Quickstart

This is a secure Light Dimmer Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

RGB Bulb is a smart bulb enables Z-Wave remote command and control (on/off/dim). It has over 16,000,000 colors, you can choose its color according to your favour.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus LifelineRGB BULB supports only one association groupings:RGB BULB will send the follow notification to the associated nodes whenthe status of the RGB BULB is changed.1. Set Configuration parameter 24 to 0: Reserved2. Set Configuration parameter 24 to 1: Send Basic Report3. Set Configuration parameter 24 to 2: Send Basic Report only when thestatus of the RGB BULB is not changed by Z-WAVE Command.

Configuration Parameters

Parameter 21: Setting device status after power failure

Define how the RGB BULB will react after the power supply is back on.
Size: 1 Byte, Default Value: 0

Setting Description
0 Define how the RGB BULB will react after the power supply is back on.
1 RGB BULB memorizes its state after a power failure.
2 RGB bulb does not memorize its state after a power failure.

Parameter 24: Notification when Load status change

RGB BULB can send notifications to associated device (Group Lifeline)when the status of the RGB BULB is changed.
Size: 1 Byte, Default Value: 1

Setting Description
0 The function is disabled
1 Send Basic report
2 Send BASIC REPORT only when the status of the RGB BULB is not changed by Z-WAVE command.

Parameter 255: Reset to factory default

RGB BULB will exclude from the Z-Wave network with thisparticular command.
Size: 4 Byte, Default Value: 1431655765

Setting Description
1431655765 Resetting to the factory default.

Technical Data

Hardware Platform ZM5101
Device Type Light Dimmer Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.01
Z-Wave Version 6.51.08
Certification ID ZC10-20117000
Z-Wave Product Id 0x0208.0x0102.0x0004
Firmware Updatable Updatable by Consumer by RF
Frequency XXfrequency
Maximum transmission power XXantenna
Light Dimmer Switch