Quickstart

This is a secure Alarm Sensor for . Please make sure the internal battery is fully charged.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.

This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.

If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.

Product Description

The Water Sensor 7 pro brings more safety into your home. With its flexible sensor probe and the sensitive sensor point it detects the presence and absence of water at any given location. Furthermore the Watersensor 7 pro is enabled to accurately measure the temperature and humidity of its environment, so you are always informed about your room climate. Thanks to the latest Z-Wave 700 series technology, the Water Sensor 7 is distinguished with and increased range, S2 Security, OTA FW update and SmartStart.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association - one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.

Association Groups:

Group Number Maximum Nodes Description
1 5 Lifeline association to gateways
2 5 Control devices when water leakage is detected
3 5 Sends out alarm message when water leakage is detected
4 5 Sends out alarm messages when tamper is tripped

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.

IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.

Parameter 10: Time Delay of u0022Offu0022 command frame

Off command is sent after a delay defined in this parameter.
Size: 2 Byte, Default Value: 0

Setting Description
0 - 32400 seconds

Parameter 11: Delay of Tamper Alarm Cancellation

Time a tamper alarm is delayed.
Size: 2 Byte, Default Value: 0

Setting Description
0 - 32400 seconds

Parameter 12: Reporting Tamper Alarm Cancellation

This parameter defines if the alarm cancellation event is reported.
Size: 1 Byte, Default Value: 1

Setting Description
0 Do not send Report
1 - 0 Send Report

Parameter 16: Minimum Temperature change to report

This value defines the minimum change of temperature to cause an unsolicited report of humidity to the central controller using Lifeline.If the value is set to 0, there will be no reports sent to the controller, when the temperature changes. However, periodic reports, managed by configuration parameter 18, may still be active.
Size: 1 Byte, Default Value: 20

Setting Description
0 Disabled
1 - 100 1/10 degree

Parameter 17: Minimum humidity change to report

This value defines the minimum change of humidity to cause an unsolicited report of humidity to the central controller using Lifeline.If the value is set to 0, there will be no reports sent to the controller, when the humidity changes. However, periodic reports, managed by configuration parameter 18, may still be active.
Size: 1 Byte, Default Value: 5

Setting Description
0 Disabled
1 - 20 %

Parameter 18: Temperature and Humidity Periodic Reports

This parameter defines the time interval to send an unsolicited report.If the value is set to 0, there will be no periodic reports sent to the controller. However, reports on temperature/humidity changes, managed by configuration parameters 16 and 17, may still be active.
Size: 2 Byte, Default Value: 43200

Setting Description
0 Disabled
900 - 65535 Seconds

Parameter 255: Reset Parameter

This parameter helps reset configuration parameters and the device to factory defaults1 - 1431655764 (0x55555554) - Reset all Parameter settings to their default settings.1431655765 - Completely factory reset sensor and send device reset locally notification.
Size: 4 Byte, Default Value: 0

Setting Description
1 - 1431655764 Reset all Parameter settings to their default settings.
1431655765 Completely factory reset sensor and send device reset locally notification.

Parameter 3: Visual LED Indications

This parameter defines when LEDs will indicate events. Disabling all indications may extend battery life.Value 0 means - No Indications.
Size: 1 Byte, Default Value: 7

Setting Description
1 - 0 Water Leakage Status Change
2 - 0 Wake Up
3 - 0 Water Leakage Status Change + Wake Up (values 1 + 2)
4 - 0 Device Tampering
5 - 0 Water Leakage Status Change + Device Tampering (values 1 + 4)
6 - 0 Wake Up + Device Tampering (values 2 + 4)
7 - 0 All LED indications on (values 1 + 2 + 4 summarized)

Parameter 4: Range Test after double click

Allows to enable the activation of a Z-Wave range test with double clicking the tamper switch.
Size: 1 Byte, Default Value: 0

Setting Description
0 Disabled
1 - 0 Enabled

Parameter 5: 2nd Association Group Trigger

This parameter defines the status of the magnet switch that causes sending a BASIC command to all devices of Association Group 2.
Size: 1 Byte, Default Value: 0

Setting Description
0 Switch after Water Leakage Start and Stop
1 - 0 Switch after Water Leakage Start and Stop
2 - 0 Switch after Water Leakage Start and Stop

Parameter 6: Command Sent to Devices of Association Group 2

This parameter defines which commands is sent to 2nd Association Group
Size: 1 Byte, Default Value: 2

Setting Description
0 On
1 - 0 Off
2 - 0 On and Off

Parameter 7: BASIC command u0022On eventu0022 value

This is the BASIC command value sent in case of u0022Onu0022 event.
Size: 1 Byte, Default Value: 255

Setting Description
0 - 99 Value
255 Value

Parameter 8: BASIC command u0022Off eventu0022 value

This is the BASIC command value sent in case of u0022Offu0022 event.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 99 Value
255 Value

Parameter 9: Time Delay of u0022Onu0022 command frame

On command is sent after a delay defined in this parameter.
Size: 2 Byte, Default Value: 0

Setting Description
0 - 32400 seconds

Technical Data

Hardware Platform ZGM130
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 1 FW: 0.00
Z-Wave Version 7.12.2
Certification ID ZC12-20080098
Z-Wave Product Id 0x0371.0x0102.0x0013
Color White
Firmware Updatable Updatable by Consumer by RF
Security V2 S2_UNAUTHENTICATED ,S2_AUTHENTICATED
Frequency XXfrequency
Maximum transmission power XXantenna

Supported Command Classes

  • Association Grp Info V3
  • Association V2
  • Battery
  • Configuration V4
  • Device Reset Locally
  • Firmware Update Md V5
  • Indicator V3
  • Manufacturer Specific V2
  • Multi Channel Association V3
  • Notification V8
  • Powerlevel
  • Security 2
  • Sensor Multilevel V11
  • Supervision
  • Transport Service V2
  • Version V3
  • Wake Up V2
  • Zwaveplus Info V2

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network. Controllers are typically Gateways,Remote Controls or battery operated wall controllers.
  • Slave — is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators and even remote controls.
  • Primary Controller — is the central organizer of the network. It must be a controller. There can be only one primary controller in a Z-Wave network.
  • Inclusion — is the process of adding new Z-Wave devices into a network.
  • Exclusion — is the process of removing Z-Wave devices from the network.
  • Association — is a control relationship between a controlling device and a controlled device.
  • Wakeup Notification — is a special wireless message issued by a Z-Wave device to announces that is able to communicate.
  • Node Information Frame — is a special wireless message issued by a Z-Wave device to announce its capabilities and functions.