This is a
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Push-Control is a compact, battery-powered, Z-Wave Plus compatible device. It allows you to control devices through the Z-Wave network and run various scenes defined in Yubii smart home system.Different actions may be triggered with one to five clicks or by holding the button down. In panic mode, each press of the button results in triggering the alarm defined in the Z-Wave controller.Due to its small design and wireless communication, Push-Control can be conveniently mounted on any surface and in any position or location at home, e.g. beside the bed or under the desk.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | u0022Lifelineu0022 reports the device status and allows for assigning single device only (main controller by default). |
2 | 5 | On/Off is assigned to clicking the button and is used to turn on/off associated devices. |
3 | 5 | Dimmer is assigned to holding the button and is used to change level of associated devices. |
4 | 5 | Alarm is assigned to clicking and/or holding the button (triggers are defined in parameter 30) and is used to send alarm frames to associated devices. |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
This parameter determines which actions result in sending scene IDs and attributes assigned to them.Values of parameter 1 may be combined, e.g. 1+2=3 means that scenes will be sent after pressing the button once or twice. Size: 1 Byte, Default Value: 127
Setting | Description |
---|---|
0 | No scenes sent |
1 | Key Pressed 1 time |
2 | Key Pressed 2 times |
4 | Key Pressed 3 times |
8 | Key Pressed 4 times |
16 | Key Pressed 5 times |
32 | Key Held Down |
64 | Key Released |
127 | All scenes sent |
This parameter defines commands sent to devices associated in 2nd association group after a single click. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
0 | no action |
1 | SWITCH ON |
2 | SWITCH OFF |
3 | SWITCH ON/OFFalternately |
This parameter defines value of SWITCH ON command sent to devices in 2nd association group after a single click. Size: 2 Byte, Default Value: 255
Setting | Description |
---|---|
1 - 255 | sent value |
This parameter defines commands sent to devices associated in 2nd association group after a double click. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | no action |
1 | SWITCH ON |
2 | SWITCH OFF |
3 | SWITCH ON/OFFalternately |
This parameter defines value of SWITCH ON command sent to devices in 2nd association group after a double click. Size: 2 Byte, Default Value: 99
Setting | Description |
---|---|
1 - 255 | sent value |
This parameter defines commands sent to devices associated in 2nd association group after a triple click. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | no action |
1 | SWITCH ON |
2 | SWITCH OFF |
3 | SWITCH ON/OFFalternately |
This parameter defines value of SWITCH ON command sent to devices in 2nd association group after a triple click. Size: 2 Byte, Default Value: 255
Setting | Description |
---|---|
1 - 255 | sent value |
This parameter defines commands sent to devices associated in 3rd association group after a single click. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
0 | no action |
1 | SWITCH ON |
2 | SWITCH OFF |
3 | SWITCH ON/OFFalternately |
This parameter defines value of SWITCH ON command sent to devices in 3rd association group after a single click. Size: 2 Byte, Default Value: 255
Setting | Description |
---|---|
1 - 255 | sent value |
This parameter defines commands sent to devices associated in 3rd association group after a double click. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | no action |
1 | SWITCH ON |
2 | SWITCH OFF |
3 | SWITCH ON/OFFalternately |
This parameter defines value of SWITCH ON command sent to devices in 3rd association group after a double click. Size: 2 Byte, Default Value: 99
Setting | Description |
---|---|
1 - 255 | sent value |
This parameter defines commands sent to devices associated in 3rd association group after a triple click. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | no action |
1 | SWITCH ON |
2 | SWITCH OFF |
3 | SWITCH ON/OFFalternately |
This parameter defines value of SWITCH ON command sent to devices in 3rd association group after a triple click. Size: 2 Byte, Default Value: 255
Setting | Description |
---|---|
1 - 255 | sent value |
This parameter defines commands sent to devices associated in 3rd association group after holding the button down. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
0 | no action |
1 | START LEVEL CHANGE UP (brightening) |
2 | START LEVEL CHANGE DOWN (dimming) |
3 | START LEVEL CHANGE UP/DOWN (brightening/ dimming)alternately |
This parameter defines how commands are sent in specified association groups: as secure or non-secure. Parameter is active only in Z-Wave network Security Mode. It does not apply to 1st Lifeline group.Values of parameter 3 may be combined, e.g. 1+2=3 means that 2nd & 3rd group are sent as secure. Size: 1 Byte, Default Value: 7
Setting | Description |
---|---|
0 | none of the groups sent as secure |
1 | 2nd group sent as secure |
2 | 3rd group sent as secure |
4 | 4th group sent as secure |
7 | all groups sent as secure |
Parameter determines which actions result in sending alarm frames to 4th association group.Values of parameter 30 may be combined, e.g. 1+2=3 means that alarm frames will be sentafter pressing the button once or twice. Size: 1 Byte, Default Value: 127
Setting | Description |
---|---|
0 | No alarms sent |
1 | Key Pressed 1 time |
2 | Key Pressed 2 time |
4 | Key Pressed 3 time |
8 | Key Pressed 4 time |
16 | Key Pressed 5 time |
32 | Key Held Down |
64 | Key Released |
127 | All actions |
Hardware Platform | ZM5101 |
Device Type | Wall Controller |
Network Operation | Portable Slave |
Firmware Version | HW: 1 FW: 3.02 |
Z-Wave Version | 6.51.09 |
Certification ID | ZC10-22047085 |
Z-Wave Product Id | 0x010F.0x0F01.0x1000 |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |