In external supply mode, the device indicates commands status and can receive indications from the Z-Wave controller (using Indicator CC), including Identification.
Device configuration is updated immediately.
To enable the external supply mode, make sure that the external supply is connected and powered, then add the device to the Z-Wave network (remove beforehand if already added).
In battery mode, the device indicates commands status, but cannot receive indications from the Z-Wave controller (using Indicator CC), except for Identification.
The device needs to be woken up to change its configuration.
The battery level (in percent) is measured during every power-up and periodically every 24h, the measured value is reported to the controller during every power-up and when it changes by at least 5%.
To enable the battery mode, make sure that the device is powered only using the battery, then add the device to the Z-Wave network (remove beforehand if already added).
The device is equipped with a built-in temperature sensor. It measures the ambient temperature and reports it to the controller only when it changes by at least 0.1°C, but not more often than every 10 minutes. It is recommended to use battery or 12V DC power supply for reliable temperature measurement.
Operating modes
Scene Controller
This mode is enabled by default or by setting parameter 20 to 0.
In this mode, the device can activate scenes in the Z-Wave controller by sending scene ID and attribute of a specific action (using Central Scene Command Class). Associations do not work in this mode.
Double Button Mode
This mode is enabled by setting parameter 20 to 1.
In this mode, the device works as two separate buttons and it uses associations to control other Z-Wave devices (groups 2-5). You can control multiple devices of different types in this mode. Every button can control different group of devices.
1st button - controls 2nd and 3rd group:
- Click - alternately ON with last level / OFF,
- 2xClick - send pre-set level (set in parameter 152),
- Hold - alternately increasing/decreasing level until released.
2nd button - controls 4th and 5th group:
- Click - alternately ON with last level / OFF,
- 2xClick - send pre-set level (set in parameter 153),
- Hold - alternately increasing/decreasing level until released.
Single Button Mode
This mode is enabled by setting parameter 20 to 2.
In this mode, the device works as one logical button and it uses associations to control other Z-Wave devices (groups 2-3). You can control multiple devices of different types in this mode.
1st and 2nd button work in the same way:
- Click - alternately ON with last level / OFF,
- 2xClick - send pre-set level (set in parameter 152),
- Hold - alternately increasing/decreasing level until released.
Switch Controller
This mode is enabled by setting parameter 20 to 3.
In this mode, the device uses associations to control Z-Wave binary switches (group 6).
- Click 1st - ON,
- Click 2nd - OFF.
Dimmer / Roller Shutter Controller
This mode is enabled by setting parameter 20 to 4.
In this mode, the device uses associations to control Z-Wave dimmers and rollers shutters (group 6).
1st button - turns ON and increases level:
- Click - ON with the last level,
- Hold - increasing level until released,
- 2xClick - send pre-set level (set in parameter 152).
2nd button - turns OFF and decreases level:
- Click - OFF,
- Hold - decreasing level until released.
Roller Shutter Step-By-Step Controller
This mode is enabled by setting parameter 20 to 5.
In this mode, the device uses associations to control Z-Wave roller shutter controllers (group 6) in Step-By-Step mode (alternately sends commands for movement and stopping).
1st button - opens and stops:
- Click - open/stop,
- 2xClick - send pre-set level (set in parameter 152).
2nd button - closes and stops:
- Click - close/stop,
- 2xClick - stop.
Venetian blinds Step-By-Step Controller
This mode is enabled by setting parameter 20 to 6.
In this mode, the device uses associations to control Z-Wave Venetian blinds (with slats) controllers (groups 6-7) in Step-By-Step mode (alternately sends commands for movement and stopping).
1st button - opens and stops:
- Click - open/stop,
- 2xClick - send pre-set level (set in parameter 152),
- Hold - opening slats until released.
2nd button - closes and stops:
- Click - close/stop,
- 2xClick - stop,
- Hold - closing slats until released.
Visual indications
The built-in LED light shows current device status.
After powering the device:
- Green - device added to a Z-Wave network (non-secure, S0, S2 non-authenticated),
- Magenta - device added to a Z-Wave network (Security S2 Authenticated),
- Red - device not added to a Z-Wave network.
Update:
- Blinking cyan - update in progress,
- Green - update successful,
- Red - update not successful.
Command status:
The device displays current command status in response to clicking/holding the button.
- Green for 2 seconds - command acknowledged,
- Red for 2 seconds - command not acknowledged.
Identification:
The Z-Wave controller can identify this device by signalling with LED ring (using Indicator CC).
Custom indications:
In external supply mode, the user can use the LED ring to display custom indications. Using the Z-Wave controller user can specify on which half of the ring to indicate, number of blinks and timing (using Indicator CC). Brightness and colour of the indications is specified in parameters 13, 150 and 151.
Menu
Menu allows to perform Z-Wave network actions. In order to use the menu:
- Quickly, three times click, then press and hold one of the buttons.
- After 3 seconds LED ring signals adding status:
- Blinking green - entering the menu (added as non-secure, S0, S2 non-authenticated)
- Blinking magenta - entering the menu (added as Security S2 Authenticated)
- Blinking red - entering the menu (not added to a Z-Wave network)
- The LED ring will turn off for 3 seconds, then start signalling menu positions.
- Release the button when device signals desired position with colour:
- WHITE - wake up the device
- GREEN - start learning mode (add/remove)
- MAGENTA - test Z-Wave range
- CYAN - show battery level
- Green - 50-100%
- Yellow - 16-49%
- Red - 1-15%
- YELLOW - reset to factory defaults