Quickstart

This is a secure On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

In-Wall Smart Switch with QuickFit and SimpleWire enhancements. Revolutionary QuickFit design features a housing depth that is up to 20 percent smaller than the previous Z-Wave models. This reduced size coupled with the elimination of heat taps provides a better fit in older style boxes and multi-gang configurations. SimpleWire technology allows line and load to automatically be configured with auto-sensing line-load terminals. All of this is coupled with Z-Wave S2 and Smart Start allows for effortless installation while being safer than ever!

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus Lifeline
2 5 Supports Basic Set and is controlled by pressing the ON or OFF button with the local load.
3 5 Supports Basic Set and is controlled by double pressing the ON or OFF button.

Configuration Parameters

Parameter 19: Alternate Exclusion

Default - normal exclusionActive - perform a series of button presses to help eliminate accidental exclusion
Size: 1 Byte, Default Value: 0

Setting Description
0 Press any button on the switch
1 Press two times ON button and two time OFF button, LED will flash 5 times if successful

Parameter 3: LED Indication Configuration

Configure LED indication to default, invert, always off or always on
Size: 1 Byte, Default Value: 0

Setting Description
0 LED ON when device is OFF, LED is OFF when device is ON
1 LED ON when device is ON, LED is OFF when device is OFF
2 LED always OFF
3 LED Always ON

Technical Data

Hardware Platform ZM5202
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 255 FW: 5.55
Z-Wave Version 6.81.03
Certification ID ZC10-21047017
Z-Wave Product Id 0x0063.0x4952.0x3136
Firmware Updatable
Neutral Wire Required ok
Z-Wave Scene Type
Frequency XXfrequency
Maximum transmission power XXantenna
On/Off Power Switch