Quickstart

This is a secure On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

Smart Plug is a Z-Wave Switch plugin module specifically used to enable Z-Wave command and control (on/off) of any plug-in tool. It can report wattage consumption or kWh energy usage. This device is a security enabled Z-Wave Plus product that is able to use encrypted Z-Wave Plus messages to communicate to other security enabled Z-Wave Plus products.Smart Plug is also a security Z-Wave device and supports the Over The Air (OTA) feature for the products firmware upgrade.This device must be used in conjunction with a Security Enabled Z-Wave Controller in order to fully utilize all implemented functions.Features:1) AC output switch on/off by manual or Z-Wave command;2) RGB LED indicates the Z-WAVE network range and load power;3) Support S0 and S2 security network;4) Supporting power meter;5) Supporting repeater role;6) Supporting firmware OTA;7) Supporting Smart Start;8) Supports over-current protection

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus Lifeline

Configuration Parameters

Parameter 151: Threshold of power report

Power threshold to be interpreted, when the change value of load power exceeds the setting threshold, the smart plug will send meter report to association device (Group Lifeline).
Size: 2 Byte, Default Value: 50

Setting Description
0 - 200 Available settings: 0 - 200 (0 - 200W)
0 0 - The function is disabled.

Parameter 152: Percentage threshold of power report

Power percentage threshold to be interpreted, when change value of the load power exceeds the setting threshold, the smart plug will send meter report to association device (Group Lifeline).
Size: 1 Byte, Default Value: 10

Setting Description
0 The function is disabled.
1 - 100 Available settings: 1- 100 (0 - 100%)

Parameter 171: Power report frequency

The interval of sending power report to association device (Group Lifeline).
Size: 4 Byte, Default Value: 3600

Setting Description
0 The function is disabled.
3600 - 2678400 Available settings: 3600- 2678400 (3600 - 2678400s)

Parameter 172: Energy report frequency

The interval of sending energy report to association device (Group Lifeline).
Size: 4 Byte, Default Value: 7200

Setting Description
0 The function is disabled.
3600 - 2678400 Available settings: 3600- 2678400 (3600 - 2678400s)

Parameter 173: Voltage report frequency

The interval of sending voltage report to association device (Group Lifeline).
Size: 4 Byte, Default Value: 7200

Setting Description
0 The function is disabled.
3600 - 2678400 Available settings: 3600- 2678400 (3600 - 2678400s)

Parameter 174: Electricity report frequency

The interval of sending electricity report to association device (Group Lifeline).
Size: 4 Byte, Default Value: 7200

Setting Description
0 The function is disabled.
3600 - 2678400 Available settings: 3600- 2678400 (3600 - 2678400s)

Parameter 20: Overload protection

Smart Plug keep detecting the load power, once the AC current exceeds 11.5A for more than 5s, smart plug's relay will turn off.
Size: 1 Byte, Default Value: 1

Setting Description
0 The function is disabled
1 The function is enabled.

Parameter 21: Setting device status after power failure

Define how the Plug reacts after the power supply is back on.
Size: 1 Byte, Default Value: 0

Setting Description
0 Smart Plug memorizes its state after a power failure.
1 Smart Plug does not memorize its state after a power failure. Connected device will be on after the power supply is reconnected.
2 Smart Plug does not memorize its state after a power failure. Connected device will be off after the power supply is reconnected.

Parameter 24: Notification when Load status change

Smart Plug can send notifications to association device (Group Lifeline) when state of smart plugs load change.
Size: 1 Byte, Default Value: 1

Setting Description
0 The function is disabled.
1 Send Basic report.
2 Send Basic report only when Load condition is not changed by Z-WAVE Command.

Parameter 254: Enable/disable the configuration command

Lock/unlock all configuration parameters.
Size: 1 Byte, Default Value: 0

Setting Description
0 Unlock
1 Lock

Parameter 27: Indicator modes

After smart plug being included into a Z-Wave network, the RGB LED indicator will indicator the situation of load.
Size: 1 Byte, Default Value: 0

Setting Description
0 The indicator light remains the same as the load on/off status. When the load is on, the light is on, and the off is off.
1 Within 5 seconds after the operation load, the indicator light is consistent with the load on/off status, and then the indicator is off.

Technical Data

Hardware Platform ZM5202
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.02
Z-Wave Version 6.81.01
Certification ID ZC10-20076940
Z-Wave Product Id 0x0208.0x0100.0x0019
Electric Load Type
Communications Protocol Manufacturer Proprietary Protocol
Firmware Updatable Not Updatable
Switch Type Decorator Paddle Push
Color Antique Brass
Supported Meter Type
Frequency XXfrequency
Maximum transmission power XXantenna
On/Off Power Switch