Quickstart

This is a secure SPECIFIC TYPE NOTIFICATION SENSOR (0x01) for XXXQFrequencyName. To run this device please insert fresh 1 * CR2477 batteries. To run this device please make sure the internal battery is fully charged. Tripple clicking the central button includes (adds) and excludes (removes) the device. A click on the central button will wake up the device. The device supports the Security S2 framework with unauthenticated and authenticated network keys. Please follow the instructions on the central controller when including. The device also supports Smart Start. Please scan the QR code on the outlet cover of the device and your controller will add the device automatically when powered up.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

This device measures the three air quality parameters temperature, humidity and dew point and reports them to a central controller. Besides this, the device can directly control groups of other Z-Wave devices on over- and undershooting a set temperature and/or humidity parameter. This can be used to establish control loops for temperature and humidity. The device wakes up every 15 minutes to measure the values and it will send unsolicited reports when values change. Additionally, the device will report all values on request.
The mold detector is actively monitoring the danger of mold in a room based on the temperature and humidity and will issue alarm warnings when critical air conditions met. Wireless Alarm and red and a green blinking LED will indicate a mold condition. This local LED warning function is also available when the device is not included in any Z-Wave network and works stand alone.

Installation

Just place the device on any flat surface. Please keep in mind that the temperature may be different in different locations inside the room. If placed too close to the heating both temperature, humidity and dew point values may be wrong. The device is IP 20 rated. This means that is must not be exposed to direct water (rain). It is safe to use the device in a humid environment such as a bathroom or dedicated washing facility.

Product Usage

Once the device is powered up it will start monitoring the air parameters and warn of mold using the local red and green LED. All air parameters are measured every 15 minutes. Pushing the button will force an immediate measurement and the LEDs will indicate the danger of mold

  • green: no danger of mold in the room
  • red: danger of mold, open the windows to lower the humidity
The device contains two sensors with the following accuracy measures:
  • Relavity Humidity: precision ± 3% RH (max),  range 0 to 80% RH
  • Temperature: precision  ±0.4 °C (max), range  0 to 65 °C
  • Dew Point: precision  ±0.4 °C (max), range  0 to 65 °C (calculated from other sensor values)
The device sends the following notifications to the central controller:
  • Weather Alarm - Moisture Alarm(0x10 - 0x02)
  • Power management - Replace battery now(0x08 - 0x0b)
  • Heat Alarm - Overheat Unknown Location(0x04 - 0x02)
  • Heat Alarm - Underheat Unknown Location(0x04 - 0x05)

For get the status of the device on the network you need insert a battery to device. And you see result: - "The GREEN LED will blink one time in case of success or RED LED will blink five times in case of failure".

Reset to factory default Keep the button pressed for 10 seconds. After 5 seconds the red LED will start blinking.
Inclusion 1. Insert the battery.
2. Press the button quickly three times in a row.
Exclusion 1. Press the button quickly three times in a row.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate Wake Up the device by pressing the central button once.
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Lifeline
2 5 Temperature High Trigger
3 5 Temperature Low Trigger
4 5 Humidity High Trigger
5 5 Humidity Low Trigger
6 5 Air Temperature

Configuration Parameters

Parameter 1: Minimum Temperature change to report

This value defines the minimum change of temperature to cause an unsolicited report of humidity to the central controller using Lifeline. If the value is set to 0, there will be no reports sent to the controller, when the temperature changes. However, periodic reports, managed by configuration parameter 4, may still be active.
Size: 1 Byte, Default Value: 20

Setting Description
0 disabled
1 - 100 1/10 degree

Parameter 2: Minimum humidity change to report

This value defines the minimum change of humidity to cause an unsolicited report of humidity to the central controller using Lifeline. If the value is set to 0, there will be no reports sent to the controller, when the humidity changes. However, periodic reports, managed by configuration parameter 4, may still be active.
Size: 1 Byte, Default Value: 5

Setting Description
0 disabled
1 - 20 %

Parameter 4: Periodic Reports

This parameter defines the time interval to send an unsolicited report. If the value is set to 0, there will be no periodic reports sent to the controller. However, reports on temperature/humidity changes, managed by configuration parameters 1 and 2, may still be active.
Size: 2 Byte, Default Value: 43200

Setting Description
0 disabled
900 - 65535 Seconds

Parameter 5: Temperature Upper Watermark value

This parameter defines a temperature. If the measured temperature surpasses this watermark a BASIC command is sent into Association Group 2
Size: 2 Byte, Default Value: 0

Setting Description
0 disabled
1 - 1000 1/10 degree

Parameter 6: Temperature Lower Watermark value

This parameter defines a temperature. If the measured temperature dropps below this watermark a BASIC command is sent into Association Group 3
Size: 2 Byte, Default Value: 0

Setting Description
0 disabled
200 - 1000 1/10 degree

Parameter 7: Humidity Upper Watermark value

This parameter defines a relative humidity. If the measured relative humidity surpasses this watermark a BASIC command is sent into Association Group 4
Size: 1 Byte, Default Value: 0

Setting Description
0 disabled
1 - 90 %

Parameter 8: Humidity Lower Watermark value

This parameter defines a relative humidity. If the measured temperature dropps below this relative humidity a BASIC command is sent into Association Group 5
Size: 1 Byte, Default Value: 0

Setting Description
0 disabled
1 - 90 %

Parameter 9: Low Temperature Trigger BASIC Set Command Value

This defines what BASIC command shall be sent out into association group 3
Size: 1 Byte, Default Value: 255

Setting Description
0 - 255 Value

Parameter 10: High Temperature Trigger BASIC Set Command Value

This defines what BASIC command shall be sent out into association group 2
Size: 1 Byte, Default Value: 0

Setting Description
0 - 255 Value

Parameter 11: Low Humidity Trigger BASIC Set Command Value

This defines what BASIC command shall be sent out into association group 5
Size: 1 Byte, Default Value: 255

Setting Description
0 - 255 Value

Parameter 12: High Humidity Trigger BASIC Set Command Value

This defines what BASIC command shall be sent out into association group 4
Size: 1 Byte, Default Value: 0

Setting Description
0 - 255 Value

Parameter 13: Offset value for Mold danger notification

This value allows to increase the humidity threshold for mold danger notification by max 10%
Size: 1 Byte, Default Value: 0

Setting Description
0 - 10 %

Parameter 64: Temperature Scale

This parameter sets the temperature scale.
Size: 1 Byte, Default Value: 1

Setting Description
1 Celsius
2 Fahrenheit

Parameter 255: Reset Parameter

This parameter helps reset configuration parameters and the device to factory defaults
Size: 4 Byte, Default Value: 0

Setting Description
1 - 1431655764 Reset all Parameter settings to their default settings.
1431655765 Completely factory reset sensor and send device reset locally notification.

Technical Data

Dimensions 34x34x16 mm
Hardware Platform ZGM130S
EAN 1220000016644
IP Class IP 20
Battery Type 1 * CR2477
Device Type Notification Sensor
Generic Device Class GENERIC TYPE SENSOR NOTIFICATION (0x07)
Specific Device Class SPECIFIC TYPE NOTIFICATION SENSOR (0x01)
Network Operation Reporting Sleeping Slave
Firmware Version 01.00
Z-Wave Version 07.12
Certification ID ZC12-20080086
Z-Wave Product Id 0371.0002.0009
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeNotification Sensor