Quickstart

This is a secure On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.Each module is designed to act as a repeater,which will re-transmit a radio frequency (RF) signal by routing the signal ,around obstacles and radio dead spots to ensure that the signal is received at its intended destination.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 3 Z-Wave Lifeline
2 5 When the output of the N4001 socket is changed, On (0xFF) or Off (0x00). The N4001 will automatically send out a relatedb a s i c Osne t(0 cxoFmFm)a onrd. Off (0x00) to its associated group.

Configuration Parameters

Parameter 1: Status LED

Status LED Configuration
Size: 1 Byte, Default Value: 0

Setting Description
0 LED on when relay on, LED off when relay off
1 LED on when relay off, LED off when relay on
2 LED Always OFF

Parameter 2: Count Down Configuration

Count Down ConfigurationThe countdown time, the socket closed
Size: 2 Byte, Default Value: 0

Setting Description
0 - 32767 Countdown time can be set up for this time

Technical Data

Hardware Platform ZM5202
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 255 FW: 1.255
Z-Wave Version 6.71.01
Certification ID ZC10-21087048
Z-Wave Product Id 0x0312.0xAC01.0x4001
Firmware Updatable Updatable by Consumer by RF
Color White
Electric Load Type FluorescentIncandescentLED
Frequency XXfrequency
Maximum transmission power XXantenna
On/Off Power Switch