This is a
Aeotec Door/ Window Sensor 7 Pro is built on the 700 series Z-Wave technology. Its a small window position sensor for your smart home, it monitors window and their exact opening position and lets your know when a window is tilted or completely opened. It also supports connecting external binary sensors with a dry contact through the dry binary contact of the Door/ Window sensor. Using the latest technology it supports the highest Z-Wave security level of S2 and SmartStart.
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Lifeline to Gateway |
2 | 5 | Control devices when a magnet or external dry contacts trips |
3 | 5 | Sends out alarm message when a magnet or external dry sensor trips |
4 | 5 | Sends alarm messages when tamper is tripped |
5 | 5 | Control devices when tilting sensor trips |
This parameter defines if the internal magnet sensor or the external terminal input is detected and used to issue alarm notification. There is always one input active only. The other sensor input the deactivated. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Internal Magnet Sensor Used and scene activation enabled |
1 - 0 | External Terminal Inputs Used and scene activation disabled |
On command is sent after a delay defined in this parameter. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 32400 | seconds |
Off command is sent after a delay defined in this parameter. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 32400 | seconds |
Time a tamper alarm is delayed. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 32400 | seconds |
This parameter defines if the alarm cancellation event is reported. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Do not send Report |
1 - 0 | Send Report |
This parameter enables/disablesthe central scene function. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disabled |
1 - 0 | Enabled |
This parameter enables/disablesthe tilt function. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disabled |
1 - 0 | Enabled |
This parameter allows to set in what state is door/window when the tilt is in an OFF state. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | OFF when sensor is vertical |
1 - 0 | ON when sensor is vertical |
Parameter defines events which result in sending On/Off commands to devices added to the 2nd Association Group. These commands are sent alternately to switch the devices On and Off. Commands represent the values of BASIC SET command frames. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Switch after Open and Close |
1 | Switch after Open |
2 | Switch after Close |
Command frames sent to devices added to the 5th association group. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | On |
1 | Off |
2 | On and Off |
The value of 0 turns OFF the device, 255 turns it On. In case of associating the Dimmer or Roller Shutter module, values 1-99 allow to set an Associated device to a specified level.0-99 or 255 Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 - 99 | Value |
255 | Value |
Parameter defines how dry contact will operate with the sensor or switch that is connected to the dry contact terminals.0 - NO Toggle / Follow state will follow the input of the dry contact terminals where OFF is CLOSED, and ON is OPEN.1 - NC Toggle / Follow state will follow the input of the dry contact terminals where ON is CLOSED, and OFF is OPEN.2 - NO save state will allow state of sensor to toggle OPEN/CLOSE based on OFF to ON signal.3 - NC save state will allow state of sensor to toggle OPEN/CLOSE based on ON toOFF signal. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | NO Toggle / Follow state will follow the input of the dry contact terminals where OFF is CLOSED, and ON is OPEN. |
1 | NC Toggle / Follow state will follow the input of the dry contact terminals where ON is CLOSED, and OFF is OPEN. |
2 | NO save state will allow state of sensor to toggle OPEN/CLOSE based on OFF to ON signal. |
3 | NC save state will allow state of sensor to toggle OPEN/CLOSE based on ON toOFF signal. |
You can use this parameter to adjust the tilt sensitivity if the tilt is too low or too high. Size: 1 Byte, Default Value: 50
Setting | Description |
---|---|
1 - 100 | Tilt Sensitivity |
0Nothing happens0x55555555Completely factory reset sensor and send device reset locally notification.All other valuesReset all Parameter settings to their default settings. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1 - 1431655764 | Reset all Parameter settings to their default settings. |
1431655765 | Completely factory reset sensor and send device reset locally notification. |
This parameter defines the polarity of the magnet sensor. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Closed when Magnet near |
1 - 0 | Opened when Magnet near |
This parameter defines when the red LED will indicate events. Disabling all indications may extend battery life. Size: 1 Byte, Default Value: 7
Setting | Description |
---|---|
0 | LED indication Off |
1 - 0 | Open/Close Status Change |
2 - 0 | Wake Up |
3 - 0 | Open/Close Status Change + Wake Up (1+2 summarized) |
4 - 0 | Device Tampering |
5 - 0 | Open/Close Status Change + Device Tampering (1 + 5 summarized) |
6 - 0 | Wake Up + Device Tampering (2 + 4 summarized) |
7 - 0 | All LED indications on (values 1 + 2 + 4 summarized) |
Allows to enable the activation of a Z-Wave range test with double clicking the tamper switch. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disabled |
1 - 0 | Enabled |
This parameter defines the status of the magnet switch that causes sending a BASIC command to all devices of Association Group 2. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Switch after Open and Close |
1 - 0 | Switch after Open |
2 - 0 | Switch after Close |
This parameter defines which commands is sent to 2nd Association Group Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | On |
1 - 0 | Off |
2 - 0 | On and Off |
This is the BASIC command value sent in case of u0022Onu0022 event. Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 - 99 | Value |
255 | Value |
This is the BASIC command value sent in case of u0022Offu0022 event. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 99 | Value |
255 | Value |
Hardware Platform | ZGM130 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 1 FW: 1.00 |
Z-Wave Version | 7.12.2 |
Certification ID | ZC12-20080085 |
Z-Wave Product Id | 0x0371.0x0102.0x000C |
Color | White |
Z-Wave Scene Type | Central Scene |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |