Quickstart

This is a secure Door Lock - Keypad for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

Danalock supports:- S0/S2 Z-Wave Security- Bluetooth Smart - Twist Assist- Auto-Lock- Hold And Release- End to End

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Z-Wave Plus Lifeline Device Reset Locally: triggered upon reset. Battery/notification: triggered upon low battery. Door Lock operation report: triggered upon a change in door lock Notification: triggered upon a change in door lock

Configuration Parameters

Parameter 1: Twist Assist

Helps you to lock and unlock your door lock.
Size: 1 Byte, Default Value: 0

Setting Description
0 Disabled
1 Enabled

Parameter 2: Hold and Release

After a unlock operation the lock holds the lock, so the door can be opened
Size: 4 Byte, Default Value: 0

Setting Description
0 Disable
1 - 2147483647 Enable no. of seconds

Parameter 3: Block to Block

The lock will run the motor until it hits resistance.
Size: 1 Byte, Default Value: 0

Setting Description
0 Disable
1 Enable

Parameter 4: BLE Temporary Allowed

The BLE is enabled for a number of seconds.
Size: 4 Byte, Default Value: 0

Setting Description
1 - 2147483647 Enable no. of seconds

Parameter 5: BLE Always Allowed


Size: 1 Byte, Default Value: 0

Setting Description
0 BLE Always disabled
1 BLE Always enabled

Parameter 6: Autolock

Lock after an unlock. The value is the delay in time before the lock is locked again.
Size: 4 Byte, Default Value: 0

Setting Description
0 Diable
1 - 2147483647 Enable no. of seconds

Technical Data

Hardware Platform ZM5202
Device Type Door Lock - Keypad
Network Operation Listening Sleeping Slave
Firmware Version HW: 2 FW: 1.03:00.10
Z-Wave Version 6.71.03
Certification ID ZC10-21107059
Z-Wave Product Id 0x010E.0x0009.0x0001
Supported Notification Types Access Control
Firmware Updatable Updatable by Consumer by RF
Frequency XXfrequency
Maximum transmission power XXantenna
Door Lock - Keypad