Product features: OLED display and touch buttons also as remote control other thermostatsfor heating Internal sensor for room temperature , externalInternal sensor for floor temperature Max Load 3680W @ 230V (resistive load),16A Alarm: over current, room temperature over heat Electric power measurement Internal overheatingprotection
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Lifelinesame main report |
2 | 5 | Transfer Command Class THERMOSTAT_SETPOINT_SET THERMOSTAT_MODE_SET to control other Thermostatwhen operationchanges |
Temperature control reference selection Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | room sensor |
2 | floor sensor |
3 | room+floor sensor |
ROOM SENSOR temperature compensation setting,unit is 0.5 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-10 - 10 | value is-5~5 |
FLOOR SENSOR temperature compensation setting,unit is 0.5 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-10 - 10 | value is -5~5 |
Set how long the drying mode lasts, unit is minute Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
5 - 100 | value is5~100 minutes |
Set the mode after the drying mode ends Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | OFF |
1 | Manual mode (comfort mode) |
2 | Auto mode (energy save mode) |
3 | Away mode |
When to report temperature relative change threshold value actively, unit is 0.1 Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | disable to report |
2 - 10 | report when the threshold value is 0.2 - 1 |
Time interval value for periodic report of temperature, humidity, unit is S. Size: 2 Byte, Default Value: 300
Setting | Description |
---|---|
0 | disable to report |
30 - 28800 | report when time interval value is 30~28800 s |
When to report power change absolute threshold, unit is W Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 | disable to report |
1 - 100 | report when absolute threshold is 1W~100W |
When to report current change absolute threshold, unit is 0.1A Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 | disable to report |
1 - 10 | report when absolute threshold is 0.1A~1A |
Over current detection max. value, unit is A. When detected current is over thisvalue, the device will turn off the relay and send NOTIFICATION CC. Size: 1 Byte, Default Value: 16
Setting | Description |
---|---|
0 | disable over current detection |
5 - 16 | over current detection max value |
When to report voltage change absolute threshold, unit is 1 V Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | disable to report |
1 - 10 | report when absolute threshold is 1~10 V |
Time interval value for periodic active report of Meterunit is S Size: 4 Byte, Default Value: 600
Setting | Description |
---|---|
60 - 2678400 | value is60~2678400 s |
The OLED display brightness when operate the device. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 2 | low levelmid levelhigh level |
is parameter defines which sensor temperature will be displayed on Home page Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | indoor air temperature |
1 | external temperature (floor temperature) |
The time zone that the time parameters command adopts is UTC the time zone need to be set. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-12 - 12 | value is-12~12 |
Window open detect function temperature threshold: the Celsius degrees that the temperature decreases within 3 minutes, unit is 0.1 Celsius degree. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | disbaled |
15 - 40 | the set temperature threshold |
Vibration level triggered by pressing buttons Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | disable vibration and buzzer |
1 | Low Level |
2 | High Level |
Whether to recover to settings before power failure or power reset. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | use default settings |
1 | recover to settings before power failure or power reset |
High temperature detection max. value, unit is , when either temperature sensor is higher than this value, the device will turn off the relay and send NOTIFICATION CC. Size: 1 Byte, Default Value: 45
Setting | Description |
---|---|
0 | disable this function |
20 - 60 | air temperature over value |
Temperature control hysteresis value setting, setting range 0.5-2,unit is 0.1 Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
5 - 20 | hysteresis value0.5~2 |
Auto mode (Energy save mode) temperature schedule. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | use schedule set by user |
1 | use Energy_Save_Heating temperature set by THERMOSTAT_SETPOINT_SET |
Select floor temperature sensor type Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | NTC/10K B(25/50)=3950 |
2 | NTC/15K B(25/50)=3950 |
3 | NTC/50K B(25/50)=3950 |
4 | NTC/100K B(25/50)=3950 |
Hardware Platform | ZM5101 |
Device Type | Thermostat - HVAC |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.24 |
Z-Wave Version | 6.82.00 |
Certification ID | ZC10-21097049 |
Z-Wave Product Id | 0x0330.0x0200.0xD013 |
Thermostat Power Source | |
Thermostat HVAC Systems Supported | Heat Only |
Thermostat Modes | Auto Changeover |
Electric Load Type | |
Firmware Updatable | Not Updatable |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |