Quickstart

This is a secure Lock for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

HAVEN is a first-of-its-kind preventative home security product. Our floor-anchored, electronic locking wedge fortifies the door at its strongest pointthe base.Made with steel, Delrin, and military grade nylon, the HAVEN system is 10x stronger than your deadbolt.Technical Details: - Installs in minutes - Operated electronically or manually with a foot pedal - Composition: Steel, Delrin, and military grade nylon - Connection: Z-Wave (700-Series) with S2 Security- Strength: 10x stronger than your deadbolt, Haven provides an additional layer of protection in an effort to deter a break-in at the door - Main Battery: Rechargeable 3.7V 5000MAH Lipo battery

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Lifeline Group 1 for processing unsolicited notifications.

Configuration Parameters

Parameter 1: Heartbeat LED interval

Heartbeat (magenta) LED flash rate in seconds. Set to zero to disable.
Size: 1 Byte, Default Value: 30

Setting Description
0 - 60 LED flash rate in seconds. Example: 30 = LED flash interval of 30 seconds.

Parameter 2: Gate Operation Minimum Battery Level %

Minimum battery level at which the gate will activate.
Size: 1 Byte, Default Value: 10

Setting Description
0 - 50 The percent battery level in which the system enters u0022Critical Low Batteryu0022 mode. Example: 10 means 10% is critical low battery

Parameter 3: Impact Detection Parameter 1

Impact detect parameter. Do not adjust unless advised by Haven Lock.
Size: 1 Byte, Default Value: 2

Setting Description
1 - 10 Represents u0022tensu0022 of milliseconds to debounce the impact detection system. Example: 2 means 20ms debounce

Parameter 4: Impact Detection Parameter 2

Impact detect parameter. Do not adjust unless advised by Haven Lock.
Size: 1 Byte, Default Value: 8

Setting Description
2 - 18 From accelerometer data sheet regarding impact transient detection, you can set the threshold with values that represent a light movement to a strong acceleration transient. Example: 8 represents an impact detection equivalent to moderate forced intrusion.

Technical Data

Hardware Platform ZGM130
Device Type Lock
Network Operation Listening Sleeping Slave
Firmware Version HW: 1 FW: 0.51
Z-Wave Version 7.12.2
Certification ID ZC12-20050062
Z-Wave Product Id 0x043A.0x0004.0x0001
Firmware Updatable Updatable by Manufacturer
Frequency XXfrequency
Maximum transmission power XXantenna