Quickstart

This is a secure Door Lock - Keypad for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

Expanding the Yale nexTouch product line for even more applications, the new nexTouch Sectional Mortise Keypad Lock provides robust security for a wide range of commercial and multi-family buildings. Just like the original cylindrical nexTouch lock, it is ANSI/BHMA Grade 1 certified and offered in capacitive touchscreen or pushbutton keypad versions. With just the addition of a Z-Wave Plus module, you can add this lock to compatible smart home and alarm systems. Other standard features include voice-guided programming, privacy mode with Door Position Switch, 9V battery backup, support of up to 100 unique user codes, and more.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus Lifeline

Configuration Parameters

Parameter 1: Silent Mode on/off

Level control, 1 = High Volume, 2 = Low Volume, 3 = Silent. Default is 1 or High Volume
Size: 1 Byte, Default Value: 1

Setting Description
1 - 3 Level

Parameter 11: One Touch Locking

0x00 = OFF, 0xFF = ON default is 0xFF or ON.
Size: 1 Byte, Default Value: 255

Setting Description
0 One Touch Locking Off
255 One Touch Locking On

Parameter 12: Privacy Button

0x00 = OFF, 0xFF = ON default is 0x00 or OFF
Size: 1 Byte, Default Value: 0

Setting Description
0 Privacy Button Off
255 Privacy Button On

Parameter 15: Reset to Factory Defaults

01 = Lock will execute Reset To Factory.No default value
Size: 1 Byte, Default Value: 0

Setting Description
0 Reset to Factory Off
1 Reset to Factory On

Parameter 16: Escape Return Mode

0x00 = OFF, 0xFF = ON default is 0x00 or OFFEnables the Escape Return mode of operation for thelock.
Size: 1 Byte, Default Value: 0

Setting Description
0 Escape Return Mode Off
127 Escape Return Mode On

Parameter 18: Door Propped Timer

10 to 2540 second. This value is represented asseconds X 10. (ie a value of 4 would mean a doorpropped timer of 40 seconds) Set to 0x00 to disableDoor Propped Alarm. Default = 0x00 (OFF)
Size: 1 Byte, Default Value: 0

Setting Description
0 - 255 Seconds

Parameter 19: DPS Alarm

0x00 = OFF, 0xFF = ON Default is 0xFF or ON.Used to enable/disable door condition alarms for locksthat support a door position sensor. Any lock that doesnot support DPS will always report 0x00.
Size: 1 Byte, Default Value: 0

Setting Description
0 DPS Alarm Off
255 DPS Alarm On

Parameter 2: Auto Relock On/Off

0x00 = OFF, 0xFF = ON default is 0x00 or OFF
Size: 1 Byte, Default Value: 0

Setting Description
0 Auto Relock Off
255 Auto Relock On

Parameter 20: Deadbolt Installed

0x00 = NO deadbolt , 0xFF = YES deadbolt
Size: 1 Byte, Default Value: 0

Setting Description
0 Deadbolt No
255 Deadbolt Yes

Parameter 21: Eco Mode On/Off

0x00 = OFF, 0xFF = ON default is 0x00 or OFFIf supported switches lock to lower power mode ofoperation with reduced sound and led brightness.
Size: 1 Byte, Default Value: 0

Setting Description
0 Eco Mode Off
255 Eco Mode On

Parameter 22: Privacy Mode with Deadbolt

0x00 = OFF, 0xFF = ON default is 0x00 or OFFIf enabled then extending the deadbolt will put the lockinto Privacy Mode.
Size: 1 Byte, Default Value: 0

Setting Description
0 Privacy Mode Off
255 Privacy Mode On

Parameter 23: Lock Body Alarms Mask

Each bit controls one alarm. 1 = alarm enabled, 0 =alarm disabled.0xFF = All Alarms on, Default is 0xFF.Bit 0: DPS Alarm (AX) (Duplicate of parameter 19.Values should be tied together)Bit 1: Deadbolt AlarmBit 2: Lever Rotated (Rx)Bit 37: Not Used
Size: 1 Byte, Default Value: 255

Setting Description
0 No Sensor Alarm
255 All Sensors Alarm

Parameter 3: Auto Relock Time

1 to 180 seconds default is 3 seconds
Size: 1 Byte, Default Value: 3

Setting Description
3 - 180 Seconds

Parameter 4: Wrong Code Entry Limit

3 to 10 default is 5 times
Size: 1 Byte, Default Value: 5

Setting Description
3 - 10 Times

Parameter 5: Language

Set the lock language. Default is 1= English
Size: 1 Byte, Default Value: 1

Setting Description
1 English Language
2 Spanish Language
3 French Language

Parameter 7: Shut Down Time (after wrong code entries)

10 to 127 seconds default is 60 seconds
Size: 1 Byte, Default Value: 60

Setting Description
10 - 127 Seconds

Parameter 8: Operating Mode

This sets the operating mode for the lock.
Size: 1 Byte, Default Value: 0

Setting Description
0 Normal Mode (Default)
1 Vacation Mode (Keypad Locked Out)
2 Privacy Mode (Keypad Locked, RF Unlock Functional)
3 passage mode, Lock is permanently unlocked.

Technical Data

Hardware Platform ZM5101
Device Type Door Lock - Keypad
Network Operation Listening Sleeping Slave
Firmware Version HW: 255 FW: 1.78:32.27
Z-Wave Version 6.51.07
Certification ID ZC10-22067095
Z-Wave Product Id 0x0129.0x8100.0x0A0C
IP (Ingress Protection) Rated ok
Outdoor Use ok
Supported Notification Types
Firmware Updatable
Door Lock Type
Frequency XXfrequency
Maximum transmission power XXantenna
Door Lock - Keypad