This is a
iblinds is a simple Z-Wave Plus device used to automate your existing window blinds. You can control any 2-2inch corded lift horizontal blinds in your home or office. Set a scheduled to open at sunrise and close at sunset, use voice control with Amazon Alexa and Google Home or manually control a single blind, or a group of them, from home or anywhere in the world with one touch of a button using your smartphone, tablet or Z-Wave remote.
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Battery and Switch Multilevel lifeline reports |
Used for auto calibration. Sets interval endpoint detection. Smaller interval will make the blinds close tighter. Size: 1 Byte, Default Value: 22
Setting | Description |
---|---|
15 - 30 | Smaller interval will make the blinds close tighter |
Used to reverse the direction of the blinds. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Forward Direction - 0% = Closed Down |
1 | Reverse Direction - 0% = Closed Up |
Used to disable Z-Wave Report. This is useful for systems that poll iblinds immediately after sending a position command. Disable if this an immediate report is causing iblinds motor to function improperly. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Enable Device Reset Locally |
1 | Disable Device Reset Locally |
Used to set the default ON Level when manual push button is pushed- Default value for ON = 50% (0x32) , change this value if you wish to set the push button ON value to a different preset value. Size: 1 Byte, Default Value: 50
Setting | Description |
---|---|
0 - 99 | Set the default On Value |
Reserved for Manufactuer Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Reserved for Manufactuer |
Used to set the default blind Speed. 0= No Delay. The Larger the number the slower the speed. Note: Duration Value >0 will always override the speed parameter Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 100 | The larger the value the slower the speed |
Hardware Platform | ZGM130 |
Device Type | Window Covering DT |
Network Operation | Listening Sleeping Slave |
Firmware Version | HW: 1 FW: 3.01 |
Z-Wave Version | 7.12.2 |
Certification ID | ZC12-20110129 |
Z-Wave Product Id | 0x0287.0x0004.0x0071 |
Window Covering Control Features | Automatic CalibrationEndpoint AwarePosition AwareSupports Horizontal Blinds/LouversSupports Tilt Motion |
Firmware Updatable | Updatable by Consumer by RF |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |