This is a
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Aeotec Smart Switch 7 is a Z-Wave Switch plug-in module specifically used to enable Z-Wave command and control (on/off) of any plug-in tool. It can report immediate wattage consumption or kWh energy usage over a period of time. In the event of power failure, non-volatile memory retains all programmed information relating to the units operating status.The Plug is also a security S2 Z-Wave device, it supports Over The Air (OTA) feature for the products firmware upgrade and SmartStart network pairing feature.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | This is the lifeline group.Device Reset Locally:When factory reset.Notification Report (Type=0x08, Event=0x08):When over load detected.Basic Report:When switch state changed. See parameter 42for more information.Switch Binary Report:When switch state changed. See parameter 42for more information.Switch Multilevel Report:Issued when multilevel switch value of theindicator light has changed.Switch Color Report:Issued when a color component level of theindicator has changed.Meter Report:Issued periodically according to the parameter23,24,25,26 or above the threshold.Clock Report:Issued per hour.Indicator Report:Issued when the indicator light changed. |
2 | 5 | Mirror of endpoint 1. |
3 | 5 | Trigger to send Scene Activation Set to this group when the load wattage above the parameter 6's setting. |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
This parameter is used to change the reaction of LED setting.0 - Disable LED completely. LED will only be used for network operation indicator, such as inclusion, exclusion, factory reset. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | Disable LED completely |
1 - 0 | Turn on between particular times only (act as night light). |
2 - 0 | Display On/Off Status. |
Turn off switch when current of load connected bypasses the maximum allowed power regardless of always on setting. Unit W.0 - disable overload protection 1~1800 - When watt detected above this setting value, the switch will be turned off immediately. And an over-load notification will be sent. Size: 2 Byte, Default Value: 1800
Setting | Description |
---|---|
0 | disable overload protection |
1 - 1800 | When watt detected above this setting value, the switch will be turned off immediately. And an over-load notification will be sent. |
This parameter is used to set the over-voltage protect value, unit V.0 - disable over-voltage protection 95~255 - When voltage detected above this setting value, the switch will be turned off immediately. And an over-voltage notification will be sent. Size: 1 Byte, Default Value: 135
Setting | Description |
---|---|
0 | disable over-voltage protection |
1 - 255 | When voltage detected above this setting value, the switch will be turned off immediately. And an over-voltage notification will be sent. |
Set the period of threshold check. Unit second.0 - disable all threshold settings 1~255 - set in seconds on how fast device checks for threshold settings Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 | disable all threshold settings |
1 - 255 | set in seconds on how fast device checks for threshold settings |
This parameter is used to configure the Night Light on time. User can use Color CC to change the Night Light color(default Red). Only useful when parameter 1 is set to 1.RR = ReservedHH = HoursMM = MinutesSS = SecondsDefault = 0x00180000 means 6pm Size: 4 Byte, Default Value: 1572864
Setting | Description |
---|---|
0 - 2316633 | This parameter is used to configure the Night Light on time.RR = Reserved HH = Hours MM = Minutes SS = Seconds Default = 0x00180000 means 6pm |
Energy kWh threshold reporting enable/disable. Unit kWh. Size: 2 Byte, Default Value: 100
Setting | Description |
---|---|
0 | Disable kWh threshold reporting |
1 - 10000 | kWh threshold setting. |
Threshold setting for Watt for inducing automatic report.Unit W. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable Watt threshold reporting |
1 - 2500 | Watt threshold setting. |
Threshold settings for current for inducing automatic report. Unit A Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable Watt threshold reporting |
1 - 150 | Current threshold setting. |
Set the automatic report time of Watt. Unit second. Size: 2 Byte, Default Value: 600
Setting | Description |
---|---|
0 - 65535 | Set the automatic report time of Watt |
Set the automatic report time of kWh. Unit second. Size: 2 Byte, Default Value: 600
Setting | Description |
---|---|
0 - 65535 | Set the automatic report time of kWh. Unit second. |
Set the automatic report time of Voltage. Unit second. Size: 2 Byte, Default Value: 600
Setting | Description |
---|---|
0 - 65535 | Set the automatic report time of Voltage. Unit second. |
Restore the product to factory settings and remove from the network.0x55555555 - Restore the product to factory settings and remove from the network. Other - Initialize all configuration parameters to default values. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Initialize all configuration parameters to default values. |
4294967295 | Restore the product to factory settings and remove from the network |
Set the automatic report time of Current. Unit second. Size: 2 Byte, Default Value: 600
Setting | Description |
---|---|
0 - 65535 | Set the automatic report time of Current. Unit second. |
This parameter is used to configure the Night Light off time. Only useful when parameter 1 is set to 1.RR = ReservedHH = HoursMM = MinutesSS = SecondsDefault = 0x00060000 means 6am Size: 4 Byte, Default Value: 393216
Setting | Description |
---|---|
0 - 2316633 | This parameter is used to configure the Night Light off time. Only useful when parameter 1 is set to 1. RR = Reserved HH = Hours MM = Minutes SS = Seconds Default = 0x00060000 means 6am |
Determines if alarms are enabled in Switch, and what Switch will react to which alarms. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 - 0 | Smoke Alarm |
2 - 0 | CO Alarm |
4 - 0 | CO2 Alarm |
8 - 0 | Heat Alarm |
16 - 0 | Water Alarm |
32 - 0 | Access Control |
64 - 0 | Home Security |
128 - 0 | Motion Sensor trigger |
0 | Disable alarm |
Enabled by Alarm Settings, and determines what the switch does in the case an alarm is triggered.0 - disable , no reaction to alarm settings 1 - Switch is ON 2 - Switch is OFF 3~255 - Sets rate at which Switch turns ON and OFF in seconds. (i.e. If set to 3, then Switch will turn ON in 0.3 seconds, and then turn OFF in 0.3 seconds in a cycle until user disables the alarm manually. If set to 255, then it will cycle every 25.5 seconds) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | disable , no reaction to alarm settings |
1 | Switch is ON |
2 | Switch is OF |
3 - 255 | Sets rate at which Switch turns ON and OFF in seconds. |
Determines the method of disabling the alarm of the device.0 - Can be disabled by 1 tapping Switches action button once. 1 - Can be disabled by 2 tapping Switches action button within 1 second. 2 - Can be disabled by 4 tapping Switches action button within 2 seconds. 4 - Can be disabled by pressing and holding Switches action button about 4 seconds. 5~255 - Sets the duration of the alarm in seconds (i.e Sets this setting to 50, the alarm state of the switch will disable after 50 seconds) Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Can be disabled by 1 tapping Switches action button once. |
1 | Can be disabled by 2 tapping Switches action button within 1 second. |
2 | Can be disabled by 4 tapping Switches action button within 2 seconds. |
4 | Can be disabled by pressing and holding Switches action button about 4 seconds. |
5 - 255 | Sets the duration of the alarm in seconds (i.e Sets this setting to 50, the alarm state of the switch will disable after 50 seconds) |
Set the duration of blink, unit second.0 - indicates that it is not blinking1~255 - set the duration Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Indicates that it is not blinking |
1 - 255 | Set the duration |
Acts as auto off after as soon as the switch turns ON, setting is set in seconds.0 - no auto off with timer 1~86400 - seconds Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | no auto off with timer |
1 - 86400 | seconds |
Acts as auto on after as soon as the switch turns OFF, setting is set in seconds.0 - no auto on with timer 1~86400 - seconds Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | no auto on with timer |
1 - 86400 | Seconds |
Which report will be sent to lifeline group when the output state is changed.0 - Send nothing 1 - Send Basic Report 2 - Send Switch Binary Report Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | Send nothing |
1 - 0 | Send Basic Report |
2 - 0 | Send Switch Binary Report |
Set amount of blinks per second.i.e. If set to 5, it should blink 5 times per second. Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
1 - 24 | Set amount of blinks per second. |
Send alert when in use. A Scene Activation Set command will be sent when energy draw is above this setting value.0 - disable1~3000 - enable, unit W Size: 2 Byte, Default Value: 100
Setting | Description |
---|---|
0 | Disable |
1 - 3000 | Enable |
Prevents the plug from being turned off via its button.0 - the plug will operate as normal and can be turned on or off. 1 - the button on the plug will be disabled for on and off commands, but still work for network inclusion and exclusion. 2 - the plug will ignore any commands to turn it off and it will ignore any use of the button (but still work for network inclusion and exclusion) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | the plug will operate as normal and can be turned on or off. |
1 - 0 | the button on the plug will be disabled for on and off commands, but still work for network inclusion and exclusion. |
2 - 0 | the plug will ignore any commands to turn it off and it will ignore any use of the button (but still work for network inclusion and exclusion) |
Set the plugs action in case of power out.0 - last status1 - power on2 - power off Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Last status |
1 | Power On |
2 | Power Off |
Set the scene id when Scene Activation Set Command sent through group3. Refer parameter 6 for more information. Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
1 - 255 | Set the scene id when Scene Activation Set Command sent through group3. |
Hardware Platform | ZGM130 |
Device Type | Binary Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.02 |
Z-Wave Version | 7.12.2 |
Certification ID | ZC12-20050064 |
Z-Wave Product Id | 0x0371.0x0103.0x0017 |
Security V2 | S2_UNAUTHENTICATED ,S2_AUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |