This is a
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
This Z-Wave module is used to control the motor of blinds, rollers, shades, venetian blinds, etcThe module can be controlled either through a Z-Wave network or through the wall switch.Precise positioning is supported for motors equipped with mechanical or electronic end switches. The module is designed to be mounted inside a flush mounting box, hidden behind a traditional wall switch. Module measures power consumption of motor and support connection of digital temperature sensor. It is designed to act as repeater in order to improve range and stability of Z-Wave network.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Lifeline group (reserved for communication with the primary gateway (hub)), 1 node allowed. |
2 | 16 | (Triggered at change of input I1) up to 16 nodes. When switch wired to input I1 is pressed ZOE Shutter U will send Basic set ON command to associated device and this device will turn ON, when it is released ZOE shutter sends Basic set OFF command to associated device and this device will turn OFF. |
3 | 16 | Basic on/off (Triggered at change of input I2) up to 16 nodes. When switch wired to input I2 is pressed ZOE Shutter U will send Basic set ON command to associated device and this device will turn ON, when it is released ZOE shutter U sends Basic set OFF command to associated device and this device will turn OFF. |
4 | 16 | When blinds are moving up, ZOE Shutter will send Basic set ON command to associated device and associated device will turn ON. When blinds are moving down, ZOE Shutter will send Basic set OFF command to associated device and the device will turn OFF. |
5 | 16 | Up to 16 nodes. When blinds reach upper position ZOE Shutter will send Basic set OFF command to associated device and the device will turn OFF. When blinds reach down position ZOE Shutter will send Basic set ON command to associated device and the device will turn ON. |
6 | 16 | Up to 16 nodes. When blinds reach down position, ZOE Shutter will send Basic set ON command and the device will turn ON. When blinds are in any position which is not down (0%) ZOE Shutter will send Basic set OFF to associated device and the device will turn OFF. |
7 | 16 | Up to 16 nodes. ZOE Shutter will set Switch multilevel command to associated device, the command is actual position of blinds so the associated device will turn on same level as blinds are. Example with association between ZOE Shutter and dimmer, when shutters blinds reach middle position 50% it will send switch multilevel set 50% command and dimmer will turn on 50%. |
8 | 16 | Up to 16 nodes. ZOE Shutter device will send Switch multilevel set command to associated device, the command is actual position of tilts.Example with association between ZOE shutter and dimmer. When shutters tilts rotate to middle position 50% it will send switch multilevel set 50% command and dimmer will turn on 50%. |
9 | 16 | Up to 16 nodes. ZOE Shutter U device will send Multilevel sensor report to associated device, this will send the information of actual temperature that was measured with temperature sensor. |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Available config. parameters (data type is 2 Byte DEC):default value 255255 - ALL ON active, ALL OFF active.0 - ALL ON is not active ALL OFF is not active1 - ALL ON is not active ALL OFF active2 - ALL ON active ALL OFF is not activeZoe Shutter responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controllers belonging to the system. Size: 2 Byte, Default Value: 255
Setting | Description |
---|---|
0 | ALL ON is not active ALL OFF is not active |
1 | ALL ON is not active ALL OFF active |
2 | ALL ON active ALL OFF is not active |
255 | ALL ON active, ALL OFF active. |
Set value is added or subtracted to actual measured value by sensor. Available configuration parameters (data type is 2 Byte DEC):default value 3253632536 - offset is 0.0CFrom 1 to 100 - value from 0.1 C to 10.0 C is added to actual measured temperature. From 1001 to 1100 - value from -0.1 C to -10.0 C is subtracted to actual measured temperature. Size: 2 Byte, Default Value: 32536
Setting | Description |
---|---|
32536 | offset is 0.0C |
1 - 100 | Where 1 stands for 0.1C and 100 stands for 10.0C added to the actual measurement. |
1001 - 1100 | Where 1001 stands for -0.1C and 1100 stands for -10.0C subtracted from the actual measurement. |
If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. Available configuration parameters (data type is 1 Byte DEC):default value 5 = 0,5C0 - Reporting disabled1-127 = 0,1C - 12,7C, step is 0,1C Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 | Reporting disabled |
1 - 127 | Where 1 stands for 0.1C and 127 stands for 12.7C. |
Set value means percentage, set value from 0100 = 0% - 100%. Available configuration parameters (data type is 1 Byte DEC): default value 10 = 10%0 - reporting disabled1 - 100 = 1% - 100% Reporting enabled. Power report is send (push) only when actual power (in Watts) in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%.NOTE: if power changed is less than 1W, the report is not send (pushed), independent of percentage set. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 | reporting disabled |
1 - 100 | 1% - 100% Power consumption reporting enabled. New value is reported only when the power consumption in real time changes by more than the percentage value set in this parameter, compared to the previous power consumption reading, starting at 1% (the lowest value possible). |
Set value means time interval (032767) in seconds, when power report is send. Available configuration parameters (data type is 2 Byte DEC): default value 0 = reporting disabled0 - reporting disabled1 - 32767 = 1 second - 32767 seconds. Reporting enabled, power report is send with time interval set by entered value. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Power consumption reporting disabled |
1 - 32767 | 1 - 32767 seconds. Power consumption reporting enabled. Report is sent according to time interval (value) set here |
This parameter defines selection between two available operating modes. Available configuration parameters (data type is 1 Byte DEC): default value 00 - Shutter mode1 - venetian mode (up/down and slate rotation)NOTE1: After parameter change, first exclude module (without setting parameters to default value) then wait at least 30s and then re include the module! Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Shutter mode |
1 | Venetian mode (up/down and slate rotation) |
This parameter defines the time necessary for slats to make full turn (180 degrees). Available configuration parameters (data type is 2 Byte DEC): default value 150 = 1,5 seconds0 - tilting time disabled1 - 32767 = 0,01seconds - 327,67 secondsNOTE: If time set is too high, this will result that after full turn, Shutter will start move up or down, for time remaining. Size: 2 Byte, Default Value: 150
Setting | Description |
---|---|
0 | tilting time disabled |
1 - 32767 | 0,01seconds - 327,67 seconds |
This parameter defines slats position after up/down movement through Z-Wave or push-buttons. Available configuration parameters (data type is 1 Byte DEC): default value 1 0 - Slats return to previously set position only in case of Z-Wave control (not valid for limit switch positions).1 - Slats return to previously set position in case of Z-Wave control, push-button operation or when the lower limit switch is reached. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Slats return to the previously set position only after being activated via the Z-Wave gateway (hub) (not valid for limit switch positions) |
1 | Slats return to the previously set position in case they were activated via the Z-Wave gateway (hub), push-button operation or when the lower limit switch is reached |
This parameter defines Shutter motor moving time of complete opening or complete closing.Available configuration parameters (data type is 2 Byte DEC): default value 00moving time disabled (working with limit switches)1 - 32767 = 0,1seconds - 3276,7secondsAfter that time motor is stopped (relay goes to off state)NOTE: Important is that the reference position to manually set moving time is always Shutter lower position!Set parameter 74 to 0 and move the Shutter (using up/down push buttons or main controller UI) to the lowest desired position. On this Shutter position, set parameter 74 to time for complete opening or complete closing. At this point Shutter can be moved up (open) for set time, but can't be moved down because this position is already set as lower Shutter position.To change Shutter lower position below already set (manual recalibration), parameter 74 must be set to 0 and repeat the procedure described above.In case Shutter has limit switches, but anyhow you would like to limit opening/closing position by time, you can still do it. In case you put time that is longer that opening/closing real time limited by limit switches, Shutter will stop at limit switch, but the module relay will switch off after define time, not by Shutter limit switch. Take in consideration that in this condition, the positioning with slider through UI will not show correct Shutter position. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | moving time disabled (working with limitswitches) |
1 - 32676 | 0.1 seconds3276.7 seconds |
Power threshold to be interpreted when motor reach the limit switch. Available configuration parameters (data type is 1 Byte DEC): default value 30 = 30W0 - 127 = 1-127 W. The value 0 means reaching a limit switch will not be detected. Size: 1 Byte, Default Value: 30
Setting | Description |
---|---|
0 | The value 0 means that reaching a limit switch will not be detected. |
1 - 127 | 1 - 127W The value 0 means reaching a limit switch will not be detected. |
By modifying the parameters setting from 0 to 1 a Shutter enters the calibration mode. Available configuration parameters (data type is 1 Byte DEC): default value 01 - Start calibration process (when calibration process is finished, completing full cycle - up, down and up, set the parameter 78 (Forced Shutter calibration) value back to 0. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Start calibration process (when calibration process is finished, completing full cycle - up, down and up, set the parameter 78 (Forced Shutter calibration) value back to 0. |
This parameter defines the max time before motor power consumption is read after one of the relays is switched ON.If there is no power consumption during this max time (motor not connected, damaged or requires higher time to start, motor in end position) the relay will switch OFF. Time is defined by entering it manually. Available configuration parameters (data type is 1 Byte DEC): default value 30 = 3s 0 = time is set automatically3 - 50 = 0,3seconds - 5seconds (100ms resolution) Size: 1 Byte, Default Value: 30
Setting | Description |
---|---|
0 | time is set automatically |
3 - 50 | 0,3seconds - 5seconds (100ms resolution) |
This parameter defines the minimum time delay between next motor movement (minimum time between switching motor off and on again). Available configuration parameters (data type is 1 Byte DEC): default value 5 = 500ms1 - 30 = 0,1seconds - 3seconds (100ms resolution) Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
1 - 30 | 0.1seconds - 3seconds (100ms resolution) |
5 | 500ms |
Hardware Platform | ZM5202 |
Device Type | Window Covering - Pos/End Aware |
Network Operation | Always On Slave |
Firmware Version | HW: 2 FW: 6.04:06.05 |
Z-Wave Version | 6.51.09 |
Certification ID | ZC10-20106990 |
Z-Wave Product Id | 0x0440.0x0003.0x0071 |
Electric Load Type | Inductive (e.g. Motor) |
Color | Black |
Neutral Wire Required | ok |
Window Covering Control Features | Automatic CalibrationManual CalibrationPosition AwareSupports Horizontal Blinds/LouversSupports Open/Close MotionSupports Tilt MotionSupports Up/Down Motion |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |