Quickstart

This is a secure Central Scene Device for XXXQFrequencyName. To run this device please insert fresh 1 * ER14250 batteries. To run this device please make sure the internal battery is fully charged.

  1. To use SmartStart your controller needs to support Security S2 (see the controller’s manual).
  2. Enter the full DSK string code to your controller. If your controller is capable of QR scanning, scan the QR code placed on the label on the box.
  3. Power the device.
  4. Wait for the adding process to start (up to few minutes), which is signalled with yellow LED blinking.
  5. Adding result will be confirmed by the Z-Wave controller’s message and the LED frame:
    • Green – successful (non-secure, S0, S2 non-authenticated),
    • Magenta – successful (Security S2 Authenticated),
    • Red – not successful.


Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

FIBARO Walli Controller is a smart wall-mounted Z-Wave remote controller that can activate scenes or control other Z-Wave devices via associations.

Installation

Before installation

You can install the device on any smooth surface using included adhesive tape or on a mounting box using screws.

The device will select the powering mode during adding to the Z-Wave network, prioritizing external power supply if connected. To change the mode after adding, you must remove it, change the installation accordingly, then add the device again.

The device features a built-in temperature sensor, for accurate temperature readings, install the device far from sources of heat (e.g. radiators, power supplies).

Do not use the double-sided adhesive tape when mounting the device on the electrical junction box.

Installing on a smooth surface with battery supply

  1. Remove the button cover.
  2. Remove the paper strip protecting the battery.
  3. LED ring light means the device is powered.
  4. Insert the button cover back.
  5. Remove the mounting frame from the device.
  6. Use the included double-sided adhesive tape to stick the mounting frame to a smooth and clean surface.
  7. Push the device onto the mounting frame of the device, you should hear an audible click.

 

Installing on a mounting box with battery supply

  1. Remove the mounting frame from the device.
  2. Place the mounting frame onto the mounting box and secure it with screws.
  3. Push the device onto the mounting frame of the device, you should hear an audible click.
  4. Remove the button cover.
  5. Remove the paper strip protecting the battery.
  6. LED ring light means the device is powered.
  7. Insert the button cover back.

 

Installing on a mounting box with an external power supply

Prepare the power supply

  1. Switch off the mains voltage (disable the fuse).
  2. Using wire connectors, connect included power connector to the power supply (black to negative wire, red to positive wire).
  3. Using wire connectors, connect the power supply to the mains.
  4. Place the power supply inside the mounting box, leaving the power connector outside.

Assemble the device

  1. Remove the mounting frame from the device.
  2. Push the power connector through the hole in the mounting frame.
  3. Place the mounting frame onto the mounting box and secure it with screws.
  4. Plug the power connector into the device.
  5. Push the device onto the mounting frame of the device, you should hear an audible click.
  6. Switch on the mains voltage.
  7. LED ring light means the device is powered.
  8. Remove the button cover.
  9. Remove the paper strip protecting the battery if you want to use it as an emergency power source, remove the battery otherwise.
  10. Insert the button cover back.

Product Usage

 Powering modes

External supply mode

In external supply mode, the device indicates commands status and can receive indications from the Z-Wave controller (using Indicator CC), including Identification.
Device configuration is updated immediately.
To enable the external supply mode, make sure that the external supply is connected and powered, then add the device to the Z-Wave network (remove beforehand if already added).

Battery mode

In battery mode, the device indicates commands status, but cannot receive indications from the Z-Wave controller (using Indicator CC), except for Identification.
The device needs to be woken up to change its configuration.
The battery level (in percent) is measured during every power-up and periodically every 24h, the measured value is reported to the controller during every power-up and when it changes by at least 5%.
To enable the battery mode, make sure that the device is powered only using the battery, then add the device to the Z-Wave network (remove beforehand if already added).

Temperature sensor

The device is equipped with a built-in temperature sensor. It measures the ambient temperature and reports it to the controller only when it changes by at least 0.1°C, but not more often than every 10 minutes. It is recommended to use battery or 12V DC power supply for reliable temperature measurement.

Operating modes

Scene Controller

This mode is enabled by default or by setting parameter 20 to 0.

In this mode, the device can activate scenes in the Z-Wave controller by sending scene ID and attribute of a specific action (using Central Scene Command Class). Associations do not work in this mode.

Double Button Mode

This mode is enabled by setting parameter 20 to 1.

In this mode, the device works as two separate buttons and it uses associations to control other Z-Wave devices (groups 2-5). You can control multiple devices of different types in this mode. Every button can control different group of devices.

1st button - controls 2nd and 3rd group:

  • Click - alternately ON with last level / OFF,
  • 2xClick - send pre-set level (set in parameter 152),
  • Hold - alternately increasing/decreasing level until released.

2nd button - controls 4th and 5th group:

  • Click - alternately ON with last level / OFF,
  • 2xClick - send pre-set level (set in parameter 153),
  • Hold - alternately increasing/decreasing level until released.

Single Button Mode

This mode is enabled by setting parameter 20 to 2.

In this mode, the device works as one logical button and it uses associations to control other Z-Wave devices (groups 2-3). You can control multiple devices of different types in this mode.

1st and 2nd button work in the same way:

  • Click - alternately ON with last level / OFF,
  • 2xClick - send pre-set level (set in parameter 152),
  • Hold - alternately increasing/decreasing level until released.

Switch Controller

This mode is enabled by setting parameter 20 to 3.

In this mode, the device uses associations to control Z-Wave binary switches (group 6).

  • Click 1st - ON,
  • Click 2nd - OFF.

Dimmer / Roller Shutter Controller

This mode is enabled by setting parameter 20 to 4.

In this mode, the device uses associations to control Z-Wave dimmers and rollers shutters (group 6).

1st button - turns ON and increases level:

  • Click - ON with the last level,
  • Hold - increasing level until released,
  • 2xClick - send pre-set level (set in parameter 152).

2nd button - turns OFF and decreases level:

  • Click - OFF,
  • Hold - decreasing level until released.

Roller Shutter Step-By-Step Controller

This mode is enabled by setting parameter 20 to 5.

In this mode, the device uses associations to control Z-Wave roller shutter controllers (group 6) in Step-By-Step mode (alternately sends commands for movement and stopping).

1st button - opens and stops:

  • Click - open/stop,
  • 2xClick - send pre-set level (set in parameter 152).

2nd button - closes and stops:

  • Click - close/stop,
  • 2xClick - stop.

Venetian blinds Step-By-Step Controller

This mode is enabled by setting parameter 20 to 6.

In this mode, the device uses associations to control Z-Wave Venetian blinds (with slats) controllers (groups 6-7) in Step-By-Step mode (alternately sends commands for movement and stopping).

1st button - opens and stops:

  • Click - open/stop,
  • 2xClick - send pre-set level (set in parameter 152),
  • Hold - opening slats until released.

2nd button - closes and stops:

  • Click - close/stop,
  • 2xClick - stop,
  • Hold - closing slats until released.

 

Visual indications

The built-in LED light shows current device status.

After powering the device:

  • Green - device added to a Z-Wave network (non-secure, S0, S2 non-authenticated),
  • Magenta - device added to a Z-Wave network (Security S2 Authenticated),
  • Red - device not added to a Z-Wave network.

Update:

  • Blinking cyan - update in progress,
  • Green - update successful,
  • Red - update not successful.

Command status:

The device displays current command status in response to clicking/holding the button.

  • Green for 2 seconds - command acknowledged,
  • Red for 2 seconds - command not acknowledged.

Identification:

The Z-Wave controller can identify this device by signalling with LED ring (using Indicator CC).

Custom indications:

In external supply mode, the user can use the LED ring to display custom indications. Using the Z-Wave controller user can specify on which half of the ring to indicate, number of blinks and timing (using Indicator CC). Brightness and colour of the indications is specified in parameters 13, 150 and 151.


Menu

Menu allows to perform Z-Wave network actions. In order to use the menu:

  1. Quickly, three times click, then press and hold one of the buttons. 
  2. After 3 seconds LED ring signals adding status:
    • Blinking green - entering the menu (added as non-secure, S0, S2 non-authenticated)
    • Blinking magenta  - entering the menu (added as Security S2 Authenticated)
    • Blinking red - entering the menu (not added to a Z-Wave network)
  3. The LED ring will turn off for 3 seconds, then start signalling menu positions.
  4. Release the button when device signals desired position with colour:
    • WHITE - wake up the device
    • GREEN - start learning mode (add/remove)
    • MAGENTA - test Z-Wave range
    • CYAN - show battery level
      • Green - 50-100%
      • Yellow - 16-49%
      • Red - 1-15%
    • YELLOW - reset to factory defaults
  5. Quickly click the button to confirm.

Reset to factory default
  1. Quickly, three times click, then press and hold one of the buttons for 21 seconds.
  2. Release the button when the device glows yellow.
  3. Quickly click the button to confirm.
  4. After a few seconds the device will be restarted, which is signalled with red LED colour.
Inclusion
  1. Set the main controller into the adding mode (see the controller’s manual).
  2. Quickly, three times click one of the buttons.
  3. If you are adding in Security S2 Authenticated, input the underlined part of the DSK (label on the box).
  4. LED will start blinking yellow, wait for the adding process to end.
  5. Adding result will be confirmed by the Z-Wave controller’s message and the LED frame:
    • Green – successful (non-secure, S0, S2 non-authenticated),
    • Magenta – successful (Security S2 Authenticated),
    • Red – not successful.
Exclusion
  1. Set the main controller in remove mode (see the controller‘s manual).
  2. Quickly, three times click, then press and hold one of the buttons for 12 seconds.
  3. Release the button when the device glows green.
  4. Quickly click the button to confirm.
  5. LED will start blinking yellow, wait for the removing process to end.
  6. Successful removal will be confirmed by the Z-Wave controller’s message and red LED colour.
NIF XXXNIF
Wakeup
  1. Quickly, three times click, then press and hold one of the buttons.
  2. Release the button when the device glows white.
  3. Quickly click the button to confirm.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Lifeline
2 5 On/Off (1) is used to turn the associated devices on/off.
3 5 Dimmer (1) is used to change level of associated devices.
4 5 On/Off (2) is used to turn the associated devices on/off.
5 5 Dimmer (2) is used to change level of associated devices.
6 5 Multidevice is used to control different type of devices.
7 5 Slats is used to move slats of Venetian blinds.

Configuration Parameters

Parameter 13: LED framebrightness

This parameter allows to adjust the LED frame brightness.
Size: 1 Byte, Default Value: 100

Setting Description
0 LED disabled
1 - 100 1-100% brightness

Parameter 20: Operation mode

This parameter defines operation of the device. Choose the mode depending on the type of the device you want to control remotely
Size: 1 Byte, Default Value: 0

Setting Description
0 scene controller mode
1 double button mode
2 3-position single button mode
3 switch controller mode
4 dimmer controller mode
5 roller shutter / gate controller mode (step-by-step)
6 venetian blinds controller mode (step-by-step)

Parameter 150: LED ring first button

This parameter defines the colour of first button indicator (upper part of the LED ring) for indications using Indicator CC.
Size: 2 Byte, Default Value: 1

Setting Description
0 LED disabled
1 White
2 Red
3 Green
4 Blue
5 Yellow
6 Cyan
7 Magenta
8 LAPD (blinking red-white-blue)

Parameter 151: LED ring second button

This parameter defines the colour of second button indicator (lower part of the LED ring) for indications using Indicator CC.
Size: 2 Byte, Default Value: 1

Setting Description
1 White
2 Red
3 Green
4 Blue
5 Yellow
6 Cyan
7 Magenta
8 LAPD (blinking red-white-blue)
0 LED disabled

Parameter 152: 1st button - double click value

This parameter defines value of Basic Set or Multilevel Set frame (depending on selected mode) sent to associated devices after double click. This parameter is not relevant for Scene Controller Mode.
Size: 2 Byte, Default Value: 99

Setting Description
0 - 99 value of Basic Set
255 Multilevel Set frame

Parameter 153: 2nd button - double click value

This parameter defines value of Basic Set or Multilevel Set frame (depending on selected mode) sent to associated devices after double click. This parameter is not relevant for Scene Controller Mode.
Size: 2 Byte, Default Value: 99

Setting Description
0 - 99 value of Basic Set
255 Multilevel Set frame

Technical Data

Dimensions 86 x 86 x 20 mm mm
Weight 51 gr
Hardware Platform ZGM130
EAN 5902701702076
IP Class IP 20
Voltage 5-24V DC
Battery Type 1 * ER14250
Device Type Central Scene Device
Network Operation Always On Slave
Certification ID ZC12-20060078
Z-Wave Product Id 0x010F.0x2301.0x1000
Color White
Firmware Updatable Updatable by Consumer by RF
Z-Wave Scene Type Central Scene
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeCentral Scene Device