This is a
Remotely controlled light dimming module is designed to work with various types of light sources. It may be connected to two-wire or three wire configuration so it can operate with or without neutral lead. Dimmer-Control can switch or dim connected light source either through radio waves or through the wall switch connected directly to it. New Dimmer-Control is equipped with an algorithm of smart light source detection which makes configuration easier and ensures high compatibility of the device. It may be used as a switch with non-dimmable light sources (in 3-wire connection).
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | u0022Lifelineu0022 reports the device status and allows for assigning single device only (main controller by default). |
2 | 8 | u0022On/Off (S1)u0022 is used to turn the associated devices on/off. |
3 | 8 | u0022Dimmer (S1)u0022 is used to set the associated devices to a certain level. |
4 | 8 | u0022On/Off (S2)u0022 is used to turn the associated devices on/off. |
5 | 8 | u0022Dimmer (S2)u0022 is used to set the associated devices to a certain level. |
This parameter is set automatically during the calibration process. The parameter can be changed manually after the calibration. The maximum brightness level (parameter 2) must be greater than the minimum brightness level (parameter 1). Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 - 98 | percentage level of brightness |
This parameter allows to automatically switch off the device after specified time from switching on the light source. It may be useful when Dimmer-Control is installed in the stairway Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 32767 | Timer functionality (auto - off) |
Parameter allows for activation/deactivation of Z-Wave commands enabling/disabling all devices located in direct range of the main controller Size: 2 Byte, Default Value: 255
Setting | Description |
---|---|
0 - 255 | ALL ON/ALL OFF function |
0 - 255 | ALL ON/ALL OFF function |
Changing value of this parameter will force the calibration process. During the calibration parameter is set to 1 or 2 and switched to 0 upon completion. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 2 | Force auto-calibration |
0 - 2 | Force auto-calibration |
This parameter determines operating mode of Dimmer-Control (automatic/manual settings). Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Auto-calibration status (read-only parameter) |
Function based on the sudden power variation of a specific value, interpreted as a LOAD ERROR. Parameter 15 is relevant only when parameter 58 is set to 0 and the control mode is consistent with the mode set during the calibration process (parameter 30). Size: 1 Byte, Default Value: 30
Setting | Description |
---|---|
0 - 99 | Burnt out bulb detection |
Time of delay (in seconds) for power variation detection, interpreted as a LOAD ERROR or OVERLOAD detection (too much power connected to Dimmer-Control). Size: 2 Byte, Default Value: 5
Setting | Description |
---|---|
0 - 255 | Time delay of a burnt out bul |
If the parameter is active, switching on Dimmer-Control (S1 single click) will always set this brightness level. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 99 | Forced switch on brightness level |
Choose between momentary, toggle and roller blind switch. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 2 | Choose between momentary |
This parameter defines the value sent to devices associated with Dimmer-Control after its enabling Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | The value sent to associated devices on single click |
By default each change of toggle switch position results in action of Dimmer-Control (switch on/off) regardless the physical connection of conntacts. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Assign toggle switch status to the device status |
This parameter is set automatically during the calibration process. The parameter can be changed manually after the calibration. The maximum brightness level (parameter 2) must be greater than the minimum brightness level (parameter 1). Size: 1 Byte, Default Value: 99
Setting | Description |
---|---|
2 - 99 | percentage level of brightness |
0 - double click disabled 1 - double click enabled Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Double click option - set the brightness level to MAX |
Parameter determines, which actions will not result in sending frames to association groups. Parameter 24 values may be combined, e.g. 1+2=3 means that associations on switching ON or OFF Dimmer-Control (single click) will not be sent. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 16 | Command frames sent in 2nd and 3rd association groups (S1 associations) |
Parameter determines, which actions will not result in sending frames to association groups. Parameter 25 values may be combined, e.g. 1+2=3 means that associations on switching ON or OFF Dimmer-Control (single click) will not be sent. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 16 | Command frames sent in 4th and 5th association groups |
Switch no. 2 controls Dimmer-Control additionally (in 3-way switch mode). Function disabled for parameter 20 set to 2 (roller blind switch). Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | The function of 3-way switch |
Parameter 27 values may be combined, e.g. 1+2=3 means that 2nd & 3rd group are sent as secure Size: 1 Byte, Default Value: 15
Setting | Description |
---|---|
0 - 15 | Associations in Z-Wave network security mode |
SCENE ID depends on the switch type configurations (see Table A5). Enabling scene activation functionality may cause slight delay in response to external switches and sending associations. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Scene activation functionality |
This parameter allows for switching the role of keys connected to S1 and S2 without changes in connection. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Switch functionality of S1 and S2 |
This parameter allows to set the desired load control mode. The device automatically adjusts correct control mode, but the installer may force its change using this parameter.Forced auto-calibration will set this parameters value to 2. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 - 2 | Load control mode |
This parameter allows to set the desired load control mode. The device automatically adjusts correct control mode, but the installer may force its change using this parameter.Forced auto-calibration will set this parameters value to 2. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Load control mode recognized during auto-calibration |
This mode is necessary while connecting non-dimmable light sources. Setting this parameter to 1 automatically ignores brightening/dimming time settings. Forced auto-calibration will set this parameters value to 2. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 - 2 | On/Off mode |
Virtual value set as a percentage level between parameters MIN (1%) and MAX. (99%). The Dimmer-Control will set to this value after first switch on. It is required for warming up and switching dimmable compact fluorescent lamps and certain types of light sources. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 - 99 | percentage level of brightness |
his parameter contains an information about possibility of dimming the load detected during calibration procedure Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Dimmability of the load |
Time required to warm up the filament of halogen bulb. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 2 | Soft-Start functionality |
This parameter determines the trigger of auto-calibration procedure, e.g. power on, load error, etc. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 4 | Auto-calibration after power on |
Occuring of errors related to surge or overcurrent results in turning off the output to prevent possible malfunction. By default the device performs three attempts to turn on the load (useful in case of momentary, short failures of the power supply. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Behaviour of Dimmer-Control after OVERCURRENT or SURGE |
Correction reduces spontaneous flickering of some capacitive load (e.g. dimmable LEDs) at certain brightness levels in 2-wire installation. In countries using ripple-control, correction may cause changes in brightness. In this case it is necessary to disable correction or adjust time of correction for flickering loads. Size: 2 Byte, Default Value: 255
Setting | Description |
---|---|
0 - 255 | Brightness level correction for flickering loads |
Reaching the defined value will result in turning off the load. Additional apparent power limit of 350VA is active by default. Parameter 39 is relevant only when parameter 58 is set to 0. Size: 2 Byte, Default Value: 250
Setting | Description |
---|---|
0 - 350 | Power limit - OVERLOAD |
0 - No reaction 1 - Turn on the load 2 - Turn off the load 3 - Load blinking Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
0 - 3 | Response to General Purpose Alarm |
0 - No reaction 1 - Turn on the load 2 - Turn off the load 3 - Load blinking Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 - 3 | Response to Water Flooding Alarm |
0 - No reaction 1 - Turn on the load 2 - Turn off the load 3 - Load blinking Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
0 - 3 | Response to Smoke, CO or CO2 Alarm |
0 - No reaction 1 - Turn on the load 2 - Turn off the load 3 - Load blinking Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 3 | Response to Temperature Alarm |
This parameter determines the time required for switching compact fluorescent lamps and certain types of light sources. Setting this parameter to 0 will disable the incandescence functionality Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
1 - 25 | time of dimmable compact fluorescent lamps |
Time of alarm state Size: 2 Byte, Default Value: 600
Setting | Description |
---|---|
1 - 32767 | Time of alarm state |
0 - No reaction 1 - Send an alarm frame Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 1 | OVERLOAD alarm report |
0 - No reaction 1 - Send an alarm frame Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 1 | LOAD ERROR alarm report |
0 - No reaction 1 - Send an alarm frame Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | OVERCURRENT alarm report |
0 - No reaction 1 - Send an alarm frame Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 1 | SURGE alarm report |
0 - No reaction 1 - Send an alarm frame Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 1 | OVERHEAT (critical temperature) and VOLTAGE DROP |
The parameter defines the power level change that will result in a new power report being sent. The value is a percentage of the previous report. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 - 100 | Active power reports |
Parameter 52 defines a time period between consecutive reports. Timer is reset and counted from zero after each report Size: 2 Byte, Default Value: 3600
Setting | Description |
---|---|
0 - 32767 | Periodic active power and energy reports |
Energy level change which will result in sending a new energy report. Size: 2 Byte, Default Value: 10
Setting | Description |
---|---|
0 - 255 | Energy reports |
The Dimmer-Control may include active power and energy consumed by itself in reports sent to the main controller. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Self-measurement |
This parameter defines the percentage value of dimming step during the automatic control. Automatic control is performed through:- single push-button click- double push-button click- Z-Wave control frames Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 - 99 | dimming step percentage value |
This parameter defines how to calculate active power. It is useful in a case of 2-wire connection with light sources other than resistive. Parameter 58 is set to 0 after forced auto-calibration. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 2 | Method of calculating the active power |
This parameter determines the approximate value of the power that will be reported by the device at its maximum brightness level. Parameter 59 works only when parameter 58 has a value other than 0. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 500 | Approximated power at the maximum brightness level |
This parameter defines the time of single dimming step set in parameter 5 during the automatic control. Size: 2 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 255 | time of a dimming step |
This parameter defines the percentage value of dimming step during the manual control. Manual control is performed through holding the push-button Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 - 99 | dimming step percentage value |
This parameter defines the time of single dimming step set in parameter 7 during the manual control. Size: 2 Byte, Default Value: 5
Setting | Description |
---|---|
0 - 255 | time of a dimming step |
The Dimmer-Control will return to the last state before power failure. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 1 | state before power failure. |
Hardware Platform | ZM5202 |
Device Type | Light Dimmer Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 2 FW: 3.05:03.05 |
Z-Wave Version | 6.51.07 |
Certification ID | ZC10-22037071 |
Z-Wave Product Id | 0x010F.0x0102.0x1000 |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |