This is a
Reset to factory default | Keep the button pressed for 10 seconds. Then the green LED will start blinking. Release the button, when the LED stops blinking. Your device is reset to factory default now. |
Inclusion | 1. Insert the battery.
2. Press the button quickly three times in a row. |
Exclusion | 1. Press the button quickly three times in a row. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | Wake Up the device by pressing the central button once. |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Lifeline |
2 | 5 | Temperature High Trigger |
3 | 5 | Temperature Low Trigger |
4 | 5 | Humidity High Trigger |
5 | 5 | Humidity Low Trigger |
6 | 5 | Air Temperature |
This value defines the minimum change of temperature to cause an unsolicited report of humidity to the central controller using Lifeline. If the value is set to 0, there will be no reports sent to the controller, when the temperature changes. However, periodic reports, managed by configuration parameter 4, may still be active. Size: 1 Byte, Default Value: 20
Setting | Description |
---|---|
0 | disabled |
1 - 100 | 1/10 degree |
This value defines the minimum change of humidity to cause an unsolicited report of humidity to the central controller using Lifeline. If the value is set to 0, there will be no reports sent to the controller, when the humidity changes. However, periodic reports, managed by configuration parameter 4, may still be active. Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 | disabled |
1 - 20 | % |
This value determines how often aerQ Sensor checks for minimum change in temperature or humidity on Parameter 1 and 2 or when the Sensor wakes up by button pressing. Size: 1 Byte, Default Value: 15
Setting | Description |
---|---|
1 - 255 | Minutes |
This parameter defines the time interval to send an unsolicited report. If the value is set to 0, there will be no periodic reports sent to the controller. However, reports on temperature/humidity changes, managed by configuration parameters 1 and 2, may still be active. Size: 2 Byte, Default Value: 43200
Setting | Description |
---|---|
0 | disabled |
30 - 65535 | Seconds |
This parameter defines a temperature. If the measured temperature surpasses this watermark a BASIC command is sent into Association Group 2 Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | disabled |
1 - 1000 | 1/10 degree |
This parameter defines a temperature. If the measured temperature dropps below this watermark a BASIC command is sent into Association Group 3 Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | disabled |
200 - 1000 | 1/10 degree |
This parameter defines a relative humidity. If the measured relative humidity surpasses this watermark a BASIC command is sent into Association Group 4 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | disabled |
1 - 90 | % |
This parameter defines a relative humidity. If the measured temperature dropps below this relative humidity a BASIC command is sent into Association Group 5 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | disabled |
1 - 90 | % |
This defines what BASIC command shall be sent out into association group 3 Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 - 255 | Value |
This defines what BASIC command shall be sent out into association group 2 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 255 | Value |
This defines what BASIC command shall be sent out into association group 5 Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 - 255 | Value |
This defines what BASIC command shall be sent out into association group 4 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 255 | Value |
This value allows to increase the humidity threshold for mold danger notification by max 10% Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 10 | % |
Can add or minus this setting value to calibrate temperature when checked. Scale is defined by Param 64. e.g. Value 15 means 1.5C or 1.5F. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
-200 - 200 | -20 - 20 ° Steps 0,1° |
Can add or minus this setting value to calibrate temperature when checked. Scale is defined by Param 64. e.g. Value 15 means 1.5C or 1.5F. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-50 - 50 | % |
This value determines how often aerQ Sensor checks for upper/lower watermark value in temperature or humidity on Parameter 5 ,6,7 and 8. Size: 1 Byte, Default Value: 15
Setting | Description |
---|---|
1 - 255 | Minutes |
This parameter sets the temperature scale. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | Celsius |
2 | Fahrenheit |
This value determines which sensor report will be sent after the inclusion is complete.
1+2+4+8 =15
Size: 1 Byte, Default Value: 15
Setting | Description |
---|---|
1 | Battery Report |
2 | Temperature sensor report |
4 | Humidity Sensor report |
8 | Dew point sensor report |
This parameter helps reset configuration parameters and the device to factory defaults Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1 - 4294967294 | Reset all Parameter settings to their default settings. |
4294967295 | Completely factory reset sensor and send device reset locally notification. |
Dimensions | 34 x 34 x 16 mm |
Hardware Platform | ZGM130S |
EAN | 1220000017054 |
IP Class | IP 20 |
Voltage | 3V |
Battery Type | 1 * CR2477 |
Device Type | Notification Sensor |
Generic Device Class | GENERIC TYPE SENSOR NOTIFICATION (0x07) |
Specific Device Class | SPECIFIC TYPE NOTIFICATION SENSOR (0x01) |
Network Operation | Reporting Sleeping Slave |
Firmware Version | 02.00 |
Z-Wave Version | 07.15.1.0 |
Certification ID | ZC12-20080086 |
Z-Wave Product Id | 881.2.9 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |