Quickstart

This is a On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The ZOE Power H controls on/off function for two electrical devices (door locks, door openers, fans, etc.) or lights. It measures power consumption of the connected device, and can be paired with a digital temperature sensor (sold separately). It supports push-button/momentary switches and toggle switches (default). The connection of a digital temperature sensor means you can create complex scenes and control any device relative to a set temperature range. The ZOE Power H acts as a Z-Wave repeater to improve the range and stability of the Z-Wave network.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Lifeline group (reserved for communication with the main controller), 1 node allowed.
2 16 Basic on/off (triggered at change of the output Q1 state and reflecting its state) up to 16 nodes.
3 16 Switch binary report (triggered at change of the output Q1 state and reflecting its state) up to 16 nodes.
4 16 Power meter report (triggered at change of the output Q1 state) up to 16 nodes
5 16 Basic on/off (triggered at change of the output Q2 state and reflecting its state) up to 16 nodes.
6 16 Switch binary report (triggered at change of the output Q2 state and reflecting its state) up to 16 nodes.
7 16 Power meter report (triggered at change of the output Q2 state) up to 16 nodes.
8 16 Multilevel sensor report (triggered at change of temperature sensor) up to 16 nodes.

Configuration Parameters

Parameter 1: Parameter no. 1Input 1 switch type

Available configuration parameters (data type is 1 Byte DEC):default value 1 0 - mono-stable switch type (push button) 1 - bi-stable switch type
Size: 1 Byte, Default Value: 1

Setting Description
0 mono-stable switch type (push button)
1 bi-stable switch type

Parameter 10: Parameter no. 10 - Activate / deactivate functions ALL ON/ALL OFF

Available configuration parameters (data type is 2 Byte DEC): default value 255 255 - ALL ON active, ALL OFF active. 0 - ALL ON is not active ALL OFF is not active 1 - ALL ON is not active ALL OFF active 2 - ALL ON active ALL OFF is not active Zoe Power module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system.
Size: 2 Byte, Default Value: 255

Setting Description
255 ALL ON active, ALL OFF active
0 ALL ON is not active ALL OFF is not active
1 ALL ON is not active ALL OFF active
2 ALL ON active ALL OFF is not active

Parameter 11: Parameter no. 11 - Automatic turning off output Q1 after set time

When relay Q1 is ON it goes automatically OFF after time defined by this parameter. Timer is reset to zero each time the module receive ON command regardless from where it comes (push button, associated module, controller,..).Available configuration parameters (data type is 2 Byte DEC)default value 0 0 - Auto OFF disabled 1 - 32535 = 1second (0,01s) - 32535 seconds (325.35s) Auto OFF enabled with define time, step is 1s or 10ms according to parameter nr.15.
Size: 2 Byte, Default Value: 0

Setting Description
0 Auto OFF disabled
1 - 32525 1second (0.01s) - 32535 seconds (325.35s) Auto OFF enabled with define time, step is 1s or 10ms according to parameter nr.15.

Parameter 110: Parameter no. 110Temperature sensor offset settings

Set value is added or subtracted to actual measured value by sensor. Available configuration parameters (data type is 2 Byte DEC): default value 32536 32536 - offset is 0.0C From 1 to 100 - value from 0.1 C to 10.0 C is added to actual measured temperature. From 1001 to 1100 - value from -0.1 C to -10.0 C is subtracted to actual measured temperature.
Size: 2 Byte, Default Value: 32526

Setting Description
32526 offset is 0.0C
1 - 100 From 1 to 100 - value from 0.1 C to 10.0 C is added to actual measured temperature.
1001 - 1100 From 1001 to 1100 - value from -0.1 C to -10.0 C is subtracted to actual measured temperature.

Parameter 12: Parameter no. 12 - Automatic turning on output Q1 after set time

When relay Q1 is OFF it goes automatically ON after time defined by this parameter. Timer is reset to zero each time the module receive OFF command regardless from where it comes (push button, associated module, controller,..).Available configuration parameters (data type is 2 Byte DEC):default value 0 0 - Auto ON disabled 1 - 32535 = 1second (0.01s) - 32536 seconds (325.35s) Auto ON enabled with define time, step is 1s or 10ms according to parameter nr.15.
Size: 2 Byte, Default Value: 0

Setting Description
0 Auto ON disabled
1 - 32535 1second (0.01s) - 32536 seconds (325.35s) Auto ON enabled with define time, step is 1s or 10ms according to parameter nr.15.

Parameter 120: Parameter no. 120Temperature sensor reporting

If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. Available configuration parameters (data type is 1 Byte DEC): Default value 5 = 0.5C 0Reporting disabled 1- 127 = 0.1C12.7C, step is 0.1
Size: 1 Byte, Default Value: 0

Setting Description
0 Reporting disabled
1 - 127 0.1C12.7C, step is 0.1C

Parameter 13: Parameter no. 13 - Automatic turning off output Q2 after set time

When relay Q2 is ON it goes automatically OFF after time defined by this parameter. Timer is reset to zero each time the module receive ON command regardless from where it comes (push button, associated module, controller,..).Available configuration parameters (data type is 2 Byte DEC):default value 0 0 - Auto OFF disabled 1 - 32535 = 1second (0.01s) - 32535 seconds (325.35s) Auto OFF enabled with define time, step is 1s or 10ms according to parameter nr.15.
Size: 2 Byte, Default Value: 0

Setting Description
0 Auto OFF disabled
1 - 32535 1second (0.01s) - 32535 seconds (325.35s) Auto OFF enabled with define time, step is 1s or 10ms according to parameter nr.15

Parameter 14: Parameter no. 14 - Automatic turning on output Q2 after set time

When relay Q2 is OFF it goes automatically ON after time defined by this parameter. Timer is reset to zero each time the module receive OFF command regardless from where it comes (push button, associated module, controller,..).Available configuration parameters (data type is 2 Byte DEC):default value 0 0 - Auto ON disabled 1 - 32535 = 1second (0.01s) - 32535 seconds (325.35s) Auto ON enabled with define time, step is 1s or 10ms according to parameter nr.15.
Size: 2 Byte, Default Value: 0

Setting Description
0 Auto ON disabled
1 - 32535 1second (0.01s) - 32535 seconds (325.35s) Auto ON enabled with define time, step is 1s or 10ms according to parameter nr.15.

