Quickstart

This is a secure Wall Controller for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The Scene Controller is a wireless, portable and rechargeable scene switch. It can control a Z-Wave device, such as smart plug, smart dimmer with a Z-Wave gateway. You can also activate a scene like sleep scene, movie scene and entertainment scene with it.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 (Lifeline group) allows Scene Controller sends central scene notification command and battery report command when any button is triggered. Details shown as the below diagram 1.
2 5 allows Scene Controller sends basic set command when thebutton 1 is triggered
3 5 allows Scene Controller sends switch multilevel set, multilevel start level change and multilevel stop level change command when the button 1 is triggered.
4 5 allows Scene Controller sends basic set command when thebutton 2 is triggered.
5 5 allows Scene Controller sends switch multilevel set, multilevel start level change and multilevel stop level change command when the button 2 is triggered.
6 5 allows Scene Controller sends basic set command when thebutton 3 is triggered.
7 5 allows Scene Controller sends switch multilevel set, multilevel start level change and multilevel stop level change command when the button 3 is triggered.
8 5 allows Scene Controller sends basic set command when thebutton 4 is triggered.
9 5 allows Scene Controller sends switch multilevel set, multilevel start level change and multilevel stop level change command when the button 4 is triggered.

Configuration Parameters

Parameter 254: Enable/disable the configuration command

Lock/unlock all configuration parameters.
Size: 1 Byte, Default Value: 0

Setting Description
0 Unlock all configuration parameters.
1 Lock all configuration parameters

Parameter 255: Reset Scene Controller

Reset Scene Controller and remove from the Z-Wave network
Size: 4 Byte, Default Value: 1

Setting Description
1431655765 Reset Scene Controller and remove from the Z-Wave network

Technical Data

Hardware Platform ZM5101
Device Type Wall Controller
Network Operation Portable Slave
Firmware Version HW: 1 FW: 1.00
Z-Wave Version 6.51.08
Certification ID ZC10-20106991
Z-Wave Product Id 0x0208.0x0202.0x000B
Z-Wave Scene Type Central Scene
Frequency XXfrequency
Maximum transmission power XXantenna
Wall Controller