This is a secure On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The Inovelli Red Series On/Off is a Z-Wave in-wall switch that controls attached LED, CFL, & Incandescent lighting which can be highly customized to your liking at the switch itself with our unique config button and advanced firmware. In addition, the Red Series comes with advanced features such as scene support, power monitoring, notifications, local protection, etc.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Members of this group will receive unsolicited messages related to the status of the switch.
2 5 1. Single press up button sends BasicSet (0xFF) and 2. Single press down sends BasicSet (0x00).

Configuration Parameters

Parameter 1: Power On State

When power is restored, the switch reverts to either On, Off, or Last Level.
Size: 1 Byte, Default Value: 0

Setting Description
0 When Power is restored, switch returns to state prior to power outage
1 When Power is restored, switch turns ON
2 When Power is restored, switch is OFF

Parameter 10: Active Power Alerts

The power level change that will result in a new power report being sent (% of previous report). Example of how the values work: 0 = Disabled, 10 = 10% of previous report, 100 = 100% of previous report.
Size: 1 Byte, Default Value: 10

Setting Description
0 Disabled
1 - 100 Percentage of previous report

Parameter 11: Periodic Power + Energy Reports

Time period between consecutive power and energy reports being sent (in seconds). Example of how the values work: 0 = 0 seconds, 1 = 1 second, 32767 = 32767 seconds. The timer resets after every report is sent.
Size: 2 Byte, Default Value: 3600

Setting Description
0 - 32767 Seconds

Parameter 12: Energy Reports

The energy level change that will result in a new energy report being sent (% of previous report). Example of how the values work: 0 = Disabled, 10 = 10% of previous report, 100 = 100% of previous report.
Size: 1 Byte, Default Value: 10

Setting Description
0 Disabled
1 - 100 Percentage of previous report

Parameter 2: Invert Switch

Inverts the switch (Tap Down = On, Tap Up = Off). Example of how the values work: 0 = Disabled, 1 = Enabled. This parameter can be set without a HUB from the Configuration Button.
Size: 1 Byte, Default Value: 0

Setting Description
0 Disabled
1 Enabled

Parameter 3: Auto Off Timer

Automatically turns the switch off after x amount of seconds. Example of how the values work: 0 = Disabled, 1 = 1 second, 32767 = 32767 seconds.
Size: 2 Byte, Default Value: 0

Setting Description
0 Disabled
1 - 32767 Seconds

Parameter 4: Association Behavior

When should the switch send commands to associated devices.
Size: 1 Byte, Default Value: 15

Setting Description
1 Local
2 3-Way
3 3-Way + Local
4 Z-Wave HUB
5 Z-Wave HUB + Local
6 Z-Wave HUB + 3-Way
7 Z-Wave HUB + Local
8 Timer
9 Timer + Local
10 Timer + 3-Way
11 Timer + Local
12 Timer + Z-Wave HUB
13 Timer + Local
14 Timer + Z-Wave HUB
15 All

Parameter 5: LED Indicator Color

This will set the default color of the LED Bar. This is calculated by using a hue color circle (Value / 255 * 360). See website for more info. This parameter can be set without a HUB from the Configuration Button.
Size: 2 Byte, Default Value: 170

Setting Description
0 - 255 Hue Color Circle
170 Blue

Parameter 51: Disable 700ms Delay

Disables the 700ms delay. Note, if you disable the delay, it will also disable scene control except for Button 1 (ie: tap up 1x or tap down 1x) and button 7 (config button). All other buttons (2-6) will be disabled.
Size: 1 Byte, Default Value: 1

Setting Description
0 700ms Delay Disabled
1 700ms Delay Enabled

Parameter 6: LED Indicator Intensity

This will set the intensity of the LED bar (ie: how bright it is). Example of how the values work: 0 = Off, 1 = Low, 5 = Medium, 10 = High. This parameter can be set without a HUB from the Configuration Button.
Size: 1 Byte, Default Value: 5

Setting Description
0 Off
1 - 3 Low Intensity
4 - 7 Medium Intensity
8 - 10 High Intensity

Parameter 7: LED Indicator Intensity (When Off)

This is the intensity of the LED bar when the switch is off. Example of how the values work: 0 = Off, 1 = Low, 5 = Medium, 10 = High. This parameter can be set without a HUB from the Configuration Button.
Size: 1 Byte, Default Value: 1

Setting Description
0 Off
1 - 3 Low Intensity
4 - 7 Medium Intensity
8 - 10 High Intensity

Parameter 8: LED Strip Effect

This will allow you to add some sweet effects to your LED bar (ie: pulse, chase, solid, etc). Example of how the values work: Byte 1 = Choose Color, Byte 2 = Choose Brightness Level, Byte 3 = Choose Effect, Byte 4 = Duration. Please see website for further instructions on how to set this up as the possible values are a matrix. You start with Byte 1 to select the color, then move to Byte 2 to select the Brightness Level, then move to Byte 3 to choose the Effect, and finally move to Byte 4 to choose the Duration.
Size: 4 Byte, Default Value: 0

Setting Description
0 Please see website for matrix - https://nathanfiscus.github.io/inovelli-notification-calc/

Technical Data

Hardware Platform ZM5101
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.21
Z-Wave Version 6.81.03
Certification ID ZC10-21067042
Z-Wave Product Id 0x031E.0x0002.0x0001
Frequency XXfrequency
Maximum transmission power XXantenna
On/Off Power Switch