Parameter 15: Parameter no. 15 - Automatic turning off / on seconds or milliseconds selection

Available configuration parameters (data type is 1 Byte DEC):default value 0 0seconds selected 1milliseconds selected Note that parameter is valid for both outputs Q1, Q2 and is the same for turning off or on.
Size: 1 Byte, Default Value: 0

Setting Description
0 seconds selected
1 milliseconds selected

Parameter 2: Parameter no. 2Input 2 switch type

Available configuration parameters (data type is 1 Byte DEC):default value 1 0 - mono-stable switch type (push button) 1 - bi-stable switch type
Size: 1 Byte, Default Value: 0

Setting Description
0 mono-stable switch type (push button)
1 bi-stable switch type

Parameter 30: Parameter no. 30 - Saving the state of the relays Q1 and Q2 after a power failure

Available configuration parameters (data type is 1 Byte DEC):default value 0 0 - Zoe Power module saves its state before power failure (it returns to the last position saved before a power failure) 1 - Zoe Power module does not save the state after a power failure, it returns to u0022offu0022 position.
Size: 1 Byte, Default Value: 0

Setting Description
0 Zoe Power module saves its statebefore power failure (it returns to the lastposition saved before a power failure)
1 Zoe Power module does not save thestate after a power failure, it returns to u0022offu0022 position

Parameter 40: Parameter no. 40Power reporting in Watts on power change for Q1

Set value means percentage, set value from 0100 = 0% - 100%. Available configuration parameters (data type is 1 Byte DEC):default value 10 0 - reporting disabled 1 - 100 = 1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%.
Size: 1 Byte, Default Value: 10

Setting Description
0 reporting disabled
1 - 100 1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%.

Parameter 41: Parameter no. 41Power reporting in Watts on power change for Q2

Set value means percentage, set value from 0100 = 0% - 100%. Available configuration parameters (data type is 1 Byte DEC):default value 10 0 - Reporting Disabled 1 - 100 = 1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%. NOTE: if power changed is less than 1W, the report is not send (pushed), independent of percentage set.
Size: 1 Byte, Default Value: 10

Setting Description
0 Reporting Disabled
1 - 100 1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%.NOTE: if power changed is less than 1W, the report is not send (pushed), independent of percentage set.

Parameter 42: Parameter no. 42Power reporting in Watts by time interval for Q1

Set value means time interval (032535) in seconds, when power report is send. Available configuration parameters (data type is 2 Byte DEC): default value 300 (power report in Watts is send each 300s) 0 - reporting disabled 1 - 32535 = 1 second - 32535 seconds. Reporting enabled, Power report is send with time interval set by entered value.
Size: 2 Byte, Default Value: 300

Setting Description
0 reporting disabled
1 - 32525 1 second - 32535 seconds. Reporting enabled, Power report is send with time interval set by entered value.

Parameter 43: Parameter no. 43Power reporting in Watts by time interval for Q2

Set value means time interval (032535) in seconds, when power report is send. Available configuration parameters (data type is 2 Byte DEC): default value 300 (power report in Watts is send each 300s) 0 - reporting disabled 1 - 32535 = 1 second - 32535 seconds. Reporting enabled, Power report is send with time interval set by entered value
Size: 2 Byte, Default Value: 300

Setting Description
0 reporting disabled
1 - 32525 1 second - 32535 seconds. Reporting enabled, Power report is send with time interval set by entered value.

Parameter 63: Parameter no. 63Output Q1 Switch selection

Set value means the type of the device that is connected to the Q1 output. The device type can be normally open (NO) or normally close (NC). Available configuration parameters (data type is 1 Byte DEC): default value 0 0 - When system is turned off the output is 0V (NC). 1 - When system is turned off the output is 230V (NO).
Size: 1 Byte, Default Value: 0

Setting Description
0 When system is turned off the output is 0V (NC).
1 When system is turned off the output is 230V (NO).

Parameter 64: Parameter no. 64Output Q2 Switch selection

Set value means the type of the device that is connected to the Q2 output. The device type can be normally open (NO) or normally close (NC). Available configuration parameters (data type is 1 Byte DEC): default value 0 0 - When system is turned off the output is 0V (NC). 1 - When system is turned off the output is 230V (NO).
Size: 1 Byte, Default Value: 0

Setting Description
0 When system is turned off the output is 0V (NC).
1 When system is turned off the output is 230V (NO).

Technical Data

Hardware Platform ZM5202
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 2 FW: 5.01:05.02
Z-Wave Version 6.51.06
Certification ID ZC10-20096969
Z-Wave Product Id 0x0440.0x0002.0x0051
Neutral Wire Required ok
Switch Type
Electric Load Type
Loads Controlled
Color
Frequency XXfrequency
Maximum transmission power XXantenna
On/Off Power Switch