This is a
Flood Sensor is capable of both detecting leaks and floods and when the level of water gets too low in pool or tank, Flood Sensor can work with your Z-Wave network to prevent emergencies such as burst water boiler to leaking air conditioners. With Z-Wave, the scope to save money is endless.The features list:1)Z-Wave Plus certified for wide compatibility (500 serials product).2)Security 0 and Security 2 framework implemented with AES-128 encryption.3)Contains an extension water detecting probe. 4)Temperature measurement.5)Vibration sensor.6)The battery life is up to 1 year. 7)Low battery alert
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Association Group 1 is the lifeline group |
2 | 5 | 1. Basic Set.Flood Sensor will send Basic Set to associated nodes whenWater leak detected. |
Flood sensor can send BASIC SET command to nodes associated with group 2. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
Flood sensor can reverse its value of BASIC SET when flooding is triggered. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Send BASIC SET VALUE = 255 to nodes associated with group 2 when flooding alarm is triggered.Send BASIC SET VALUE = 0 to nodes associated with group 2 when flooding alarm is canceled. |
1 | Send BASIC SET VALUE = 0 to nodes associated with group 2 when flooding alarm is triggered.Send BASIC SET VALUE = 255 to nodes associated with group 2 when flooding alarm is canceled. |
Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
1 - 240 | The higher the value, the long the report periodically - in hexadecimal values from 0x01 to 0xFF, or 1 to 255 if your controller allows unsigned decimal values. |
0 | Disable flooding alarm |
Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | when the value is 0, the product will not sends a vibration alarm after moving or shaking; |
1 | when the value is 1, the product will sends a vibration alarm after moving or shaking |
The temperature changes at least 1 degree Celsius before reported. Size: 1 Byte, Default Value: 240
Setting | Description |
---|---|
30 - 240 | the higher the value ,the long the report time |
The precision of the temperature value is 1.Available settings(US):-670 - 2570-67257FAvailable settings(Other):-550 - 1250-55125CDefault setting (US): 1040 (104F)Default setting (Other): 400(40C) Size: 2 Byte, Default Value: 1040
Setting | Description |
---|---|
-670 - 2570 | the larger the value , the higher the high temperature(US) |
-550 - 1250 | the larger the value , the higher the high temperature(other) |
The precision of the temperature value is 1.Available settings(US):-670 - 2570-67257FAvailable settings(Other):-550 - 1250-55125CDefault setting (US): 320 (32F)Default setting (Other): 0 (0C) Size: 2 Byte, Default Value: 320
Setting | Description |
---|---|
-670 - 2570 | the smaller the value , the lower the low temperature(US) |
-550 - 1250 | the smaller the value , the lower the low temperature(other) |
0 Disable.1 Enable. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | when the value is 0, the product will not blink LED when being triggered; |
1 | when the value is 1, the product will blink LED when being triggered |
This parameter defines a battery level as the low battery.Available settings: 10-50 (10% - 50%)Default setting: 20 (20%) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
10 - 50 | Set the trigger value for the low battery alarm |
Hardware Platform | ZM5202 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 1 FW: 1.01 |
Z-Wave Version | 6.71.01 |
Certification ID | ZC10-20076939 |
Z-Wave Product Id | 0x0208.0x0200.0x000F |
Color | Antique Brass |
Supported Notification Types | |
Firmware Updatable | Not Updatable |
Sensors | |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |