This is a secure On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The MP31ZP is a mini plug-in outlet equipped with Z-Wavecapabilities and energy monitoring for additional convenience. This smart plug allows you to plug in and access an appliance through the certified Z-Wave hubs.Schedule your appliances, run a timer, or check the On/Off status to monitor and save energy.The compact size gives full access to the second outlet in a standard receptacle.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Z-Wave Lifeline
2 5 Basic Set Command
3 5 basic set command

Configuration Parameters

Parameter 1: Restores state after power failure

Restores state after power failure
Size: 1 Byte, Default Value: 0

Setting Description
0 The state before a power outage.
1 outlet on
2 outlet off

Parameter 10: Endpoint1 Enable Auto Turn-ON Timer

Endpoint1 Enable Auto Turn-ON Timer
Size: 1 Byte, Default Value: 0

Setting Description
0 Auto Turn-ON Timer Disabled
1 Auto Turn-ON Timer Enabled

Parameter 11: Endpoint1 Count Down Configuration(Turn on the output by time

Endpoint1 Count Down Configuration(Turn on the output by time
Size: 4 Byte, Default Value: 60

Setting Description
1 - 65535 Endpoint1 Count Down Configuration(Turn on the output by time

Parameter 12: Endpoint2 Enable Auto Turn-OFF Timer

Endpoint2 Enable Auto Turn-OFF Timer
Size: 1 Byte, Default Value: 0

Setting Description
0 Auto Turn-OFF Timer Disabled
1 Auto Turn-OFF Timer Enabled

Parameter 13: Endpoint2 Count Down Configuration(Turn off the output by time

Endpoint2 Count Down Configuration(Turn off the output by time
Size: 4 Byte, Default Value: 60

Setting Description
1 - 65535 Endpoint2 Count Down Configuration(Turn off the output by time

Parameter 14: Parameter Endpoint2 Enable Auto Turn-ON Timer

Endpoint2 Enable Auto Turn-ON Timer
Size: 1 Byte, Default Value: 0

Setting Description
0 Auto Turn-ON Timer Disabled
1 Auto Turn-ON Timer Enabled

Parameter 15: Endpoint2 Count Down Configuration(Turn on the output by time

Endpoint2 Count Down Configuration(Turn on the output by time
Size: 4 Byte, Default Value: 60

Setting Description
1 - 65535 Endpoint2 Count Down Configuration(Turn on the output by time

Parameter 16: Manual Control

Manual Control
Size: 1 Byte, Default Value: 1

Setting Description
0 Manual Control Disabled
1 manual control enabled

Parameter 17: Status LED Configuration

Status LED Configuration
Size: 1 Byte, Default Value: 1

Setting Description
0 LED indicator will display power consumption whenever the device is plugged in
1 LED indicator will display power consumption whenever the device is ON in and will turn off when the plug is OFF
2 LED indicator will display the level of power consumption for 5 seconds only whenever the device is turned on or off
3 Always OFF

Parameter 2: Power Wattage Report Value Threshold(Wattage)

Power Wattage Report Value Threshold(Wattage)
Size: 4 Byte, Default Value: 10

Setting Description
0 - 65535 Power Wattage Report Value Threshold(Wattage)

Parameter 3: Power Wattage Report Frequency (Timer)

Power Wattage Report Frequency (Timer)
Size: 4 Byte, Default Value: 30

Setting Description
0 - 2678400 Power Wattage Report Frequency (Timer)

Parameter 4: Energy (kWh) Report Frequency (Timer)

Energy (kWh) Report Frequency (Timer)
Size: 4 Byte, Default Value: 300

Setting Description
30 - 2678400 Energy (kWh) Report Frequency (Timer)

Parameter 5: Parameter Voltage (V) Report Frequency (Timer)

Voltage (V) Report Frequency (Timer)
Size: 4 Byte, Default Value: 300

Setting Description
30 - 2678400 Voltage (V) Report Frequency (Timer)

Parameter 6: Electricity (A) Report Frequency (Timer)

Electricity (A) Report Frequency (Timer)
Size: 4 Byte, Default Value: 300

Setting Description
30 - 2678400 Electricity (A) Report Frequency (Timer)

Parameter 7: Overload Protection (Current)

Overload Protection (Current)
Size: 1 Byte, Default Value: 13

Setting Description
1 - 16 Overload Protection (Current)

Parameter 8: Endpoint1 Enable Auto Turn-OFF Timer

Endpoint1 Enable Auto Turn-OFF Timer
Size: 1 Byte, Default Value: 0

Setting Description
0 Auto Turn-OFF Timer Disabled
1 Auto Turn-OFF Timer Enabled

Parameter 9: Endpoint1 Count Down Configuration(Turn off the output by time

Endpoint1 Count Down Configuration(Turn off the output by time
Size: 4 Byte, Default Value: 60

Setting Description
1 - 65535 Endpoint1 Count Down Configuration(Turn off the output by time

Technical Data

Hardware Platform ZM5202
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 255 FW: 1.00
Z-Wave Version 6.71.03
Certification ID ZC10-22057087
Z-Wave Product Id 0x0312.0xFF00.0xFF0E
Firmware Updatable Updatable by Consumer by RF
Color White
Frequency XXfrequency
Maximum transmission power XXantenna
On/Off Power Switch