Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The module is mounted via a bracket, it is tamper protected and has a back-up battery.Three Inputs for the connection of: Analogue sensors with voltage 0~12VDigital sensors with voltage 0~12VPotential-free outputs NC/NOOpen Collector Outputs OCThree Outputs for connecting actuators with a maximum of 24VDCSPDT (Single Pole, Double Throw) relay (toggle switch)functions:Configurable timer that automatically switches off after a preset period of time (default is 500 ms)The output can be set to activate automatically when the input terminals (see configuration setting)

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 The Lifeline Association is automatically established between the Z-Wave controller and the device at inclusion and defines what information is exchanged between the Z-Wave controller and the device.
2 5 When a signal input is triggered, the unit first sends a BASIC Set ON. When the preset timer expires, it sends a BASIC Set OFF.
3 5 When a signal input is triggered, the unit first sends a BASIC Set ON. When the preset timer expires, it sends a BASIC Set OFF.
4 5 When a signal input is triggered, the unit first sends a BASIC Set ON. When the preset timer expires, it sends a BASIC Set OFF.

Configuration Parameters

Parameter 1: Signal input 1 - Mode

Several settings of the signal input and its triggering behaviour.
Size: 1 Byte, Default Value: 0

Setting Description
0 No Relay is triggered, No Voltage is present, triggers below lowthreshold
2 - 0 Relay 1 is triggered, No Voltage is present, triggers below lowthreshold
4 - 0 Relay 2 is triggered, No Voltage is present, triggers below lowthreshold
6 - 0 Relay 1 and 2 are triggered, No Voltage is present, triggers below lowthreshold
8 - 0 Relay 3 is triggered, No Voltage is present, triggers below lowthreshold
10 - 0 Relay 1 and 3 are triggered, No Voltage is present, triggers below lowthreshold
14 - 0 Relay 1, 2 and 3 are triggered, No Voltage is present, triggers below lowthreshold
64 - 0 No Relay is triggered, 3,3V is present, triggers below lowthreshold
66 - 0 Relay 1 is triggered, 3,3V is present, triggers below lowthreshold
68 - 0 Relay 2 is triggered, 3,3V is present, triggers below lowthreshold
70 - 0 Relay 1 and 2 are triggered, 3,3V is present, triggers below lowthreshold
72 - 0 Relay 3 is triggered, 3,3V is present, triggers below lowthreshold
74 - 0 Relay 1 and 3 are triggered, 3,3V is present, triggers below lowthreshold
78 - 0 Relay 1, 2 and 3 are triggered, 3,3V is present, triggers below lowthreshold
128 - 0 No Relay is triggered, No Voltage is present, triggers above highthreshold
130 - 0 Relay 1 is triggered, No Voltage is present, triggers above highthreshold
132 - 0 Relay 2 is triggered, No Voltage is present, triggers above highthreshold
134 - 0 Relay 1 and 2 are triggered, No Voltage is present, triggers above highthreshold
136 - 0 Relay 3 is triggered, No Voltage is present, triggers above highthreshold
138 - 0 Relay 1 and 3 are triggered, No Voltage is present, triggers above highthreshold
142 - 0 Relay 1, 2 and 3 are triggered, No Voltage is present, triggers above highthreshold
192 - 0 No Relay is triggered, 3,3V is present, triggers above highthreshold
194 - 0 Relay 1 is triggered, 3,3V is present, triggers above highthreshold
196 - 0 Relay 2 is triggered, 3,3V is present, triggers above highthreshold
198 - 0 Relay 1 and 2 are triggered, 3,3V is present, triggers above highthreshold
200 - 0 Relay 3 is triggered, 3,3V is present, triggers above highthreshold
202 - 0 Relay 1 and 3 are triggered, 3,3V is present, triggers above highthreshold
206 - 0 Relay 1, 2 and 3 are triggered, 3,3V is present, triggers above highthreshold
12 - 0 Relay 2 and 3 are triggered, No Voltage is present, triggers below lowthreshold
76 - 0 Relay 2 and 3 are triggered, 3,3V is present, triggers below lowthreshold
140 - 0 Relay 2 and 3 are triggered, No Voltage is present, triggers above highthreshold
204 - 0 Relay 2 and 3 are triggered, 3,3V is present, triggers above highthreshold

Parameter 10: Signal input 2 - voltage low-threshold

Setting of the voltage drop below which the signal input is triggered
Size: 1 Byte, Default Value: 10

Setting Description
0 - 255 Adjustable from 0 - 255 in 100mV steps (10 = 1000mV = 1.0V)

Parameter 11: Signal input 3 - Mode

Same as Parameter 1, but applies to Signal Input 3
Size: 1 Byte, Default Value: 64

Setting Description
0 No Relay is triggered, No Voltage is present, triggers below lowthreshold
2 - 0 Relay 1 is triggered, No Voltage is present, triggers below lowthreshold
4 - 0 Relay 2 is triggered, No Voltage is present, triggers below lowthreshold
6 - 0 Relay 1 and 2 are triggered, No Voltage is present, triggers below lowthreshold
8 - 0 Relay 3 is triggered, No Voltage is present, triggers below lowthreshold
10 - 0 Relay 1 and 3 are triggered, No Voltage is present, triggers below lowthreshold
12 - 0 Relay 2 and 3 are triggered, No Voltage is present, triggers below lowthreshold
14 - 0 Relay 1, 2 and 3 are triggered, No Voltage is present, triggers below lowthreshold
64 - 0 No Relay is triggered, 3,3V is present, triggers below lowthreshold
66 - 0 Relay 1 is triggered, 3,3V is present, triggers below lowthreshold
68 - 0 Relay 2 is triggered, 3,3V is present, triggers below lowthreshold
70 - 0 Relay 1 and 2 are triggered, 3,3V is present, triggers below lowthreshold
72 - 0 Relay 3 is triggered, 3,3V is present, triggers below lowthreshold
74 - 0 Relay 1 and 3 are triggered, 3,3V is present, triggers below lowthreshold
76 - 0 Relay 2 and 3 are triggered, 3,3V is present, triggers below lowthreshold
78 - 0 Relay 1, 2 and 3 are triggered, 3,3V is present, triggers below lowthreshold
128 - 0 No Relay is triggered, No Voltage is present, triggers above highthreshold
130 - 0 Relay 1 is triggered, No Voltage is present, triggers above highthreshold
132 - 0 Relay 2 is triggered, No Voltage is present, triggers above highthreshold
134 - 0 Relay 1 and 2 are triggered, No Voltage is present, triggers above highthreshold
136 - 0 Relay 3 is triggered, No Voltage is present, triggers above highthreshold
138 - 0 Relay 1 and 3 are triggered, No Voltage is present, triggers above highthreshold
140 - 0 Relay 2 and 3 are triggered, No Voltage is present, triggers above highthreshold
142 - 0 Relay 1, 2 and 3 are triggered, No Voltage is present, triggers above highthreshold
192 - 0 No Relay is triggered, 3,3V is present, triggers above highthreshold
194 - 0 Relay 1 is triggered, 3,3V is present, triggers above highthreshold
196 - 0 Relay 2 is triggered, 3,3V is present, triggers above highthreshold
198 - 0 Relay 1 and 2 are triggered, 3,3V is present, triggers above highthreshold
200 - 0 Relay 3 is triggered, 3,3V is present, triggers above highthreshold
202 - 0 Relay 1 and 3 are triggered, 3,3V is present, triggers above highthreshold
204 - 0 Relay 2 and 3 are triggered, 3,3V is present, triggers above highthreshold
206 - 0 Relay 1, 2 and 3 are triggered, 3,3V is present, triggers above highthreshold

Parameter 12: Relay output 3 - switching time

Setting for the duration of the switching time when the relay output is switched.
Size: 1 Byte, Default Value: 5

Setting Description
0 relay output is permanently switched
1 - 255 Adjustable duration from 1 - 255 in 100ms steps

Parameter 13: Signal input 3 - switching time at association group 4

Setting for the duration of the switching time at association group 4 when signal input is triggered.
Size: 1 Byte, Default Value: 180

Setting Description
0 Switched permanently
1 - 255 Adjustable duration from 1 - 255 in seconds

Parameter 14: Signal input 3 - voltage high-threshold

Setting, from which voltage rise the signal input is triggered
Size: 1 Byte, Default Value: 25

Setting Description
0 - 255 Adjustable from 0 - 255 in 100mV steps (25 = 2500mV = 2.5V)

Parameter 15: Signal input 3 - voltage low-threshold

Setting of the voltage drop below which the signal input is triggered
Size: 1 Byte, Default Value: 10

Setting Description
0 - 255 Adjustable from 0 - 255 in 100mV steps (10 = 1000mV = 1.0V)

Parameter 16: Voltage Report (time)

The interval time of the voltage report for signal input 1-3
Size: 1 Byte, Default Value: 30

Setting Description
1 - 255 Adjustable from 1 - 255 in minutes

Parameter 17: Sabotage Alarm Relay output

Setting whether a relay output must be switched in case of a sabotage alarm.
Size: 1 Byte, Default Value: 0

Setting Description
0 No Relays are triggered
2 - 0 Relay 1 is triggered
4 - 0 Relay 2 is triggered
6 - 0 Relay 1 and 2 are triggered
8 - 0 Relay 3 is triggered
10 - 0 Relay 1 and 3 are triggered
12 - 0 Relay 2 and 3 are triggered
14 - 0 Relay 1, 2 and 3 are triggered

Parameter 18: Signal input - Activate arm / disarm message

Setting whether a signal input should send an armed and an unarmed message instead of a trigger signal.
Size: 1 Byte, Default Value: 0

Setting Description
0 0 = No signal input sends arm/disarm message
1 1 = Signal input 1 sends arm/disarm message
2 2 = Signal input 2 sends arm/disarm message
3 3 = Signal input 3 sends arm/disarm message

Parameter 2: Relay output 1 - switching time

Setting for the duration of the switching time when the relay output is switched.
Size: 1 Byte, Default Value: 5

Setting Description
0 relay output is permanently switched
1 - 255 Adjustable duration from 1 - 255 in 100ms steps

Parameter 3: Signal input 1 - switching time at association group 2

Setting for the duration of the switching time at association group 2 when signal input is triggered.
Size: 1 Byte, Default Value: 180

Setting Description
0 Switched permanently
1 - 255 Adjustable duration from 1 - 255 in seconds

Parameter 4: Signal input 1 - voltage high-threshold

Setting, from which voltage rise the signal input is triggered
Size: 1 Byte, Default Value: 25

Setting Description
0 - 255 Adjustable from 0 - 255 in 100mV steps (25 = 2500mV = 2.5V)

Parameter 5: Signal input 1 - voltage low-threshold

Setting of the voltage drop below which the signal input is triggered
Size: 1 Byte, Default Value: 10

Setting Description
0 - 255 Adjustable from 0 - 255 in 100mV steps (10 = 1000mV = 1.0V)

Parameter 6: Signal input 2 - Mode

Same as Parameter 1, but applies to Signal Input 2
Size: 1 Byte, Default Value: 64

Setting Description
0 No Relay is triggered, No Voltage is present, triggers below lowthreshold
2 - 0 Relay 1 is triggered, No Voltage is present, triggers below lowthreshold
4 - 0 Relay 2 is triggered, No Voltage is present, triggers below lowthreshold
6 - 0 Relay 1 and 2 are triggered, No Voltage is present, triggers below lowthreshold
8 - 0 Relay 3 is triggered, No Voltage is present, triggers below lowthreshold
10 - 0 Relay 1 and 3 are triggered, No Voltage is present, triggers below lowthreshold
12 - 0 Relay 2 and 3 are triggered, No Voltage is present, triggers below lowthreshold
14 - 0 Relay 1, 2 and 3 are triggered, No Voltage is present, triggers below lowthreshold
64 - 0 No Relay is triggered, 3,3V is present, triggers below lowthreshold
66 - 0 Relay 1 is triggered, 3,3V is present, triggers below lowthreshold
68 - 0 Relay 2 is triggered, 3,3V is present, triggers below lowthreshold
70 - 0 Relay 1 and 2 are triggered, 3,3V is present, triggers below lowthreshold
72 - 0 Relay 3 is triggered, 3,3V is present, triggers below lowthreshold
74 - 0 Relay 1 and 3 are triggered, 3,3V is present, triggers below lowthreshold
76 - 0 Relay 2 and 3 are triggered, 3,3V is present, triggers below lowthreshold
78 - 0 Relay 1, 2 and 3 are triggered, 3,3V is present, triggers below lowthreshold
128 - 0 No Relay is triggered, No Voltage is present, triggers above highthreshold
130 - 0 Relay 1 is triggered, No Voltage is present, triggers above highthreshold
132 - 0 Relay 2 is triggered, No Voltage is present, triggers above highthreshold
134 - 0 Relay 1 and 2 are triggered, No Voltage is present, triggers above highthreshold
136 - 0 Relay 3 is triggered, No Voltage is present, triggers above highthreshold
138 - 0 Relay 1 and 3 are triggered, No Voltage is present, triggers above highthreshold
140 - 0 Relay 2 and 3 are triggered, No Voltage is present, triggers above highthreshold
142 - 0 Relay 1, 2 and 3 are triggered, No Voltage is present, triggers above highthreshold
192 - 0 No Relay is triggered, 3,3V is present, triggers above highthreshold
194 - 0 Relay 1 is triggered, 3,3V is present, triggers above highthreshold
196 - 0 Relay 2 is triggered, 3,3V is present, triggers above highthreshold
198 - 0 Relay 1 and 2 are triggered, 3,3V is present, triggers above highthreshold
200 - 0 Relay 3 is triggered, 3,3V is present, triggers above highthreshold
202 - 0 Relay 1 and 3 are triggered, 3,3V is present, triggers above highthreshold
204 - 0 Relay 2 and 3 are triggered, 3,3V is present, triggers above highthreshold
206 - 0 Relay 1, 2 and 3 are triggered, 3,3V is present, triggers above highthreshold

Parameter 7: Relay output 2 - switching time

Setting for the duration of the switching time when the relay output is switched.
Size: 1 Byte, Default Value: 5

Setting Description
0 relay output is permanently switched
1 - 255 Adjustable duration from 1 - 255 in 100ms steps

Parameter 8: Signal input 2 - switching time at association group 3

Setting for the duration of the switching time at association group 3 when signal input is triggered.
Size: 1 Byte, Default Value: 180

Setting Description
0 Switched permanently
1 - 255 Adjustable duration from 1 - 255 in seconds

Parameter 9: Signal input 2 - voltage high-threshold

Setting, from which voltage rise the signal input is triggered
Size: 1 Byte, Default Value: 25

Setting Description
0 - 255 Adjustable from 0 - 255 in 100mV steps (25 = 2500mV = 2.5V)

Technical Data

Hardware Platform SD3502
Device Type Notification Sensor
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.00:00.04
Z-Wave Version 6.81.06
Certification ID ZC10-20076949
Z-Wave Product Id 0x0403.0x0003.0x0007
Frequency XXfrequency
Maximum transmission power XXantenna
Notification Sensor