Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
The Inovelli Red Series On/Off is a Z-Wave in-wall switch that controls attached LED, CFL, & Incandescent lighting which can be highly customized to your liking at the switch itself with our unique config button and advanced firmware. In addition, the Red Series comes with advanced features such as scene support, power monitoring, notifications, local protection, etc.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Members of this group will receive unsolicited messages related to the status of the switch. |
2 | 5 | 1. Single press up button sends BasicSet (0xFF) and 2. Single press down sends BasicSet (0x00). |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
When power is restored, the switch reverts to either On, Off, or Last Level. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | When Power is restored, switch returns to state prior to power outage |
1 | When Power is restored, switch turns ON |
2 | When Power is restored, switch is OFF |
The power level change that will result in a new power report being sent (% of previous report). Example of how the values work: 0 = Disabled, 10 = 10% of previous report, 100 = 100% of previous report. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 | Disabled |
1 - 100 | Percentage of previous report |
Time period between consecutive power and energy reports being sent (in seconds). Example of how the values work: 0 = 0 seconds, 1 = 1 second, 32767 = 32767 seconds. The timer resets after every report is sent. Size: 2 Byte, Default Value: 3600
Setting | Description |
---|---|
0 - 32767 | Seconds |
The energy level change that will result in a new energy report being sent (% of previous report). Example of how the values work: 0 = Disabled, 10 = 10% of previous report, 100 = 100% of previous report. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 | Disabled |
1 - 100 | Percentage of previous report |
Inverts the switch (Tap Down = On, Tap Up = Off). Example of how the values work: 0 = Disabled, 1 = Enabled. This parameter can be set without a HUB from the Configuration Button. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disabled |
1 | Enabled |
Automatically turns the switch off after x amount of seconds. Example of how the values work: 0 = Disabled, 1 = 1 second, 32767 = 32767 seconds. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disabled |
1 - 32767 | Seconds |
When should the switch send commands to associated devices. Size: 1 Byte, Default Value: 15
Setting | Description |
---|---|
1 | Local |
2 | 3-Way |
3 | 3-Way + Local |
4 | Z-Wave HUB |
5 | Z-Wave HUB + Local |
6 | Z-Wave HUB + 3-Way |
7 | Z-Wave HUB + Local |
8 | Timer |
9 | Timer + Local |
10 | Timer + 3-Way |
11 | Timer + Local |
12 | Timer + Z-Wave HUB |
13 | Timer + Local |
14 | Timer + Z-Wave HUB |
15 | All |
This will set the default color of the LED Bar. This is calculated by using a hue color circle (Value / 255 * 360). See website for more info. This parameter can be set without a HUB from the Configuration Button. Size: 2 Byte, Default Value: 170
Setting | Description |
---|---|
0 - 255 | Hue Color Circle |
170 | Blue |
Disables the 700ms delay. Note, if you disable the delay, it will also disable scene control except for Button 1 (ie: tap up 1x or tap down 1x) and button 7 (config button). All other buttons (2-6) will be disabled. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | 700ms Delay Disabled |
1 | 700ms Delay Enabled |
This will set the intensity of the LED bar (ie: how bright it is). Example of how the values work: 0 = Off, 1 = Low, 5 = Medium, 10 = High. This parameter can be set without a HUB from the Configuration Button. Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 | Off |
1 - 3 | Low Intensity |
4 - 7 | Medium Intensity |
8 - 10 | High Intensity |
This is the intensity of the LED bar when the switch is off. Example of how the values work: 0 = Off, 1 = Low, 5 = Medium, 10 = High. This parameter can be set without a HUB from the Configuration Button. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Off |
1 - 3 | Low Intensity |
4 - 7 | Medium Intensity |
8 - 10 | High Intensity |
This will allow you to add some sweet effects to your LED bar (ie: pulse, chase, solid, etc). Example of how the values work: Byte 1 = Choose Color, Byte 2 = Choose Brightness Level, Byte 3 = Choose Effect, Byte 4 = Duration. Please see website for further instructions on how to set this up as the possible values are a matrix. You start with Byte 1 to select the color, then move to Byte 2 to select the Brightness Level, then move to Byte 3 to choose the Effect, and finally move to Byte 4 to choose the Duration. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Please see website for matrix - https://nathanfiscus.github.io/inovelli-notification-calc/ |
Hardware Platform | ZM5101 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.21 |
Z-Wave Version | 6.81.03 |
Certification ID | ZC10-21067042 |
Z-Wave Product Id | 0x031E.0x0002.0x0001 |
Security V2 | S2_UNAUTHENTICATED ,S2_AUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |