Heatit Z-Temp2 is a battery-operated thermostat designed for usewith water based heating systems. Used in combination with theHeatit Z-Water regulator you can control your heating system with aZ-Wave primary controller/gateway with the use of Heatit Z-Water incombination with one or several Heatit Z-Temp2.
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Lifeline. Normally used by the Z-WaveController. |
2 | 5 | Multilevel Sensor Report (internal measured temperate and measured relative humidity). |
3 | 5 | Binary Switch Set (normally used to control external relays). |
Used to adjust the time between report interval for Temperature and humidity reports. Size: 2 Byte, Default Value: 900
Setting | Description |
---|---|
30 - 32767 | 30 to 32 767 seconds (Default 900) |
Adjust the delta values for the thermostat to turn on off heating. Size: 2 Byte, Default Value: 5
Setting | Description |
---|---|
3 - 30 | 0.3 to 3C (Default 5, 0,5C) |
Set the minimum temperature limit. Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
50 - 400 | 5 to 40C (Default 50, 5C) |
Set the maximum temperature limit. Size: 2 Byte, Default Value: 400
Setting | Description |
---|---|
50 - 400 | 5 to 40C (Default 400, 40C) |
Set time on how often the devices sends Binary Switch Set and thermostat mode to gateway. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Sends only when changed (Default) |
1 - 240 | 1 to 240 minutes + When changed |
Decides if the thermostat sends temperature when presence is detected. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Do not report to gateway when presence is detected, only at interval. (Default) |
1 | Send temperature report to gateway when presence is detected. |
Temperature delta value. Size: 2 Byte, Default Value: 10
Setting | Description |
---|---|
0 | Reporting temperate based on change is disabled |
5 - 50 | 0.5 to 5C (Default 10, 1.0C) |
Humidity delta value. Size: 2 Byte, Default Value: 10
Setting | Description |
---|---|
0 | Reporting temperate based on change is disabled |
5 - 50 | 5 to 50% (Default 10, 10%) |
Calibrate the internal sensor. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
-100 - 100 | -100 to 100C (Default 0, 0C) |
Offsets the measured relative humidity. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
-100 - 100 | -10 to 10% (Default 0, 0%) |
Proximity sensor retrigger interval. Size: 2 Byte, Default Value: 10
Setting | Description |
---|---|
2 - 270 | 2 to 270 seconds (Default 10, 10 seconds) |
Choose if proximity sensor is used or not. Size: 2 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable |
1 | Enable (Default) |
Adjust the backlight of LCD display. Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
0 - 99 | 0 to 99% (Default 50, 50%) |
Adjust the time from proximity sensor / display touched until display goes to sleep. Size: 2 Byte, Default Value: 3
Setting | Description |
---|---|
3 - 300 | 3 to 300 secounds (Default 3, 3 seconds). |
Hardware Platform | EFR32Z |
Device Type | Thermostat - HVAC |
Network Operation | Listening Sleeping Slave |
Firmware Version | HW: 1 FW: 1.01:00.02 |
Z-Wave Version | 7.11.1 |
Certification ID | ZC12-20050065 |
Z-Wave Product Id | 0x019B.0x0004.0x0204 |
Thermostat HVAC Systems Supported | Dual FuelHumidity ControlUniversal |
Thermostat Modes | Heat |
Color | White |
Thermostat Power Source | Battery |
Firmware Updatable | Updatable by Manufacturer |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |