This is a
HAVEN is a first-of-its-kind preventative home security product. Our floor-anchored, electronic locking wedge fortifies the door at its strongest pointthe base.Made with steel, Delrin, and military grade nylon, the HAVEN system is 10x stronger than your deadbolt.Technical Details: - Installs in minutes - Operated electronically or manually with a foot pedal - Composition: Steel, Delrin, and military grade nylon - Connection: Z-Wave (700-Series) with S2 Security- Strength: 10x stronger than your deadbolt, Haven provides an additional layer of protection in an effort to deter a break-in at the door - Main Battery: Rechargeable 3.7V 5000MAH Lipo battery
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Lifeline Group 1 for processing unsolicited notifications. |
Heartbeat (magenta) LED flash rate in seconds. Set to zero to disable. Size: 1 Byte, Default Value: 30
Setting | Description |
---|---|
0 - 60 | LED flash rate in seconds. Example: 30 = LED flash interval of 30 seconds. |
Minimum battery level at which the gate will activate. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 - 50 | The percent battery level in which the system enters u0022Critical Low Batteryu0022 mode. Example: 10 means 10% is critical low battery |
Impact detect parameter. Do not adjust unless advised by Haven Lock. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
1 - 10 | Represents u0022tensu0022 of milliseconds to debounce the impact detection system. Example: 2 means 20ms debounce |
Impact detect parameter. Do not adjust unless advised by Haven Lock. Size: 1 Byte, Default Value: 8
Setting | Description |
---|---|
2 - 18 | From accelerometer data sheet regarding impact transient detection, you can set the threshold with values that represent a light movement to a strong acceleration transient. Example: 8 represents an impact detection equivalent to moderate forced intrusion. |
Hardware Platform | ZGM130 |
Device Type | Lock |
Network Operation | Listening Sleeping Slave |
Firmware Version | HW: 1 FW: 0.51 |
Z-Wave Version | 7.12.2 |
Certification ID | ZC12-20050062 |
Z-Wave Product Id | 0x043A.0x0004.0x0001 |
Firmware Updatable | Updatable by Manufacturer |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |