Quickstart

This is a secure On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

Smart plug is a Z-Wave Switch plugin module specifically used to enable Z-Wave command and control (on/off) of any plug-in tool.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Group 1: Lifeline Group

Configuration Parameters

Parameter 151: Threshold of power report

Set the power threshold. When the load power value exceeds this threshold, the smart plug will send a power report to the associated device (Lifeline Group).
Size: 2 Byte, Default Value: 50

Setting Description
0 - 200 Available values: 0 - 200 (0 - 200W)
0 0 - The function is disabled.

Parameter 152: Percentage threshold for power reporting

Set the power percentage threshold. When the load power percentage value exceeds this threshold, the smart plug will send a power report to the associated device (Lifeline Group).
Size: 1 Byte, Default Value: 10

Setting Description
0 The function is disabled.
0 - 100 Available values: 0 - 100 (0 - 100%)

Parameter 171: Frequency of power reports

Defines how often power reports are sent to associated devices (Lifeline Group).
Size: 4 Byte, Default Value: 3600

Setting Description
0 The function is disabled.
3600 - 2678400 Available values: 3600- 2678400 (3600 - 2678400s)

Parameter 172: Frequency of energy reports

Defines how often energy reports are sent to associated devices (Lifeline Group).
Size: 4 Byte, Default Value: 7200

Setting Description
0 The function is disabled.
3600 - 2678400 Available values: 3600- 2678400 (3600 - 2678400s)

Parameter 173: Frequency of voltage reports

Defines how often voltage reports are sent to associated devices (Lifeline Group).
Size: 4 Byte, Default Value: 0

Setting Description
0 The function is disabled.
3600 - 2678400 Available values: 3600- 2678400 (3600 - 2678400s)

Parameter 174: Frequency of electric current reports

Defines how often electric current reports are sent to associated devices (Lifeline Group).
Size: 4 Byte, Default Value: 0

Setting Description
0 The function is disabled.
3600 - 2678400 Available values: 3600- 2678400 (3600 - 2678400s)

Parameter 20: Overload protection

Smart Plug keep detecting the load power, once the AC current exceeds 11.5A for more than 5s, smart plug's relay will turn off.
Size: 1 Byte, Default Value: 1

Setting Description
0 The function is disabled
1 The function is enabled.

Parameter 21: Device state after power on

Defines the state of the plug when the power is turned on.
Size: 1 Byte, Default Value: 0

Setting Description
0 The Smart Plug will remain in the same state as it was before the power off.
1 The smart plug is turned on by default.
2 The smart plug is turned off by default.

Parameter 24: Send reports when load status changes

Defines whether to send report to the associated device (Lifeline Group) when the load status of the Smart Plug changes.
Size: 1 Byte, Default Value: 1

Setting Description
0 The function is disabled.
1 Send Basic report.
2 Send Basic report only when Load condition is not changed by Z-WAVE Command.

Parameter 254: Enable/Disable the configuration command

Enable:The values of other parameters can be changed.Disable:The values of other parameters cannot be changed.
Size: 1 Byte, Default Value: 0

Setting Description
0 Enable
1 Disable

Parameter 27: The state of indicator light

Define the corresponding state of the indicator light when the load changes.
Size: 1 Byte, Default Value: 0

Setting Description
0 The indicator light remains the same as the load on/off status. When the load is on, the light is on. When the load is off, the light is off.
1 Within 5 seconds after the operation load, the indicator light is consistent with the load on/off status, and then the indicator turns off.

Technical Data

Hardware Platform ZM5202
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.02
Z-Wave Version 6.81.01
Certification ID ZC10-22017070
Z-Wave Product Id 0x0208.0x0102.0x0029
Firmware Updatable
Supported Meter Type
Neutral Wire Required ok
Switch Type
Color
Communications Protocol
Electric Load Type
Frequency XXfrequency
Maximum transmission power XXantenna
On/Off Power Switch