On/Off-Control is designed to be installed in standard wall switch boxes or anywhere else where it is necessary to control electric devices.On/Off-Control allows to control connected devices either via the Z-Wave Plus network or via a switch connected directly to it and is equipped with active power and energy consumption metering functionality
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | u0022Lifelineu0022 reports the device status and allows for assigning single device only (main controller by default). |
2 | 5 | On/Off (S1) is assigned to S1 input terminal (uses Basic command class). |
3 | 5 | u0022Dimmer (S1)u0022 is assigned to S1 input terminal (uses Switch Multilevel command class). |
4 | 5 | On/Off (S2) is assigned to S2 input terminal (uses Basic command class). |
5 | 5 | u0022Dimmer (S2)u0022 is assigned to S2 input terminal (uses Switch Multilevel command class). |
This parameter determines if the device will return to state prior to the power failure after power is restored. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 1 | Restore state after power failure |
This parameter defines as what type the device should treat the switch connected to the S1 and S2 terminals. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 2 | Switch type |
This parameter allows to define if the device sends reports during the flashing mode Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Flashing mode - reports |
This parameter defines how commands are sent in specified association groups: as secure or non-secure. Parameter is active only in Z-Wave network security mode. This parameter does not apply to 1st Lifeline group.Parameter 27 values may be combined, e.g. 1+2=3 means that 2nd and 3rd groups are sent as secure. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 15 | Associations in Z-Wave network security mode |
This parameter determines which actions result in sending scene IDs assigned to them.Parameter 28 values may be combined, e.g. 1+2=3 means that scenes for single and double click are sent. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 15 | S1 switch - scenes sent |
This parameter determines which actions result in sending scene IDs assigned to them.Parameter 29 values may be combined, e.g. 1+2=3 means that scenes for single and double click are sent. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 15 | S2 switch - scenes sent |
This parameter determines which actions are ignored when sending commands to devices associated in 2nd and 3rd association group. All actions are active by default.Parameter 30 values may be combined, e.g. 1+2=3 means that associations for turning ON and OFF are not sent.*Hold and release is inactive when parameter 20 is set to 1 or 2.**Double click is inactive when parameter 20 is set to 1. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 8 | S1 switch - associations sent to 2nd and 3rd association groups |
This parameter defines value sent with Switch ON command to devices associated in 2nd and 3rd association group. Size: 2 Byte, Default Value: 255
Setting | Description |
---|---|
0 - 255 | S1 switch - Switch ON value sent to 2nd and 3rd association groups |
This parameter defines value sent with Switch OFF command to devices associated in 2nd and 3rd association group. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 255 | S1 switch - Switch OFF value sent to 2nd and 3rd association groups |
This parameter defines value sent with Double Click command to devices associated in 2nd and 3rd association group. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 255 | S1 switch - Double Click value sent to 2nd and 3rd association groups |
This parameter defines value sent with Double Click command to devices associated in 2nd and 3rd association group. Size: 2 Byte, Default Value: 99
Setting | Description |
---|---|
0 - 255 | S1 switch - Double Click value sent to 2nd and 3rd association groups |
This parameter allows to choose operating for the 1st channel controlled by the S1 switch. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 5 | First channel - operating mode |
his parameter determines which actions result in sending commands to devices associated in 4th and 5th association group. All actions are active by default. Parameter 35 values may be combined, e.g. 1+2=3 means that associations for turning ON and OFF are not sent.*Hold and release is inactive when parameter 20 is set to 1 or 2.**Double click is inactive when parameter 20 is set to 1 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 8 | S2 switch - associations sent to 4th and 5th association groups |
This parameter defines value sent with Switch ON command to devices associated in 4th and 5th association group. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 255 | S2 switch - Switch ON value sent to 4th and 5th association groups |
This parameter defines value sent with Switch OFF command to devices associated in 4th and 5th association group. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 255 | S2 switch - Switch OFF value sent to 4th and 5th association groups |
This parameter defines value sent with Double Click command to devices associated in 4th and 5th association group. Size: 2 Byte, Default Value: 99
Setting | Description |
---|---|
0 - 255 | S2 switch - Double Click value sent to 4th and 5th association groups |
This parameter determines how the device will react to General Alarm frame. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
0 - 3 | Reaction to General Alarm |
This parameter determines how the device will react to Flood Alarm frame. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 - 3 | Reaction to Flood Alarm |
This parameter determines how the device will react to CO, CO2 or Smoke frame. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
0 - 3 | Reaction to CO/CO2/Smoke Alarm |
This parameter determines how the device will react to Heat Alarm frame. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 3 | Reaction to Heat Alarm |
This parameter allows to set duration of flashing alarm mode. Size: 2 Byte, Default Value: 600
Setting | Description |
---|---|
0 - 32000 | Flashing alarm duration |
This parameter determines the minimum change in consumed power that will result in sending new power report to the main controller. Size: 1 Byte, Default Value: 20
Setting | Description |
---|---|
0 - 100 | First channel - power reports |
This parameter determines how the device in timed mode reacts to pushing the switch connected to the S1 terminal. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 2 | reaction to switch for delay/auto ON/OFF modes |
This parameter determines minimum time that has to elapse before sending new power report to the main controller Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 - 120 | First channel - minimal time between power reports |
This parameter determines the minimum change in consumed energy that will result in sending new energy report to the main controller. Size: 2 Byte, Default Value: 100
Setting | Description |
---|---|
0 - 32000 | First channel - energy reports |
This parameter determines the minimum change in consumed power that will result in sending new power report to the main controller. Size: 1 Byte, Default Value: 20
Setting | Description |
---|---|
0 - 100 | Second channel - power reports |
This parameter determines minimum time that has to elapse before sending new power report to the main controller. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 - 120 | Second channel - minimal time between power reports |
This parameter determines the minimum change in consumed energy that will result in sending new energy report to the main controller. Size: 2 Byte, Default Value: 100
Setting | Description |
---|---|
0 - 32000 | Second channel - energy reports |
This parameter determines in what time interval the periodic power reports are sent to the main controller Size: 2 Byte, Default Value: 3600
Setting | Description |
---|---|
0 - 32000 | Periodic power reports |
This parameter determines in what time interval the periodic energy reports are sent to the main controller. Size: 2 Byte, Default Value: 3600
Setting | Description |
---|---|
0 - 3600 | Periodic energy reports |
This parameter determines whether energy metering should include the amount of energy consumed by the device itself. Results are being added to energy reports for first endpoint. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Measuring energy consumed by the device itself |
This parameter allows to set time parameter used in timed modes. Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
0 - 32000 | time parameter for delay/auto ON/OFF modes |
This parameter allows to set time of switching to opposite state in flashing mode Size: 2 Byte, Default Value: 5
Setting | Description |
---|---|
0 - 32000 | pulse time for flashing mode |
This parameter allows to choose operating for the 1st channel controlled by the S2 switch. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 5 | Second channel - operating mode |
This parameter determines how the device in timed mode reacts to pushing the switch connected to the S2 terminal. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 2 | Second channel - reaction to switch for delay/auto ON/OFF modes |
This parameter allows to set time parameter used in timed modes. Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
0 - 32000 | Second channel - time parameter for delay/auto ON/OFF modes |
This parameter allows to set time of switching to opposite state in flashing mode. Size: 2 Byte, Default Value: 5
Setting | Description |
---|---|
1 - 32000 | Second channel - pulse time for flashing mode |
Hardware Platform | ZM5101 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 3 FW: 3.04 |
Z-Wave Version | 6.51.07 |
Certification ID | ZC10-22047084 |
Z-Wave Product Id | 0x010F.0x0203.0x1000 |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |