This is a
The MP31ZP is a mini plug-in outlet equipped with Z-Wavecapabilities and energy monitoring for additional convenience. This smart plug allows you to plug in and access an appliance through the certified Z-Wave hubs.Schedule your appliances, run a timer, or check the On/Off status to monitor and save energy.The compact size gives full access to the second outlet in a standard receptacle.
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Z-Wave Lifeline |
2 | 5 | Basic Set Command |
3 | 5 | basic set command |
Restores state after power failure Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | The state before a power outage. |
1 | outlet on |
2 | outlet off |
Endpoint1 Enable Auto Turn-ON Timer Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Auto Turn-ON Timer Disabled |
1 | Auto Turn-ON Timer Enabled |
Endpoint1 Count Down Configuration(Turn on the output by time Size: 4 Byte, Default Value: 60
Setting | Description |
---|---|
1 - 65535 | Endpoint1 Count Down Configuration(Turn on the output by time |
Endpoint2 Enable Auto Turn-OFF Timer Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Auto Turn-OFF Timer Disabled |
1 | Auto Turn-OFF Timer Enabled |
Endpoint2 Count Down Configuration(Turn off the output by time Size: 4 Byte, Default Value: 60
Setting | Description |
---|---|
1 - 65535 | Endpoint2 Count Down Configuration(Turn off the output by time |
Endpoint2 Enable Auto Turn-ON Timer Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Auto Turn-ON Timer Disabled |
1 | Auto Turn-ON Timer Enabled |
Endpoint2 Count Down Configuration(Turn on the output by time Size: 4 Byte, Default Value: 60
Setting | Description |
---|---|
1 - 65535 | Endpoint2 Count Down Configuration(Turn on the output by time |
Manual Control Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Manual Control Disabled |
1 | manual control enabled |
Status LED Configuration Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | LED indicator will display power consumption whenever the device is plugged in |
1 | LED indicator will display power consumption whenever the device is ON in and will turn off when the plug is OFF |
2 | LED indicator will display the level of power consumption for 5 seconds only whenever the device is turned on or off |
3 | Always OFF |
Power Wattage Report Value Threshold(Wattage) Size: 4 Byte, Default Value: 10
Setting | Description |
---|---|
0 - 65535 | Power Wattage Report Value Threshold(Wattage) |
Power Wattage Report Frequency (Timer) Size: 4 Byte, Default Value: 30
Setting | Description |
---|---|
0 - 2678400 | Power Wattage Report Frequency (Timer) |
Energy (kWh) Report Frequency (Timer) Size: 4 Byte, Default Value: 300
Setting | Description |
---|---|
30 - 2678400 | Energy (kWh) Report Frequency (Timer) |
Voltage (V) Report Frequency (Timer) Size: 4 Byte, Default Value: 300
Setting | Description |
---|---|
30 - 2678400 | Voltage (V) Report Frequency (Timer) |
Electricity (A) Report Frequency (Timer) Size: 4 Byte, Default Value: 300
Setting | Description |
---|---|
30 - 2678400 | Electricity (A) Report Frequency (Timer) |
Overload Protection (Current) Size: 1 Byte, Default Value: 13
Setting | Description |
---|---|
1 - 16 | Overload Protection (Current) |
Endpoint1 Enable Auto Turn-OFF Timer Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Auto Turn-OFF Timer Disabled |
1 | Auto Turn-OFF Timer Enabled |
Endpoint1 Count Down Configuration(Turn off the output by time Size: 4 Byte, Default Value: 60
Setting | Description |
---|---|
1 - 65535 | Endpoint1 Count Down Configuration(Turn off the output by time |
Hardware Platform | ZM5202 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 255 FW: 1.00 |
Z-Wave Version | 6.71.03 |
Certification ID | ZC10-22057087 |
Z-Wave Product Id | 0x0312.0xFF00.0xFF0E |
Firmware Updatable | Updatable by Consumer by RF |
Color | White |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |