Platform ZGM130
Device Type Notification Sensor
Network Operation Always On Slave
Firmware Version HW: 1 FW: 7.06
Z-Wave Version 7.13.5
Certification ID ZC12-20120146
Z-Wave Product Id 0x0063.0x4953.0x3430
Firmware Updatable
Frequency XXfrequency
Maximum transmission power XXantenna
Notification Sensor